Jablotron CA-322 Accent Manual
Læs nedenfor 📖 manual på dansk for Jablotron CA-322 Accent (2 sider) i kategorien Sikkerhed. Denne guide var nyttig for 9 personer og blev bedømt med 4.5 stjerner i gennemsnit af 2 brugere
Side 1/2
Immobilizer CA-322 „Accent“ 2 / 1 MDF532 05
Immobilizer CA-322 „Accent“ - instructions
The „Accent“ brand name system is suitable for all cars equipped with 12V voltage
and a negative ground. The CA-322 immobilizer is remotely controlled. RF
communication is protected by a FLOATING digital code and by an ANTI-SCAN
feature.
Arming and disarming of the system is confirmed by the turn indicators blinking.
While the ignition key is on, the system can not be armed. This protects the car from
having the system accidentally activated while driving. A visual warning of the presence
of the immobilizer is provided by an LED indicator.
Door lock outputs allow the central locking system to be controlled by the remote
control (programmable output pulse duration). A signal to close electrically powered
windows is also available.
An automatic Dome light control is provided by an extra door switch input/output
(negative trigger). It turns ON the dome light after disarming and the opening of any
door. The light will remain ON until you switch ON the ignition (max. 60 sec.).
A built in powerful immobilizer (3 relay contacts) can disable important systems
(starter, ignition, electrical fuel pump etc.).
The „Accent“ provides optional REARM and AUTOIMMO functions. REARM checks
if the car has been entered within one minute of disarming. If not, the immobilizer is
automatically rearmed and the doors are locked again. AUTOIMMO function will block
the car automatically if ignition key is turned off for more than 5 minutes. Optional
functions can be modified in setting mode by a professional mechanic after installation.
SPECIFICATIONS
voltage 10 - 16VDC
stand by consumption max. 20mA
working temperature -40 to +85°C
remote controller distance max. 20m
remote controller equipped with SAW resonator
coding digital floating code system with Anti-scan
turn indicator outputs 2 x +12V, max. 2 x 5A
central lock outputs pulses to GND, max. 300mA, 0.3 - 4sec.
optional „lock“ signal duration (for el. powered windows) 60sec.
immobilization relay contacts (3 loops) max. 15A permanently
max. 20A for 30 seconds
AUX output digital bus output (future use)
negative switched door contacts input / courtesy light output 10W
AL1 negative input / dome light output
VALET push button executive override, setting
All the data is stored to EEPROM memory.
This product complies with IEC 839-10-1, EEC No. 97
Hereby, Jablotron Ltd., declares that this CA-322 is in compliance with the essential
requirements and other relevant provisions of Directive 1999/5/EC. Original of the
conformity assessment can be found at the web page www.jablotron.cz, section
Technical support.
Note: Although this product does not contain any harmful materials we suggest you
to return the product to the dealer or directly to the producer after usage.
INSTALLATION
The immobilizer will work only if properly installed. Improper installation of the
system can result in poor and or dangerous car performance. We recommend
having the immobilizer professionally installed.
INSTALLATION INSTRUCTIONS: Disconnect the battery before starting
installation. Keep in mind that if your car has some memory functions, these
may be erased if you disconnect the battery. Nobody should be inside the car
equipped with airbags when connecting or disconnecting the battery. Refer to
the car owners' manual before disconnecting the battery.
Install the control unit in the passenger compartment. The recommended
location is under the dash board. The wire coming directly from the control unit is
the remote control antenna. The location of this wire will effect the remote control
working distance. Ideally, the wire should be near a window. If you drill a hole in
the car, be sure to check the area before drilling to prevent damage to the car.
LED indicator is on a separate cable. Once you have determined the
position on the dashboard where you want the LED light, drill a 6.5mm (4/16")
diameter hole in the dashboard and install the LED. Be sure to check for other
cables before you drill the hole. Connect the LED cable into any of the three
pin connectors on the main unit .
VALET Switch - has a separate cable. This push button switch can be used
as an executive override if the remote control is lost. However, if the VALET
switch was optionally disabled in setting mode, it will not be able to override.
Find a hidden place in the car and install the switch. Connect the cable to any
of the three pin connectors on the main unit.
