NEUTRAL
LOAD
L2
L2
LOAD
WHT
GRY
BLK
BLU
BRN
RED
YLW
BLOWER
PUMP
TIMER
OPTIONAL
FREEZE
240V SINGLE SPEED PUMP
240V BLOWER
240V FREEZE PROTECTION
L1
L2
BREAKER
IMPORTANT NEUTRAL WIRE MUST ALWAYS BE USED
NOTES:
1. Dot (•) indicates twist on wire connector.
2. If freeze protection is not required, permanently cap (twist on wire connector) brown lead.
This Air Switch is designed to control two separate
pieces of equipment with one air button. Without
electricity at the spa side, it can safely control a
pump and blower. Each press of the air button
will cycle between the sequences shown below.
When left in sequence one, the timer will operate
the pump at the times set for daily filtration. It also
has an input for freeze protection.
®INSTALLATION
OPERATION &
SERVICE MANUAL
FOUR FUNCTION AIR SWITCH WITH TIMER
Model: RC2343PT - Plastic Outdoor Enclosure Suitable for POOL/SPA Equipment Control
RATINGS: 20 A (R), 1 HP, 120 V, 60 Hz.; 20 A (R), 2 HP, 240 V, 60 Hz.
READ AND FOLLOW ALL INSTRUCTIONS IMPORTANT SAFTEY INSTRUCTIONS SAVE THESE INSTRUCTIONS
GENERAL INFORMATION
WIRING DIAGRAMS RC2343PT
L1
BREAKER
NEUTRAL
LOAD
N
N
LOW
HIGH
WHT
GRY
BLK
BLU
BRN
RED
YLW
BLOWER
PUMP
TIMER
OPTIONAL
FREEZE
120V TWO SPEED PUMP
120V BLOWER
120V FREEZE PROTECTION
L1
BREAKER
NEUTRAL
LOAD
L2
L2
LOAD
WHT
GRY
BLK
BLU
BRN
RED
YLW
BLOWER
PUMP
TIMER
OPTIONAL
FREEZE
240V SPEED PUMPSINGLE
240V BLOWER
240V FREEZE PROTECTION
L2
L1
L2
BREAKER
L1
BREAKER
NEUTRAL
LOAD
N
N
LOAD
WHT
GRY
BLK
BLU
BRN
RED
YLW
BLOWER
PUMP
TIMER
OPTIONAL
FREEZE
120V SINGLE SPEED PUMP
120V BLOWER
120V FREEZE PROTECTION
LIMITED WARRANTY
Warranty service is available by either (a) returning the product to the dealer from whom the unit was purchased or (b)
completing a warranty claim online at www.intermatic.com. This warranty is made by: Intermatic Incorporated, Customer
Service 1950 Innovation Way, Suite 300, Libertyville, IL 60048.
For warranty service go to: http://www.Intermatic.com or call 815-675-7000
Because of our commitment to continuing research and improvements, Intermatic Incorporated reserves the right to make changes,
without notice, in the specifications and material contained herein and shall not be responsible for any damages, direct or consequential,
caused by reliance on the material presented.
INTERMATIC INCORPORATED, LIBERTYVILLE, IL 60048
158--02178 4
RC2000 SERIES
AIR ACTUATED SPA CONTROLS
NEUTRAL
LOAD
L2
L2
LOW
HIGH
WHT
GRY
BLK
BLU
BRN
RED
YLW
BLOWER
PUMP
TIMER
OPTIONAL
FREEZE
240V TWO SPEED PUMP
240V BLOWER
240V FREEZE PROTECTION
L1
L2
BREAKER
BREAKER
L1
L1
BREAKER
NEUTRAL
LOAD
N
N
LOAD
WHT
GRY
BLK
BLU
BRN
RED
YLW
BLOWER
PUMP
TIMER
OPTIONAL
FREEZE
120V SINGLE SPEED PUMP
120V BLOWER
120V FREEZE PROTECTION
L1
BREAKER
NEUTRAL
LOAD
L2
L2
LOW
HIGH
WHT
GRY
BLK
BLU
BRN
RED
YLW
BLOWER
PUMP
TIMER
OPTIONAL
FREEZE
240V TWO SPEED PUMP
240V BLOWER
240V FREEZE PROTECTION
L2
L1
L2
BREAKER
BREAKER
L1
L1
BREAKER
NEUTRAL
LOAD
N
N
LOW
HIGH
WHT
GRY
BLK
BLU
BRN
RED
YLW
BLOWER
PUMP
TIMER
OPTIONAL
FREEZE
120V TWO SPEED PUMP
120V BLOWER
120V FREEZE PROTECTION
EQUIPMENT SEQUENCE
1 2 3 4
PUMP (SINGLE-SPEED) TIMER
ON/OFF ON ON OFF
PUMP (TWO-SPEED) TIMER
ON/OFF HIGH HIGH OFF
LOW
BLOWER OFF OFF ON ON
WARNING
Electrical connections to this equipment must be accomplished by a qualified electrician in accordance with the
National Electrical Code and in accordance with all local codes.
Disconnect power at the circuit breaker(s) or disconnect switch(es) before installing or servicing. More than one
circuit breaker or disconnect switch may be required to de-energize the equipment before servicing.
For outdoor locations or wet locations (rain-tight), conduit hubs that comply with requirements of the UL514B
(standard for fitting conduit and outlet boxes) are to be used.
Do NOT exceed maximum current carrying capacity.
Reinstall wire terminal cover after wiring is complete.
KEEP DOOR CLOSED AT ALL TIMES when not servicing.
The control panel is to be a minimum of 3 M. (in Canada) or 5 ft. (in USA) from the inside wall of the pool, spa, or
pond, unless separated from the body of water by a fence, wall or other permanent barrier that will make the unit
inaccessible to persons in the water.
For grounding and bonding of this Control and the installation, refer to section 680 of the National Electrical Code.
Risk of Fire or Electric Shock
1


Produkt Specifikationer

Mærke: Intermatic
Kategori: Fjernbetjening
Model: RC2343PT

Har du brug for hjælp?

Hvis du har brug for hjælp til Intermatic RC2343PT stil et spørgsmål nedenfor, og andre brugere vil svare dig




Fjernbetjening Intermatic Manualer

Fjernbetjening Manualer

Nyeste Fjernbetjening Manualer