Side 1/3
ENGLISH
CLEANING
Be sure the tester is disconnected from both the input and output port. Use clean, dry, soft
lint-free cloth to wipe down the entire unit.
•
Do NOT use abrasive cleaners or solvents.
STORAGE
Do not expose to high temperatures or humidity. After a period of storage in extreme conditions
exceeding the limits mentioned in the General Specifications section, allow the tester to return to
normal operating conditions before using.
DISPOSAL / RECYCLE
Do not place equipment and its accessories in the trash. Items must be properly disposed
of in accordance with local regulations. Please see www.epa.gov www.erecycle.org or for
additional information.
CUSTOMER SERVICE
KLEIN TOOLS, INC.
450 Bond Street, Lincolnshire, IL 60069 1-877-553-4676
customerservice@kleintools.com www.kleintools.com
SYMBOLS ON TESTER
Important information: It is
important that users of this
tester read, understand, and
follow all warnings, cautions,
safety information, and
instructions in this manual
before operating this tester.
Failure to follow instructions
could result in death or serious
injury.
Warning – Risk of electric shock
This product has been independently tested by
Intertek and meets applicable published standards
Conformité Européenne: Conforms with European
Economic Area directives
Read instructions before using
USB
NOTE: No user-serviceable parts inside.
FIG. 1 FIG. 2
ET910
INSTRUCTION MANUAL - USB DIGITAL METER & TESTER - TYPE A
54
3
7 1
6
2
Default Screen
Vol: ##.## V
Cur: #.## A XXXX
###### mAh ####Wh
Tme: ###:##:##
F
A
D
B
CG
Memory Screen
Vol: ##.## V M:#
Cur: #.## A
###### mAh ####Wh
Tme: ###:##:##
A
D
B
CG I
1.
Power source INPUT (USB-A)
2. Load OUTPUT (USB-A)
3. Current Test Load button
4. Mode button
5. Current Test Load
LED Indicator
6. LCD display
7. Ventilation slots
(front & back)
A. DC voltage
B. DC current
C. Capacity/Charge delivered (mAh)
D. Elapsed Time (Hour:Min:Sec)
E. Memory cleared indicator
F. PASS/FAIL indicator
G. Energy delivered (Wh)
H. Resistance (Ω)
I. Memory Location ( , , etc)M:1 M:2
Enhanced Screen
##.## V CLR
#.## A XXXX
###### mAh ####Wh
###:##:## ###.#Ω
E
A
D
B
C HG F
FUNCTION BUTTONS (FIG. 1)
MODE BUTTON
4
(Screen Toggle/Data Storage/Memory reset)
The Mode button serves three purposes:
1. Switch between screens (FIG. 2):
• From the default screen, pressing and releasing once will switch to the
Enhanced Screen.
• From the default screen, pressing and releasing twice will switch to the
Memory Screen.
• When in the Memory Screen, repeated pressing will cycle through all 10
memory locations, beginning with M:1.
2. Data/Memory Storage and Recall:
• To record a reading during live monitoring event, press and hold the Mode
button for 3 seconds. Release the button after the memory location (i.e.
M:1) flashes momentarily on the screen. The next set of readings will
be stored at the next available location until all 10 memory locations are
used.
NOTE: After all 10 locations are used, subsequent readings will
overwrite the original 10 stored readings, beginning with M:1.
3. Memory Reset:
• To reset or erase all data in memory, press and hold the Mode button for 5
seconds from the Memory screen until the letters flash in the upper right CLR
corner (Fig. 2). All data in memory will be erased in all 10 memory locations.
GENERAL SPECIFICATIONS
The Klein Tools ET910 is a USB digital multi-meter and tester combination for USB
Type-A ports only. It simultaneously measures and displays the USB port voltage,
current, capacity, energy, and resistance. It can also test the maximum current delivery
capability of the USB port with internally built-in fixed loads-so user need not connect
to an external load. It will function with any USB Type-A port that has the ability to
deliver power. It requires NO batteries and uses minimal power from the power source
to function, ensuring accurate and reliable readings.
