6
4
5
1
2
7
9
8
10
3
Importado por: KLEIN TOOLS DE MEXICO
S. DE R.L. DE C.V. AV. Benito Juarez Garcia
No. 75, 77 y 79 No. Int. 9
Col. San Mateo Cuautepec
Tultitlán Estado de México. C.P. 54948
RFC KTM-710310-645
Contenido: 1 pieza
WARNINGS
To ensure safe operation and service of the tester, follow these
instructions. Failure to observe these warnings can result in severe
injury or death.
LASER RADIATION, Class IIIa laser. direct laser beam into eyes, DO NOT DO NOT
stare into the beam, or view directly with optical instruments as this can cause DO NOT
severe and permanent eye damage.
Risk of electric shock and burn. Contact with live circuits could result in death or
serious injury.
Use caution with voltages above 25V AC as a shock hazard may exist.
A blinking LED or a steadily illuminated LED in the tip and audible beeps indicate
presence of voltage. If no indication, voltage could still be present.
Before and after each use, verify operation by testing a known working circuit that is
within the rating of this unit.
Never assume neutral or ground wires are de-energized. Neutrals in multi-wire branch
circuits may be energized when disconnected and must be retested before handling.
The tester detect voltage if:WILL NOT
The wire is shielded.
The operator is not grounded or is otherwise isolated from an effective earth ground.
The voltage is DC.
The tester MAY NOT detect voltage if:
The user is not holding the tester.
The user is insulated from the tester with a glove or other materials.
The wire is partially buried or in a grounded metal conduit.
The tester is at a distance from the voltage source.
The field created by the voltage source is being blocked, dampened, or otherwise
interfered with.
The frequency of the voltage is not a perfect sine wave between 50 and 500Hz.
The tester is outside of operating conditions (listed in Specifications section).
Operation may be affected by differences in socket design and insulation thickness
and type.
In bright light conditions, the LED visual indicators will be less visible.
When powered-ON, one of the “power-ON” LEDs will be illuminated.
DO NOT USE
TESTER UNLESS ONE OF THEPOWER-ON” LED IS ILLUMINATED.s
Do not use if tester appears damaged or is not operating properly. If in doubt, replace
the tester.
Do not apply more than the rated voltage as marked on the tester (1000V).
Detection above 70V AC in Mode 1, or above 12V AC in Mode 2 is specified under
"normal" conditions as detailed below. The tester may detect at a different threshold at
different conditions, or may not detect at all unless:
The tip of the tester is within 0.25" (6 mm) of an AC voltage source radiating unimpeded.
The user is holding the body of the tester with his or her bare hand.
The user is standing on or connected to earth ground.
The air humidity is nominal (50% relative humidity non-condensing).
The tester is held still.
Always wear approved eye protection.
Comply with local and national safety requirements.
If this product is used in a manner not specified by the manufacturer, protection
provided by the product may be affected.
ENGLISH
OPERATING INSTRUCTIONS
SELECTING VOLTAGE TESTING MODE
NCVT5 can detect voltage in two distinct modes, defined by the
voltage ranges to which the tester is sensitive. Mode 1 detects 70 to
1000V AC, Mode 2 detects 12 to 1000V AC.
With the tester powered-
ON, successive presses of the NCV Power-ON button
1
will switch
the tester between modes 1 and 2. The Power-ON indicator LEDs
3
will indicate the currently active mode.
The tester will power-ON in the
mode that was most recently used.
OPERATING INSTRUCTIONS
CHECKING FOR THE PRESENCE OF AC VOLTAGE
1. Prior to use, test on a known live circuit to verify tester
functionality.
2. Place tip of the tester
5
near AC voltage. If voltage is present,
the unit will emit audible beeps and the LEDs in the tip
4
will
illuminate:
Mode Power-On
LED Color 12 to 70V AC >70 to 1000V AC
Mode 1
70 – 1000V
Range
Red
No illumination, no
sound Red LED in tip
4
illuminated, continuous
audible beep
Mode 2
12 – 1000V
Range
Blue
Blue LED in tip
4
blinking, pulsing
audible beep
Red LED in tip
4
illuminated, continuous
audible beep
NOTE: In Mode 2, the tester is more sensitive to high voltage sources
and electrically noisy environments. It is recommended to set the
tester to operate in Mode 1 when expected voltages are above 70V AC.
SILENT OPERATION
To activate silent operation, power-ON by pressing and holding the
NCV Power-ON button
1
for more than 2 seconds. Power-ON in this
manner each time silent operation is desired.
CLEANING
Be sure tester is turned off and wipe with a clean, dry lint-free
cloth.
Do not use abrasive cleaners or solvents.
STORAGE
Remove the batteries when not in use for a prolonged period
of time. Do not expose to high temperatures or humidity. After
a period of storage in extreme conditions exceeding the limits
mentioned in the General Specifications section, allow the tester to
return to normal operating conditions before using.
DISPOSAL / RECYCLE
Do not place equipment and its accessories in the trash.
Items must be properly disposed of in accordance with local
regulations. Please see www.epa.gov www.erecycle.org or
for additional information.
CUSTOMER SERVICE
KLEIN TOOLS, INC.
450 Bond Street, Lincolnshire, IL 60069
1-877-553-4676
customerservice@kleintools.com
www.kleintools.com
MAINTENANCE
BATTERY REPLACEMENT
If activating the laser pointer results in a blinking red LED
3
,
the battery
level is too low to operate the laser, but the NCVT may still be used. If
attempts to use either the NCVT or the Laser Pointer results in a blinking
blue LED
3
, the batteries must be replaced.
1. Unscrew the battery cap
9
and remove/recycle spent batteries.
2. Install two new AAA batteries. Note proper polarity.
3. Screw battery cap tightly to ensure a tight seal with the O-Ring
8
.
FUNCTION BUTTONS (FIG. 1)
NCV POWER ON/OFF BUTTON
1
To activate the Non-Contact Voltage Testing feature, press and
release the NCV Power-ON button
1
. The tester will emit a
single beep and one of the Power ON LEDs
3
will illuminate
3
indicating which NCVT mode is active (see OPERATING
INSTRUCTIONS). To power-OFF the tester, press and hold the
NCV button.