WIRING - route wires for the immobilizer with the electrical harness of the car.
Check each connection made to ensure that it is solid and properly insulated.
Use only a real crimping tool to make connections. Complete and check all wiring
before switching on the power. Each wire is marked by a number on its end
(remove the numbers after installation).
1 = Positive Supply - connect this wire to a direct line from the positive
terminal of the battery. This wire is split in the immobilizer wire harness. The
loop with the fuse (10Amp), is a separate power supply for turn lights. The
fuse protects against a short connection of the turn indicator bulb. Use only
a 10A fuse in this harness!
2 = Grounding - connect this wire to the original GND point in the car.
4 = „Lock“, 5 = „Unlock“ - these wires provide signals to control the central
door lock system. The maximum output current for either of these lines is
300mA. NPN transistors switching to the GND are on the output of these lines.
The duration of output pulses is programmable (0.3sec. factory default).
Connect the wires from the „Accent“ to the inputs of the central locking system
control unit.
If the car has powered windows with a “close all windows” button you can
use the „Lock“ signal to close all the windows. In this case, select the longer
“Locking Signal“ in the setting mode This way the immobilizer will lock the
doors and will close all windows if button A (1) is used for arming and it will
only lock the doors if button B (2) is used.
Do NOT connect the wires from the immobilizer directly to the actuators! See
"Examples of Accent use for different central locking systems" if your locking
system uses another type of control signals. If you are also going to install
a central locking system in your car, we recommend the CL-20A.
6 = Ignition Key Input - connect this wire to the ignition key switch (+12V
when ignition is ON). This signal will prevent accidental arming of the system
while driving. This signal is also used for REARM and AUTOIMMO functions.
Note: Be sure, that +12V is also present, when a starter is used.
7 = Door Switches input, Dome Light Control output - is a negative trigger
input for REARM function. It also functions as the dome light control output.
Connect this wire to the door switches (we recommend to have switches installed
in all doors). With the system is disarmed, opening the door turns on the interior
dome light till the ignition key is switched on (max. 1 minute).
Note: The maximum load of the interior light can be 10W.
8 = AL1 Negative Input for REARM function and dome light controlling. It
can be used for trunk switch.
13 and 14 = Turn Indicators - the two wires provide power for the left and
right turn indicators. Each wire provides 12V, 5A pulses to the lights as
a visual indication of arming and disarming. Connect one of the wires to the
left turn light and the other wire to the right turn light.
Immobilization - the six wires in a separate connector are the three built-in
immobilization contacts’ leads. The following wires are connected by internal
relay contacts inside: 1-3, 2-4, 5-6. The starter, fuel pump, ignition or any other
system that when electrically disconnected will render your car inoperative, may
be connected here. Only disarming the system and switching ON the key in the
ignition closes the contacts. These contacts will operate correctly for permanent
load up to 15A, max. 20A for 30 seconds (each).
Adding of a new remote controller
There are two remote controllers in each „Accent“ immobilizer set. The system
can be operated with a maximum of three remote controllers. To add an
additional remote control or to replace an original one (in the case one is lost)
perform the following procedure:
Switch on the ignition key when immobilizer is disarmed and press the hidden
VALET button five times (in 1 minute from the moment when you turned on the
ignition). The turn indicators will make two long signals and the LED will light
continuously. The control unit is now in remote control learning mode.
You must activate all remote controls (one by one, button A, B, 1 or 2) which you
want accepted by the immobilizer. The control unit will store codes in its memory
(confirmed by a LED flash and for a brand new code also by a turn lights signal).
Keep in mind that only three controllers can be taught to the immobilizer. If
you try to teach a fourth controller, the first one will be forgotten and so on. If
you activate only one controller in learning mode, you will be able to control
the system only with this one controller.
To close learning mode, switch off the ignition key. You can see how many
remote controls are available for your immobilizer by number of LED flashes every
time when you switch on the ignition key.
