Hikvision DS-PM1-I8O2-H Manual

Hikvision Alarmsystem DS-PM1-I8O2-H

Læs nedenfor 📖 manual på dansk for Hikvision DS-PM1-I8O2-H (6 sider) i kategorien Alarmsystem. Denne guide var nyttig for 9 personer og blev bedømt med 4.5 stjerner i gennemsnit af 2 brugere

Side 1/6
LED TAMPER ALARM FAULT
EOL EOL EOL
Z2 COM Z1
RT RA RF
Tamper Open
Open
Open
Open
Open 4.2KΩ
3.2KΩ
1KΩ
2KΩ
End resistance of the entire circuit is 0Ω.
Close
Close
CloseClose
Close
Close
Close Close
Close
Close
Normal
Alarm
Fault
Masking
Short Circuit
Circuit Resistance
Detector Status RT RA RF
3
1
E N G L I S H
Specication
Component
Indicator
Address Setting
Configure the address via DIP switch of the input module before powering on the system. The address
should be in the range (0 to 63). The address of each module should be unique.
The binary value shown in the diagram is 000011, which means the decimal value is 3, so the address of
the module is 3.
Configuration
Enter the control panel IP address to log in the web client.
Click . You can edit the module name and enable/disable auxiliary power output.Device -> Module
2
4
5
Slowly flashing light green:
Waiting for enrollment
Quickly flashing orange:
Alarm
Slowly flashing green:
Find me mode
Solid green: Enrolled
Alarm input 8
Bus 2 × Speed-X bus (high-speed), 1 input for control panel
connection and 1 output for expander cascading
Power supply 9 to 15 VDC
Quiescent current 45 mA@12 VDC;
Output Current Maximum 500 mA
Operation humidity 10% to 90%
Dimension (W×H×D) 110 mm × 155 mm × 32 mm
Weight 253 g
IO Output 2 (collector outputs, used as control signal of relay
module)
Tamper-Proof Support (front and rear)
Maximum current 119 mA@12 VDC;
Output Voltage 9 to 15 VDC (Same voltage as power supply)
Operation temperature -10°C to 40°C
Shell material Plastic
Power consumption
Green and orange flashing alternately:
Enrolling
Solid orange:
Enrolling failed/Fault (Disconnected)
1
Installation
Wiring (EOL=End of Line)
A. Resistors for NO/NC/Single EOL/Double EOL: 1K, 2.2K, 4.7K, 5.6K, 6.8K, 8.2K
B. Triple EOL Wiring Method: Resistor of Tamper (RT): 1kΩ
Resistor of Alarm (RA): 1kΩ
Resistor of Fault/Masking (RF): 2.2kΩ
a. Input Module
b. Detector
Hangzhou Hikvision Digital Technology CO.,Ltd. No.555 Qianmo Road, Binjiang District, Hangzhou 310052, China
12
3
4
Input Module
DS-PM1-I8O2-H
User Manual
UD26882B-E
EN 50131-1:2006+A1:2009+A2:2017
EN 50131-5-3:2017
EN 50131-3:2009
Security Grade 2
Environment Class II
Z1 COM Z2 Z3 COM Z4 Z5 COM Z6 Z7 COM Z8
D- D+
BUS_OUT AUX 12VDC_INBUS_IN
D- D+ - + - +
COM OC_2 COM OC_1
Z1 COM Z2 Z4COMZ3 Z5 COM Z6 Z7 COM Z8
+ -
N.C Tamper Tamper
Tamper Tamper
N.O
2K2
EOL
Single
EOL
Double
EOL
Double
Zone
2K2
2K2
+ + - + + - +
2K2
EOL N.C N.O
N.O N.C
N.O
N.C
N.C N.O
2K2
2K2
8K2 8K2
2K2
EOL 2K2
EOL
1
1 2
Screw: SC-KM3×9L3-SUS
Screw: PA3×25
BA
BIN Address BIN Address
000001 1 111000 56
000010 2 111001 57
000011 3 111010 58
000100 4 111011 59
000101 5 111100 60
000110 6 111101 61
000111 7 111110 62
111111 63
Lowbit Highbit
BIN=0 00011 Address =3
D- D- COM COM - -D+ D+ OC_2 OC_1 + +
BUS_OUT BUS_IN AUX
RELAYRELAY DC 12V
POWER
12VDC_IN
...
...
...
...... ...
...
...
......
...
...
...
......
...
...
...
......
Speed-X BUS
CONTROL
PANEL
BUS_IN
BUS_IN
BUS_IN
BUS_OUT
BUS_OUT
...MAX. 7...
BUS_OUT
Speed-X BUS
WIRED INPUT
EXPANDER
WIRED INPUT
EXPANDER
WIRED INPUT
EXPANDER
CONTROL
PANEL
BUS_IN
BUS_OUT
WIRED INPUT
EXPANDER
BUS_IN
BUS_OUT
WIRED INPUT
EXPANDER OR
OR
OR
OROR
Support cascade connection
Note: A jumper is required on Termination_1 of the
last Speed-X device on the Speed-X bus.
Note: Add jumpers on all Termination_1 from the
second input module to the last input module.
a
b
©2022 Hangzhou Hikvision Digital Technology Co., Ltd. All rights reserved.
About this Manual
The Manual includes instructions for using and managing the Product. Pictures, charts, images and all other information hereinafter are for description
and explanation only. The information contained in the Manual is subject to change, without notice, due to firmware updates or other reasons. Please
find the latest version of this Manual at the Hikvision website (https://www.hikvision.com/).
Please use this Manual with the guidance and assistance of professionals trained in supporting the Product.
Trademarks
and other Hikvision’s trademarks and logos are the properties of Hikvision in various jurisdictions.
Other trademarks and logos mentioned are the properties of their respective owners.
Disclaimer