NOTE: The tester will automatically power-OFF following 4 minutes
of inactivity to conserve battery life.
LASER ON/OFF BUTTON
2
Press and hold the Laser Power Button
2
to activate the laser
pointer. Release the button to deactivate the laser.
WARNING: LASER RADIATION. do any of the DO NOT
following, as severe and permanent eye damage could result:
DO NOT direct laser beam into eyes.
DO NOT stare into the beam.
DO NOT view directly with optical instruments.
CAUTION
DO NOT attempt to repair this tester. It contains no serviceable parts.
DO NOT expose tester to extremes in temperature or high humidity.
ENGLISH
1.NCV Power On/Off Button
2.Laser Power On/Off Button
3.Power On/Mode LEDs
4.Voltage Detection LEDs (Inside Tip)
5.Non-Contact Tip
6.Laser Aperture
7.Pocket Clip
8.O-ring Seal
9.Battery Cap
10. 2x AAA Batteries (Included)
NOTE: There are no
user-serviceable parts
inside tester.
1.
Botón de encendido y apagado "NCV"
2.Botón de encendido y
apagado del láser
3.LED de encendido/modo
4.LED de detección de voltaje
(en el interior de la punta)
5.Punta para detección y
medición sin contacto
6.Apertura del láser
7.Clip de bolsillo
8.Junta tórica
9.Tapa del compartimento de baterías
10. 2baterías AAA (incluidas)
ESPAÑOL
NOTA: El probador no contiene
en su interior piezas que el
usuario pueda reparar.
1.Bouton marche/arrêt NCV
(test de tension sans contact)
2.Bouton marche/arrêt du
pointeur laser
3.VoyantsDEL de marche/mode
4.VoyantsDEL de détection de tension
(dans la pointe)
5.Pointe sans contact
6.Ouverture du laser
7.Agrafe pour poche
8.Joint torique
9.Couvercle de piles
10. 2pilesAAA (comprises)
FRANÇAIS
REMARQUE: Ce testeur
ne contient aucune pièce
réparable par l’utilisateur.
Made in China
Hecho en China
Fabriqué en Chine
1330540 Rev 06/18 D
KLEIN TOOLS, INC
Chicago, IL USA
© 2018
Detects AC voltage from 12 to 1000V with visual & audible indicators.
Two detection ranges: 70 to 1000V and 12 to 1000V.
Bright integrated laser pointer.
• Detecta voltaje CA de 12V a 1000V mediante indicadores
visuales y audibles.
Dos rangos de detección: 70V a 1000V y 12V a 1000V.
Puntero láser integrado, con haz de luz brillante.
• Détecte la présence d’une tension allant de 12 à 1000Vc.a. et la
signale au moyen d’indicateurs visuels et sonores.
Deux plages de détection: 70 à 1000V et 12 à 1000V.
Pointeur laser lumineux intégré.
Durability / Durabilidad / Durabili
Drop Protection
Protección ante caídas / Protection contre les chutes
9.8 ft.
(3 m)
Safety Rating
Clasificación de seguridad / Cote de sécurité
CAT IV
1000V
Symbols on tester / Símbolos del probador / Symboles sur le testeur
Warning – Risk of electric shock / Advertencia: riesgo de choque eléctrico /
Avertissement – Risque d'électrocution
Risk of danger. It is important that users of this tester read, Important information:
understand, and follow all warnings, cautions, safety information, and instructions
in this manual before operating or servicing this tester. Failure to follow instructions
could result in death or serious injury.
Riesgo de peligro. Es importante que el usuario de Información importante:
este probador lea, comprenda y respete todas las advertencias, precauciones,
instrucciones e información de seguridad incluidas en este manual, antes de
poner en funcionamiento el probador o de realizarle servicios de mantenimiento.
No seguir estas instrucciones puede dar lugar a lesiones graves o mortales.
Risque de danger. Il est important que les utilisateurs Information importante:
de ce testeur lisent, comprennent et suivent tous les avertissements, mises
en garde, information de sécurité et instructions donnés dans le présent guide
avant de faire fonctionner ou de réparer ce testeur. Le non-respect pourrait
entraîner des blessures graves, voire la mort.
Double insulated / Doble aislamiento / Double isolation
This product has been independently tested by Intertek and meets applicable
published standards.
Este producto p1-ha sido probado de manera independiente por Intertek y
cumple con las normas publicadas vigentes.
Ce produit a été tes de manière indépendante par Intertek et pond aux
exigences des normes applicables.
CAT
IV
For measurements performed at the source of low-voltage installation and outside lines.
Para mediciones realizadas en la fuente de la instalación de bajo voltaje y líneas externas.
Pour des mesures prises à la source d’une installation à faible tension et des lignes extérieures.
70 1000V AC
12 1000V AC
DUAL-RANGE
GENERAL SPECIFICATIONS
The Klein Tools NCVT-5 is a dual-range non-contact voltage tester
(NCVT) with laser pointer. It can be set to detect voltage from 70 to
1000V AC (Mode 1) or from 12 to 1000V AC (Mode 2). The laser
pointer can function independent of or simultaneously with the NCVT.
Measurement Range: Mode 1: 70 to 1000V AC
Mode 2: 12 to 1000V AC
Frequency Range: 50 to 500 Hz
Laser: Class IIIa, 630 to 670nm, Max. Power <5mW
Batteries: 2x AAA 1.5V Alkaline
Operating and Storage Altitude: Up to 6562 ft. (2000 m)
Operating and Storage Temp: ° ° ° °14 to 122 F (-10 to 50 C)
Relative Humidity: <95% non-condensing
Dimensions: 6.0" x 0.96" x 1.16" (152 x 24 x 29 mm)
Weight: 2.5 oz. (72 g) including batteries
Pollution degree: 2
Safety Rating: CAT IV 1000V AC
Drop Protection: 9.8 ft. (3 m)
Standards: Conforms to UL STD. 61010-1, 61010-2-030
Certi ed to
CSA STD. C22.2 No. 61010-1, 61010-2-030
Complies with: 21 CFR 1040.10 and 1040.11 except for deviations
pursuant to laser notice No. 50, dated June 24, 2007.
Specifications subject to change.
WARNING: Cancer and reproductive harm See www.P65Warnings.ca.gov for more information.
FIG. 1
NCVT-5
DUAL-RANGE NON-CONTACT
VOLTAGE TESTER WITH
LASER POINTER
PROBADOR DE VOLTAJE
SIN CONTACTO DE RANGO
DUAL CON PUNTERO LÁSER
TESTEUR DE TENSION
SANS CONTACT À
DOUBLE PLAGE AVEC
POINTEUR LASER
WARNINGS AND INSTRUCTIONS INSIDE - DO NOT DISCARD.
ADVERTENCIAS E INSTRUCCIONES EN EL INTERIOR - NO DESECHAR.
AVERTISSEMENTS ET INSTRUCTIONS À L’INTÉRIEURNE PAS JETER.
CAT IV
1000V
Warranty / Garantía / Garantie :
www.kleintools.com/warranty
WARNINGS and instructions: See inside.
ADVERTENCIAS e instrucciones: ver en interior.
ADVERTISSEMENTS et instructions : Voir à l’inrieur.
2x AAA
INCLUDED
INCLUIDAS
COMPRISES
www.kleintools.com