Setting mode
Optional functions can be modified. To enter the setting mode perform the
following procedure:
• press the hidden VALET button switch when the immobilizer is disarmed
and hold it pressed
• after 5 seconds (or more) switch on the ignition key
• the turn lights will make one long and one short signal and the LED will light
continuously
• release the VALET button; the immobilizer is now in setting mode
Now you can make setting; see the following table (you are in row no. 1).
Setting of the parameter is indicated by LED and can be changed by a remote
control button (A or B), each short pressing will change the parameter (on - off
- on - off - etc.). Bold printed parameters are factory default settings.
To select next parameter (next row in the table), press VALET button quickly.
The turn lights will confirm parameter (row) number by the number of signals.
Step by step go through all parameters. When you are on parameter number
5 the next VALET button pressing will store all the programming to the memory
and the setting mode will be exited (confirmed by the turn lights with one long
signal). If you switch the ignition key off any time before the setting mode is
completed, the setting mode will be terminated and no changes will be stored.
Note: All data is stored to EEPROM memory, so removing power from the
immobilizer will not change them.
no. parameter R (on) status (LED) l (off) description
1 REARM enabled disabled if car is not entered within 1 min. after disarming, it will arm again
2 AUTOIMMO enabled disabled if enabled it will block engine if ignition key is switched off for more than 5 min.
3 duration of locking pulses 0,3 sec. 4 sec. modify „lock“ and „unlock“ output pulse duration
4 longer „lock“ signal 60 sec. normal the „lock“ pulse is normal (see step no. 3) or longer (60 seconds)
5
emergency disarm with VALET
enabled
disabled if emergency disarm is disabled, VALET button can only be used for setting (emergency
disarm is possible only by a professional mechanic)
Produkt Specifikationer
Mærke: | Jablotron |
Kategori: | Sikkerhed |
Model: | CA-322 Accent |
Har du brug for hjælp?
Hvis du har brug for hjælp til Jablotron CA-322 Accent stil et spørgsmål nedenfor, og andre brugere vil svare dig
Sikkerhed Jablotron Manualer
22 August 2024
22 August 2024
21 August 2024
21 August 2024
21 August 2024
21 August 2024
21 August 2024
19 August 2024
17 August 2024
17 August 2024
Sikkerhed Manualer
- Sikkerhed Bosch
- Sikkerhed EasyMaxx
- Sikkerhed Fenton
- Sikkerhed Siemens
- Sikkerhed Panasonic
- Sikkerhed Doro
- Sikkerhed Technaxx
- Sikkerhed Waeco
- Sikkerhed Grundig
- Sikkerhed Nedis
- Sikkerhed Friedland
- Sikkerhed Abus
- Sikkerhed Theben
- Sikkerhed TRENDnet
- Sikkerhed Optex
- Sikkerhed Smartwares
- Sikkerhed Trust
- Sikkerhed Fysic
- Sikkerhed Blaupunkt
- Sikkerhed Honeywell
- Sikkerhed Bavaria
- Sikkerhed Medion
- Sikkerhed EZVIZ
- Sikkerhed Elro
- Sikkerhed Steinel
- Sikkerhed Geemarc
- Sikkerhed Unitron
- Sikkerhed Topcraft
- Sikkerhed Powerfix
- Sikkerhed Netgear
- Sikkerhed Maginon
- Sikkerhed Yale
- Sikkerhed Nest
