INSTRUCTION SHEET
http://www.idec.com
2012.3
B-1397
Confirm that the delivered product is what you have ordered. Read this
instruction sheet to make sure of correct operation. Make sure that the
instruction sheet is kept by the end user.
Laser Sensor
SA1E-L Series
2Type
SAFETY PRECAUTINS
In this operation instruction sheet, safety precautions are categorized
in order of importance to Caution.
Caution notices are used where inattention might cause personal
injury or damage to equipment.
1For safety use of a laser product
CAUTION
Caution - Use of controls or adjustments or performance of procedures
other than those specified in this manual may result in hazardous
radiation exposure.
This product emits a visible laser beam. Do not stare into the beam
directly. Furthermore, do not look the laser which is reflected at a
mirror-like object.
About safety standards of laser product, IEC60825-1 ”Safety of laser
products has been stipulated by the IEC(International Electortechnical
Commission). This product is classified as CLASS1 product
according to IEC60825-1.
This product complies with 21 CFR 1040.10 and 21 CFR 1040.11
according to Laser Notice No.50, dated June 24, 2007, issued by
CDRH(Center for Devices and Radiological Health) under FDA(Food
and Drug Administration).
Labels
Following “Warning label” and “Certification/Identification label” are affixed
on this product according to IEC 60825-1 and laser regulation of FDA.
When this product will be incorporated into final device system which is
exported to the USA, make sure that Certification/Identification label is
affixed.
CAUTION
blank : Cable (1m)
-2M : Cable (2m)
-5M : Cable (5m)
C : Connector (M8)
3 :
Light ON / Dark ON
selectable
SA1E-□□□□
Warning label Certification/Identification label
T : Through-beam
P : Polarized retro-reflective
B : Background suppression
N : NPN Output
P : PNP Output
3Installation
Do not apply excessive impact on the sensor during the installation
process, so as to prevent damage or deterioration in the degree of
protection.
To install the sensor, tighten the mounting screws to a torque of 0.5Nm or
less. (Fig.1)
Install the Background suppression type sensor head perpendicular to the
object transfer as shown below to minimize sensing errors. (Fig.2)
Mounting Bracket (Option)
SA9Z-K01
Mounting screws
M3 12×
Sensing Object
Correct Correct Incorrect
Sensing Object Sensing Object
(Fig.1) (Fig.2)
4Specifications
Detection System Through-beam Polarized retroreflective Background supression
TYPE No. NPN Output SA1E-LTN3 SA1E-LPN3 SA1E-LBN3
PNP Output SA1E-LTP3 SA1E-LPP3 SA1E-LBP3
Light Source Red Laser diode(Emission wavelength: 650nm)
IEC/JIS CLASS1
*1
Maximum output: 7mW
Power Voltage 12 to 24V DC Ripple p-p 10% maximum (Operationg range 10 to 30V DC)
Current Consumption Emitter : 15mA maximum 35mA maximum
Receiver : 30mA maximum
Sensing Range 30m 0.3 to 10 20 to 300mm
Reflector : IAC-R5/R8/R9
*2
(White paper 200×200mm)
Adjustable setting range - - 40 to 300mm
Hysterysis - - 10%
Minimum sensing object(typical) φ6mm opaque object (at 3m) φ6mm opaque object (at 3m) φ0.2mm copper wireat 170mm
Control Output Open collector output (NPN / PNP output selectable)
Load voltage : 30V DC maximum, Load current : 100mA maximum, Voltage drop : 1.5V maximum
Light-ON/Dark-ON switch selectable
Protection Circuit
Reverse polarity protection, Load short circuit protection
Reverse polarity protection, Load short circuit protection, Interference prevention
Response Time 250us maxium
Ambient Temperature
*3
Operating : -10 to +55 , Storage : -25 to +70 ℃ ℃ (no freezing and condensation)
Ambient Humidity Operating : 35 to 85% RH, Storage : 35 to 85% RH (no condensation)
Degree of protection IP67IEC60529
Material Housing: PBT Lens: PMMA, Display: PC
Cable φ3.5mm, 3-core(2-core for emitter of through-beam type), 0.2mm
2, 1m/2m/5m cabtyre cable
*1: This product complies with 21CFR 1040.10 and 1040.11 based on Notice No.50.
*2: Maintain at least the following distance between the sensor and reflector. IAC-R5/R8
/R9
: 300mm
*3: Maximum operating temperature is 50 when using this product as UL/c-UL listed products.
5Notes for Operation
6Wiring
Do not use the sensor during the transient time of 100 ms after turning
on the power supply.
If the sensor and the load are connected to different power supplies,
the sensor must always be turned on first.
Do not install the sensor outdoors, nearby induction device, or heat
source. Choose locations free from frequent vibrations, shocks, dust,
toxic gases, water, oil, and chemicals, so as to prevent malfunctions
and damage.
Do not expose the sensor to sunlight or other direct light projections.
Do not use the sensor with drops of water remaining on the lens or
aperture of slits.
In case installing the reflector of polarized retro-reflective type, make
fine adjustment of angle or position of the sensor or reflector.
This product emits high directional beam. Therefore the beam
possibly be out of alignment by the mounting condition. Make sure to
adjust the beam axes alignment before use.
Do not connect the sensor to AC power supply, so as to prevent
explosion and burning.
CAUTION
Turn off the power supply before wiring.
Connect correctly to prevent damage.
The power voltage must not exceed the rated range.
When using a switching power supply, be sure to ground the FG
(frame ground) terminal.
Do not install the sensor wiring in the same conduit with high-voltage
lines and power lines.
Cable extension is allowed up to 100m using a cabtyre cable with core
wires of 0.3 mm2 or more.
To connect the sensor with connector cable, tighten connector to a
torque of 0.5Nm or less.
Use a UL Listed (CYJV/CYJV7) mating connector/cord assembly
when using connector type as UL/c-UL listed products.
NPN Output Type
PNP Output Type
Through-beam Type (Emitter)
1
4
3
2
Connector pin
assignment
1
4
3
2
Connector pin
assignment
1
4
3
2
Connector pin
assignment
12 to
24V DC
Brown(1)
+V
0V
Blue(3)
Main circuit
WIRING DIAGRAM
12 to
24V DC
Load
Brown(1)
Black(4)
+V
OUT
0V
Blue(3)
Main circuit
12 to
24V DC
Load
Brown(1)
Black(4)
+V
OUT
0V
Blue(3)
Main circuit
Step
 1
 2
 