• Measurement Range:
Voltage: Current: 3 to 20V DC 0.05 to 3A
Capacity used: Energy delivered: 99,999mAh MAX* 999Wh MAX*
Resistance: 400Ω MAX
Elapsed Time:
Up to 999 hours, 59 min, 59 sec*
*
Based on display layout
• Operating and Storage Altitude: Up to 6562 ft. (2000 m)
• Operating and Storage Temp: ° ° ° °14 to 122 F (-10 to 50 C)
• Relative Humidity: <95% non-condensing
• Dimensions: Tester: 4.31" x 2.15" x 0.98" (110 x 54 x 25 mm)
Cable: Approx. 4" (100 mm)
• Weight: Pollution degree: 2.8 oz. (78 g) 2
• Drop Protection: Ingress Protection: 6.6 ft. (2 m) IP20
• Compatibility: Qualcomm Quick Charge® Compatible
• Standards:
EN 61326-1, EN61326-2-2, FCC Part 15B VOC.
Conforms to UL STD. 61010-1, 61010-2-030.
Certified to CSA STD. C22.2 No. 61010-1, 61010-2-030.
Specifications subject to change.
FUNCTION BUTTONS (FIG. 1)
TEST LOAD BUTTON
3
(Selects current load to output)
Available test load values are 0.5A, 1.0A, 2.0A, and 3.0A. Quick presses of the Test Load
button will toggle through the values. Default testing load at power-on is 0.5A; to select
1.0 A press once, for 2.0A press twice, and for 3.0A press three times.
The selected load value is indicated by the red LEDs beneath the display. Testing will
initiate at the indicated load after about three seconds of releasing the Test Load button, so
it is important to select the desired load quickly. If no load is selected within one second
after powering on, testing will initiate at 0.5A.
NOTE: The output USB
2
is disabled when the test load is used.
WARNINGS
T
o ensure safe operation and service of the tester, follow these instructions. Failure to
observe these warnings can result in severe injury or death.
• NOTThis tester will display current below 50 mA, even if it is allowing this to pass
through.
NOTE: The display will show zero current.
• DO NOT use with ports that operate outside of the rated voltage and current.
• Before each use verify tester operation by measuring a known voltage or current.
• NEVER use on a circuit with voltage or current that exceeds the maximums specified
for this device. (Display will read "OVERLOAD" in this condition)
• DO NOT use during electrical storms or in wet weather.
• DO NOT use if tester appears to be damaged.
• Use caution when working with voltages above 25V AC RMS or 60V DC. Such voltages
pose a shock hazard.
NOTE: Voltage above 24V DC will damage product.
• Always adhere to local and national safety codes. Use personal protective equipment
to prevent shock and arc blast injury where hazardous live conductors are exposed.
CAUTION
• DO NOT attempt to repair this tester. there are no serviceable parts.
• DO NOT modify this tester in any way.
• DO NOT expose to extremes in temperature or high humidity.
• NOTThis tester will be able to monitor a source port if any of the following conditions
occur:
• The USB port or plug is not properly connected.
• The source device shuts down. Some portable storage batteries have auto-
shutdown or standby modes to save power if no load is detected from
downstream device.
OPERATING INSTRUCTIONS
MONITORING MODE
NOTE: The input plug must be connected to a powered USB device before the downstream
device is connected to the output port. "Downstream device" refers to any device that has
the ability to draw current over USB.
1. Connect the input connector to the USB port to be monitored
• The display will turn on with Klein Tools logo screen and move quickly to the Default Screen (FIG 2).
• If the source port has power, it should only display a live voltage reading within the operating
range, 3-20V DC.
NOTE: Most USB ports deliver ~5V DC.
2. Connect the device being charged at output port. The display will show actual readings (FIG. 2).
3. User can monitor in either default or enhanced screens. Information displayed will differ (FIG. 2).
TESTING MODE
NOTE: Disconnect external load to operate in this mode.
The ET910 USB digital multi-meter can be used to test the maximum current that may be delivered
from a powered USB port.
1. Connect the input connector to the USB port to be monitored.
• The display will turn on with Klein Tools logo screen and move quickly to the Default Screen (FIG 2).
• If the source port has power, it should only display a live voltage reading within the operating
range, 3 – 20V DC.
NOTE: Most USB ports deliver ~5V DC.
2. Press the Test Load button to select test load.
3. Testing loads under 10V will take 3 seconds; loads over 10V will take 1 second. The red LED
remains lit during testing. Once complete, the results will be displayed, including "PASS" or
"FAIL". "PASS" indicates that the USB port delivered up to the load current being tested. LED
shuts off after testing is complete.
