Specificaon
H2
H1
H3
H4
H5
H1 - Pulse Count
H2 - Pulse Count
H3 - LED
H4 - Sensivity
H5 - Latch
3.2
3.3
3.4
3.5
Material Concrete Wood Fixed Window Frame
1.0m 2.5m 2.5m
H1
H2
H3
H4
H5
H1
H2
H3
H4
H5
Remove the jumper from the H5 (or put on just one pin so that the jumper is
not lost) to acvate the latching feature. If this feature is acvated and the
sensor is triggered, the LED on the sensor will stay on in order to display that it
has been acvated. To reset, the power must be removed from the device.
If the sensor detects “gross aack” (a vibraon higher than the calibrated sensivity), it will
override the pulse count and go directly into alarm.
108mm
30mm 22mm
37.5g
3.2 Sengs - Pluse Count
3.4 Sengs - Sensivity 3.5 Sengs - Latch 4 Wiring
Dimension
3.3 Sengs - LED
2 Installaon1 Component 3.1 Sengs - Jumper
Note: The stated values are typical. It is advised that
practical testing is performed before installation to verify
the operation. In some environments, these values may
differ from stated.
H1
H2
H3
H4
H5
Each me the pulse count seng is changed, the LED will flash the appropriate number of mes
to indicate which seng is selected. It will verify this by indicang the pulse count seng 3
mes, pausing between each verificaon.
a. Screw Cover d. Light Pipe
e. PCB
b. Screw
f. Rear Panel
Wired Shock Detector
0s
0s
0s
0s
0.5s
0.5s
0.5s
0.5s
1s
1s
1s
1s
1.5s
1.5s
1.5s
1.5s
2s
2s
2s
2s
a. Powering up
b. Vibraon detected
c. Device triggered
d. Gross acvaon
Flash on and off
Flash once
Flash once → Off
Flash once → Latch (Remove H5)
Flash once → Off
Flash once → Stay on (Remove H5)
LED
a. High Sensivity b. Low Sensivity c. Increase d. Decrease
Material and Mounng Posion
H1
H2
H3
H4
H5
Pluse Count
H1 H2 Pluse
1
2
4
6
a. Alarm Control Panel
b. Sensor
(1) Normally Closed
ZONE2
COM
ZONE1
COM
+-
TAMPER ALARM - +
(2) Double End of Line Wiring a. Alarm Control Panel
b. Sensor
Wiring Example:
1. Normal: 2.2 K
2. Alarm: 4.4 k
3. Tamper: Infinite
ZONE2
COM
ZONE1
COM
+-
TAMPER ALARM - +
1
34
2
UD21449B
c. Front Panel
2.2K 2.2K
Sensor Piezoelectric sensor
Sensi itv y Potenometer Adjustment
T pam er switch Support
I gntelli ent algorithm Support
Alarm out ut ormall closedp N y
LED Blue (alarm)
Nominal olta e 9 to 16 VDCv g
Nominal current 30 mA
Stora e temg perature -20 °C to 60 °C -4 °F to 140 °F)(
Op era ng temperature -10 °C to 55 °C 14 °F to 131 °F)(
Op era ng humidit 10% to 90%y
I nstalla on Wall-mounng
Dimension 108 mm × 30 mm × 22 mm
Wei ht 37.5g g
FCC statements: This device complies with part 15 of the FCC Rules.Operaon is subject to the following
two condions:(1)this device may not cause harmful interface,and (2)this device must accept any
interference received,including interference that may cause undesired operaon
FCC Informaon
Please take aenon that changes or modificaon not expressly approved by the party responsible for compliance could
void the user’s authority to operate the equipment.
FCC compliance: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant
to part 15 of the FCC Rules. These limits are designed to provide reasonable protecon against harmful interference in a
residenal installaon. This equipment generates, uses and can radiate radio frequency energy and, if not installed and
used in accordance with the instrucons, may cause harmful interference to radio communicaons. However, there is no
guarantee that interference will not occur in a parcular installaon. If this equipment does cause harmful interference to
radio or television recepon, which can be determined by turning the equipment off and on, the user is encouraged to try
to correct the interference by one or more of the following measures:
—Reorient or relocate the receiving antenna.
—Increase the separaon between the equipment and receiver.
—Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
—Consult the dealer or an experienced radio/TV technician for help
FCC Condions
This device complies with part 15 of the FCC Rules. Operaon is subject to the following two condions:
1. This device may not cause harmful interference.
2. This device must accept any interference received, including interference that may cause undesired operaon.
Produkt Specifikationer
Mærke: | Hikvision |
Kategori: | Alarmsystem |
Model: | DS-PDSK-P |
Har du brug for hjælp?
Hvis du har brug for hjælp til Hikvision DS-PDSK-P stil et spørgsmål nedenfor, og andre brugere vil svare dig
Alarmsystem Hikvision Manualer
2 September 2024
2 September 2024
31 August 2024
23 August 2024
23 August 2024
23 August 2024
23 August 2024
23 August 2024
23 August 2024
23 August 2024
Alarmsystem Manualer
- Alarmsystem Ikea
- Alarmsystem Bosch
- Alarmsystem Hager
- Alarmsystem Doro
- Alarmsystem Gigaset
- Alarmsystem Pyle
- Alarmsystem Kodak
- Alarmsystem Nedis
- Alarmsystem Abus
- Alarmsystem Hama
- Alarmsystem Burg Wächter
- Alarmsystem Smartwares
- Alarmsystem Dometic
- Alarmsystem Blaupunkt
- Alarmsystem Honeywell
- Alarmsystem Vivanco
- Alarmsystem EZVIZ
- Alarmsystem König
- Alarmsystem FireAngel
- Alarmsystem Redmond
- Alarmsystem Elro
- Alarmsystem Yale
- Alarmsystem Olympia
- Alarmsystem Techly
- Alarmsystem Basetech
- Alarmsystem Imou
- Alarmsystem APC
- Alarmsystem Olymp
- Alarmsystem Velleman
- Alarmsystem Swann
- Alarmsystem ORNO
- Alarmsystem Eufy
- Alarmsystem Ring
- Alarmsystem M-e
- Alarmsystem Somfy
- Alarmsystem Monacor
- Alarmsystem Brennenstuhl
- Alarmsystem Renkforce
- Alarmsystem Electia
- Alarmsystem Pentatech
- Alarmsystem Eminent
- Alarmsystem Evolveo
- Alarmsystem Vimar
- Alarmsystem Dahua Technology
- Alarmsystem Chacon
- Alarmsystem FBT
- Alarmsystem Kemo
- Alarmsystem Schwaiger
- Alarmsystem Steren
- Alarmsystem Bearware
- Alarmsystem KlikaanKlikuit
- Alarmsystem DESQ
- Alarmsystem Xavax
- Alarmsystem X4-Tech
- Alarmsystem DSC
- Alarmsystem Chuango
- Alarmsystem ETiger
- Alarmsystem Tzumi
- Alarmsystem Woonveilig
- Alarmsystem ConiuGo
- Alarmsystem Schabus
- Alarmsystem Cordes
- Alarmsystem Protector
- Alarmsystem Qolsys
Nyeste Alarmsystem Manualer
2 Oktober 2024
30 September 2024
29 September 2024
29 September 2024
29 September 2024
29 September 2024
29 September 2024
29 September 2024
29 September 2024
29 September 2024