3
Distance Control Adjusting Procedure
Install a photoelectric sensor and the sensing
object. Turn the control counter-clockwise until
the operation LED turns OFF (*1). Then turn
clockwise until the operation LED turns ON
(point A).
Remove the sensing object, then the operation
LED turns OFF. Turn clockwise until the
operation LED turns ON (The background is
detected) (point B). (*2)
Set the middle point between point A and B as
point C. (*3)
7
Adjustment for Background suppression type
*1: If the operation LED turned off, turn on by turning the control
clockwise.
*2: Make one turn or more clockwise from point A and set the position as
point C when the background is too far and the operation LED dose
turn ON.
*3: There may be more than 1 turn between points A and B, since this
photoelectric sensor incorporates a 6-turn adjuster.
*4: Sensing range becomes longer when turned clockwise.
8Dimensions
CABLE TYPE
CONNECTOR TYPE
Note1: Stability Indicator and Sensitivity Control and Operation Mode
Switch are not attached to the Emitter of Through-Beam Type.
Note2: Power Indicator (Green LED) is attached to the Emitter of
Through-Beam Type instead of Operation Indicator.
7.8
Through-Beam
Sensitivity Control (except for BGS TYPE)(Note1)
Emitter axis
Sensing Range Control (for BGS Type)
Operation Indicator (Yellow LED)(Note2)
Operation Mode Switch (Note1)
Receiver axis(Receiver)
Stability Indicator (Green LED)(Note1)
Polarized Retro-Reflective
Background Suppression
Receiver axis
(Polarized Retro-Reflective)
Emitter axis(Emitter)
7.2
17.1
10.8
11.8
15.3
31.5
3.5
19.5
25.4
1.2
8.2
3.4
8.0
19.8
2-M3
3.2
31.5 1.2
4.5
6.3
19.5
25.4
3.4 M8X1
2-M3
17.1
7.2 8.0
19.8
7.8
Emitter axis
15.3
8.2
11.8
10.8 3.2
Sensitivity Control (except for BGS TYPE)(Note1)
Sensing Range Control (for BGS Type)
Operation Indicator (Yellow LED)(Note2)
Operation Mode Switch (Note1)
Stability Indicator (Green LED)(Note1)
Through-Beam
Receiver axis(Receiver)
Polarized Retro-Reflective
Background Suppression
Receiver axis
(Polarized Retro-Reflective)
Emitter axis(Emitter)
Sensing Range Control
6-turnendless
Operation Indicator (Yellow)
Operation Mode Switch
Stability Indicator (Green)
(*4)
A
B
A
B
C
A


Produkt Specifikationer

Mærke: Idec
Kategori: Ikke kategoriseret
Model: SA1E-LTP3-2M

Har du brug for hjælp?

Hvis du har brug for hjælp til Idec SA1E-LTP3-2M stil et spørgsmål nedenfor, og andre brugere vil svare dig




Ikke kategoriseret Idec Manualer

Ikke kategoriseret Manualer

Nyeste Ikke kategoriseret Manualer

Kramer

Kramer VP-8X8 Manual

25 November 2024
Kramer

Kramer PT-2C Manual

25 November 2024
Lazer

Lazer Bob+ Manual

25 November 2024
Dometic

Dometic DPS 80 Manual

25 November 2024
Kramer

Kramer 102MX Manual

25 November 2024
Kramer

Kramer FC-18 Manual

25 November 2024
Kramer

Kramer DSP-62-UC Manual

25 November 2024
Tiger

Tiger SKF-H101 Manual

25 November 2024