NOTE: Some USB power sources have integrated self-protection circuitry which the tester may
trigger, shutting off the source output, resulting in the tester also shutting off, failing the test.
NOTE: If the tester heats up beyond operating temperature following multiple current measurements,
test mode will automatically deactivate and will show on the display. If this occurs, disconnect "HOT"
all external input and output devices until the tester returns to normal operating temperature.
4. To save the test data, see in the section.Data/Memory Storage and Recall FUNCTION BUTTONS
5. To move on to the next test, press and release the Test Load or Mode button. The "PASS" or "FAIL"
indicator will disappear. The tester is now ready for the next test. To switch to Monitoring mode,
see MONITORING MODE section.
NOTE: "mAh" resets only when source is disconnected.
Produkt Specifikationer
Mærke: | Klein Tools |
Kategori: | Multimeter |
Model: | ET910 |
Har du brug for hjælp?
Hvis du har brug for hjælp til Klein Tools ET910 stil et spørgsmål nedenfor, og andre brugere vil svare dig
Multimeter Klein Tools Manualer
28 December 2024
28 December 2024
27 August 2024
27 August 2024
19 August 2024
25 Maj 2024
Multimeter Manualer
- Multimeter Bosch
- Multimeter Hager
- Multimeter Owon
- Multimeter Extech
- Multimeter Silverline
- Multimeter Emos
- Multimeter Metrix
- Multimeter TFA
- Multimeter Pyle
- Multimeter Biltema
- Multimeter Abus
- Multimeter Keithley
- Multimeter Hama
- Multimeter Milwaukee
- Multimeter BENNING
- Multimeter Clas Ohlson
- Multimeter Metrel
- Multimeter Kyoritsu
- Multimeter Laserliner
- Multimeter Parkside
- Multimeter FERM
- Multimeter Stanley
- Multimeter Elro
- Multimeter REV
- Multimeter Elworks
- Multimeter Powerfix
- Multimeter Digitus
- Multimeter Alecto
- Multimeter Schneider
- Multimeter Basetech
- Multimeter Voltcraft
- Multimeter Testboy
- Multimeter Greenlee
- Multimeter Velleman
- Multimeter Somogyi
- Multimeter FLIR
- Multimeter Perel
- Multimeter JUNG
- Multimeter APPA
- Multimeter Amprobe
- Multimeter Fluke
- Multimeter Monacor
- Multimeter Brennenstuhl
- Multimeter Projecta
- Multimeter Maxwell
- Multimeter Testo
- Multimeter GW Instek
- Multimeter Brandson
- Multimeter Ideal
- Multimeter Multimetrix
- Multimeter Mastech
- Multimeter Högert
- Multimeter Brüder Mannesmann
- Multimeter Vimar
- Multimeter PeakTech
- Multimeter Rigol
- Multimeter Uni-T
- Multimeter Joy-It
- Multimeter Wiha
- Multimeter HT Instruments
- Multimeter Chauvin Arnoux
- Multimeter Megger
- Multimeter Qian
- Multimeter Aim TTi
- Multimeter Steren
- Multimeter Gossen Metrawatt
- Multimeter Yato
- Multimeter Beha-Amprobe
- Multimeter Bearware
- Multimeter Sonel
- Multimeter Profile
- Multimeter Aldi
- Multimeter Amiko
- Multimeter Workzone
- Multimeter Tacklife
- Multimeter Etekcity
- Multimeter Digi-tool
- Multimeter Skandia
- Multimeter Elma
- Multimeter Hubinont
- Multimeter Kewtech
- Multimeter Strex
- Multimeter MBS
- Multimeter MGL Avionics
- Multimeter PCE Instruments
- Multimeter Micronta
- Multimeter CEM
- Multimeter Horex
- Multimeter Cosinus
- Multimeter Testec
- Multimeter Kurth Electronic
- Multimeter IWH
- Multimeter Weltron
- Multimeter Sanwa
- Multimeter Rohde & Schwarz
- Multimeter EEVBlog
- Multimeter Kingcraft
- Multimeter Weidmüller
- Multimeter Caltek
- Multimeter Noyafa
Nyeste Multimeter Manualer
2 Januar 2025
31 December 2025
28 December 2024
28 December 2024
27 December 2024
22 December 2024
21 December 2024
18 December 2024
16 December 2024
15 December 2024