- Sikkerhed Jacob Jensen
- Sikkerhed Goobay
- Sikkerhed Alecto
- Sikkerhed Juwel
- Sikkerhed Dymond
- Sikkerhed AXA
- Sikkerhed B/R/K
- Sikkerhed Marmitek
- Sikkerhed Basetech
- Sikkerhed Foscam
- Sikkerhed Velleman
- Sikkerhed LevelOne
- Sikkerhed Perel
- Sikkerhed JUNG
- Sikkerhed Netatmo
- Sikkerhed Eden
- Sikkerhed Eufy
- Sikkerhed Lamax
- Sikkerhed Overmax
- Sikkerhed Somfy
- Sikkerhed Y-cam
- Sikkerhed Hikvision
- Sikkerhed Monacor
- Sikkerhed Brennenstuhl
- Sikkerhed Devolo
- Sikkerhed Grandstream
- Sikkerhed Trebs
- Sikkerhed Switel
- Sikkerhed Easy Home
- Sikkerhed Orbis
- Sikkerhed Eminent
- Sikkerhed Grothe
- Sikkerhed Kopp
- Sikkerhed Provision-ISR
- Sikkerhed Audiovox
- Sikkerhed Axis
- Sikkerhed Goliath
- Sikkerhed Plustek
- Sikkerhed First Alert
- Sikkerhed Prestigio
- Sikkerhed V-TAC
- Sikkerhed Profile
- Sikkerhed Ajax
- Sikkerhed Alphatronics
- Sikkerhed AngelEye
- Sikkerhed Aritech
- Sikkerhed AceSee
- Sikkerhed Airbolt
- Sikkerhed Alhua - Dahua
- Sikkerhed Tevion
- Sikkerhed Marquant
- Sikkerhed Ednet
- Sikkerhed ME
- Sikkerhed Bticino
- Sikkerhed Sygonix
- Sikkerhed Nemef
- Sikkerhed Dahua
- Sikkerhed Hagenuk
- Sikkerhed Logicom
- Sikkerhed Xavax
- Sikkerhed Elkron
- Sikkerhed Niko
- Sikkerhed Gira
- Sikkerhed Interlogix
- Sikkerhed Dnt
- Sikkerhed Fito
- Sikkerhed Urmet
- Sikkerhed Iget
- Sikkerhed Wanscam
- Sikkerhed Satel
- Sikkerhed Notifier
- Sikkerhed Golmar
- Sikkerhed Batavia
- Sikkerhed Storage Options
- Sikkerhed NetworX
- Sikkerhed Bitron Video
- Sikkerhed Zmodo
- Sikkerhed Elro-Flamingo
- Sikkerhed Electronics Line
- Sikkerhed One2track
- Sikkerhed HUMANTECHNIK
- Sikkerhed PIR Alarm
- Sikkerhed Heidemann
- Sikkerhed Directed Electronics
- Sikkerhed Oplink
- Sikkerhed BML
- Sikkerhed Unitec
- Sikkerhed Muller
- Sikkerhed Home8
- Sikkerhed AVTech - Velleman
- Sikkerhed Galaxy
- Sikkerhed Sonic Alert
- Sikkerhed I-onik
- Sikkerhed Smartalarm
- Sikkerhed GE Security
- Sikkerhed Microtech
- Sikkerhed Nor-tec
- Sikkerhed Entrya
- Sikkerhed Tegui
- Sikkerhed Stobo
- Sikkerhed Kompernass
- Sikkerhed Iiquu
- Sikkerhed Storex
- Sikkerhed Powermax
- Sikkerhed Woonveilig
- Sikkerhed Mikros
- Sikkerhed Bolyguard
- Sikkerhed Indexa
- Sikkerhed Skytronic
- Sikkerhed Paradox
- Sikkerhed Flamingo FA15RF
- Sikkerhed SecuFirst
- Sikkerhed BRK DICON
- Sikkerhed FBII
- Sikkerhed FlinQ
- Sikkerhed Dericam
- Sikkerhed Myfox
- Sikkerhed Kocom
- Sikkerhed RISCO Group
- Sikkerhed SmartHome
- Sikkerhed Bellman
- Sikkerhed Protector
- Sikkerhed I-Tel
- Sikkerhed Home Protector
- Sikkerhed Ksenia
- Sikkerhed Mr Safe
- Sikkerhed Epine
- Sikkerhed Inner Range
- Sikkerhed Dedicated Micros
- Sikkerhed Visonic
- Sikkerhed PROmax
- Sikkerhed Selvag
- Sikkerhed Voxx
- Sikkerhed Fracarro
- Sikkerhed Guardall
- Sikkerhed Xena
- Sikkerhed Smanos
- Sikkerhed One Concept
- Sikkerhed QuattSecure
- Sikkerhed NetBotz
- Sikkerhed Securitas
Nyeste Sikkerhed Manualer
5 Oktober 2024
23 September 2024
23 September 2024
23 September 2024
21 September 2024
20 September 2024
19 September 2024
19 September 2024
17 September 2024
17 September 2024