TO THE MAXIMUM EXTENT PERMITTED BY APPLICABLE LAW, THIS MANUAL AND THE PRODUCT DESCRIBED, WITH ITS HARDWARE, SOFTWARE AND
FIRMWARE, ARE PROVIDED “AS IS” AND “WITH ALL FAULTS AND ERRORS”. HIKVISION MAKES NO WARRANTIES, EXPRESS OR IMPLIED, INCLUDING
WITHOUT LIMITATION, MERCHANTABILITY, SATISFACTORY QUALITY, OR FITNESS FOR A PARTICULAR PURPOSE. THE USE OF THE PRODUCT BY YOU IS AT
YOUR OWN RISK. IN NO EVENT WILL HIKVISION BE LIABLE TO YOU FOR ANY SPECIAL, CONSEQUENTIAL, INCIDENTAL, OR INDIRECT DAMAGES, INCLUDING,
AMONG OTHERS, DAMAGES FOR LOSS OF BUSINESS PROFITS, BUSINESS INTERRUPTION, OR LOSS OF DATA, CORRUPTION OF SYSTEMS, OR LOSS OF
DOCUMENTATION, WHETHER BASED ON BREACH OF CONTRACT, TORT (INCLUDING NEGLIGENCE), PRODUCT LIABILITY, OR OTHERWISE, IN CONNECTION
WITH THE USE OF THE PRODUCT, EVEN IF HIKVISION HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES OR LOSS.
YOU ACKNOWLEDGE THAT THE NATURE OF THE INTERNET PROVIDES FOR INHERENT SECURITY RISKS, AND HIKVISION SHALL NOT TAKE ANY
RESPONSIBILITIES FOR ABNORMAL OPERATION, PRIVACY LEAKAGE OR OTHER DAMAGES RESULTING FROM CYBER-ATTACK, HACKER ATTACK, VIRUS
INFECTION, OR OTHER INTERNET SECURITY RISKS; HOWEVER, HIKVISION WILL PROVIDE TIMELY TECHNICAL SUPPORT IF REQUIRED.
YOU AGREE TO USE THIS PRODUCT IN COMPLIANCE WITH ALL APPLICABLE LAWS, AND YOU ARE SOLELY RESPONSIBLE FOR ENSURING THAT YOUR USE
CONFORMS TO THE APPLICABLE LAW. ESPECIALLY, YOU ARE RESPONSIBLE, FOR USING THIS PRODUCT IN A MANNER THAT DOES NOT INFRINGE ON THE
RIGHTS OF THIRD PARTIES, INCLUDING WITHOUT LIMITATION, RIGHTS OF PUBLICITY, INTELLECTUAL PROPERTY RIGHTS, OR DATA PROTECTION AND OTHER
PRIVACY RIGHTS. YOU SHALL NOT USE THIS PRODUCT FOR ANY PROHIBITED END-USES, INCLUDING THE DEVELOPMENT OR PRODUCTION OF WEAPONS OF
MASS DESTRUCTION, THE DEVELOPMENT OR PRODUCTION OF CHEMICAL OR BIOLOGICAL WEAPONS, ANY ACTIVITIES IN THE CONTEXT RELATED TO ANY
NUCLEAR EXPLOSIVE OR UNSAFE NUCLEAR FUEL-CYCLE, OR IN SUPPORT OF HUMAN RIGHTS ABUSES.
IN THE EVENT OF ANY CONFLICTS BETWEEN THIS MANUAL AND THE APPLICABLE LAW, THE LATTER PREVAILS.
This product and - if applicable - the supplied accessories too are marked with "CE" and comply therefore with the applicable harmonized
European standards listed under the EMC Directive 2014/30/EU, the RoHS Directive 2011/65/EU
2012/19/EU (WEEE directive): Products marked with this symbol cannot be disposed of as unsorted municipal waste in theEuropean Union. For
proper recycling, return this product to your local supplier upon the purchase of equivalent new equipment, or dispose of it at designated
collection points. For more information see: www.recyclethis.info
2006/66/EC (battery directive): This product contains a battery that cannot be disposed of as unsorted municipal waste in the European Union.
See the product documentation for specific battery information. The battery is marked with this symbol, which may include lettering to indicate
cadmium (Cd), lead (Pb), or mercury (Hg). For proper recycling, return the battery to your supplier or to a designated collection point. For more
information see:www.recyclethis.info
CAUTION
In the use of the product, you must be in strict compliance with the electrical safety regulations of the nation and region.
The socket-outlet shall be installed near the equipment and shall be easily accessible.
+ identifies the positive terminal(s) of equipment which is used with, or generates direct current. - identifies the negative terminal(s) of
equipment which is used with, or generates direct current.
No naked flame sources, such as lighted candles, should be placed on the equipment.
This equipment is suitable for mounting on concrete or other non-combustible surface only.
Install the equipment according to the instructions in this manual.
To prevent injury, this equipment must be securely attached to the wall in accordance with the installation instructions.
The additional force shall be equal to three times the weight of the equipment but not less than 50N. The equipment and its associated
mounting means shall remain secure during the installation.
After the installation, the equipment, including any associated mounting plate, shall not be damaged.


Produkt Specifikationer

Mærke: Hikvision
Kategori: Alarmsystem
Model: DS-PM1-I8O2-H

Har du brug for hjælp?

Hvis du har brug for hjælp til Hikvision DS-PM1-I8O2-H stil et spørgsmål nedenfor, og andre brugere vil svare dig




Alarmsystem Hikvision Manualer

Alarmsystem Manualer

Nyeste Alarmsystem Manualer