Specificaon
H2
H1
H3
H4
H5
H1 - Pulse Count
H2 - Pulse Count
H3 - LED
H4 - Sensivity
H5 - Latch
3.2
3.3
3.4
3.5
Material Concrete Wood Fixed Window Frame
1.0m 2.5m 2.5m
H1
H2
H3
H4
H5
H1
H2
H3
H4
H5
Remove the jumper from the H5 (or put on just one pin so that the jumper is
not lost) to acvate the latching feature. If this feature is acvated and the
sensor is triggered, the LED on the sensor will stay on in order to display that it
has been acvated. To reset, the power must be removed from the device.
If the sensor detects “gross aack” (a vibraon higher than the calibrated sensivity), it will
override the pulse count and go directly into alarm.
108mm
30mm 22mm
37.5g
3.2 Sengs - Pluse Count
3.4 Sengs - Sensivity 3.5 Sengs - Latch 4 Wiring
Dimension
3.3 Sengs - LED
2 Installaon1 Component 3.1 Sengs - Jumper
Note: The stated values are typical. It is advised that
practical testing is performed before installation to verify
the operation. In some environments, these values may
differ from stated.
H1
H2
H3
H4
H5
Each me the pulse count seng is changed, the LED will flash the appropriate number of mes
to indicate which seng is selected. It will verify this by indicang the pulse count seng 3
mes, pausing between each verificaon.
a. Screw Cover d. Light Pipe
e. PCB
b. Screw
f. Rear Panel
Wired Shock Detector
0s
0s
0s
0s
0.5s
0.5s
0.5s
0.5s
1s
1s
1s
1s
1.5s
1.5s
1.5s
1.5s
2s
2s
2s
2s
a. Powering up
b. Vibraon detected
c. Device triggered
d. Gross acvaon
Flash on and off
Flash once
Flash once → Off
Flash once → Latch (Remove H5)
Flash once → Off
Flash once → Stay on (Remove H5)
LED
a. High Sensivity b. Low Sensivity c. Increase d. Decrease
Material and Mounng Posion
H1
H2
H3
H4
H5
Pluse Count
H1 H2 Pluse
1
2
4
6
a. Alarm Control Panel
b. Sensor
(1) Normally Closed
ZONE2
COM
ZONE1
COM
+-
TAMPER ALARM - +
(2) Double End of Line Wiring a. Alarm Control Panel
b. Sensor
Wiring Example:
1. Normal: 2.2 K
2. Alarm: 4.4 k
3. Tamper: Infinite
ZONE2
COM
ZONE1
COM
+-
TAMPER ALARM - +
1
34
2
UD21449B
c. Front Panel
2.2K 2.2K
Sensor Piezoelectric sensor
Sensi itv y Potenometer Adjustment
T pam er switch Support
I gntelli ent algorithm Support
Alarm out ut ormall closedp N y
LED Blue (alarm)
Nominal olta e 9 to 16 VDCv g
Nominal current 30 mA
Stora e temg perature -20 °C to 60 °C -4 °F to 140 °F)(
Op era ng temperature -10 °C to 55 °C 14 °F to 131 °F)(
Op era ng humidit 10% to 90%y
I nstalla on Wall-mounng
Dimension 108 mm × 30 mm × 22 mm
Wei ht 37.5g g
FCC statements: This device complies with part 15 of the FCC Rules.Operaon is subject to the following
two condions:(1)this device may not cause harmful interface,and (2)this device must accept any
interference received,including interference that may cause undesired operaon
FCC Informaon
Please take aenon that changes or modificaon not expressly approved by the party responsible for compliance could
void the user’s authority to operate the equipment.
FCC compliance: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant
to part 15 of the FCC Rules. These limits are designed to provide reasonable protecon against harmful interference in a
residenal installaon. This equipment generates, uses and can radiate radio frequency energy and, if not installed and
used in accordance with the instrucons, may cause harmful interference to radio communicaons. However, there is no
guarantee that interference will not occur in a parcular installaon. If this equipment does cause harmful interference to
radio or television recepon, which can be determined by turning the equipment off and on, the user is encouraged to try
to correct the interference by one or more of the following measures:
—Reorient or relocate the receiving antenna.
—Increase the separaon between the equipment and receiver.
—Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
—Consult the dealer or an experienced radio/TV technician for help
FCC Condions
This device complies with part 15 of the FCC Rules. Operaon is subject to the following two condions:
1. This device may not cause harmful interference.
2. This device must accept any interference received, including interference that may cause undesired operaon.


Produkt Specifikationer

Mærke: Hikvision
Kategori: Alarmsystem
Model: DS-PDSK-P

Har du brug for hjælp?

Hvis du har brug for hjælp til Hikvision DS-PDSK-P stil et spørgsmål nedenfor, og andre brugere vil svare dig




Alarmsystem Hikvision Manualer

Alarmsystem Manualer

Nyeste Alarmsystem Manualer