Produkt Specifikationer

Mærke: Klein Tools
Kategori: Ikke kategoriseret
Model: NCVT-5

Har du brug for hjælp?

Hvis du har brug for hjælp til Klein Tools NCVT-5 stil et spørgsmål nedenfor, og andre brugere vil svare dig




Ikke kategoriseret Klein Tools Manualer

Klein Tools

Klein Tools 60822 Manual

26 September 2024
Klein Tools

Klein Tools 56416 Manual

26 September 2024
Klein Tools

Klein Tools 60821 Manual

26 September 2024
Klein Tools

Klein Tools 29602 Manual

21 September 2024
Klein Tools

Klein Tools BAT20GD1 Manual

3 September 2024
Klein Tools

Klein Tools BAT20GD10 Manual

3 September 2024
Klein Tools

Klein Tools 29201 Manual

31 August 2024

Ikke kategoriseret Manualer

Nyeste Ikke kategoriseret Manualer

Gigabyte

Gigabyte ODIN GT 550W Manual

23 November 2024
Stamos

Stamos S-PLASMA 60U Manual

23 November 2024
Velbus

Velbus VMBPIRO-W-20 Manual

23 November 2024
Honor

Honor 90 Pro Manual

23 November 2024
Honor

Honor 80 SE Manual

23 November 2024
Medela

Medela Safe & Dry Manual

22 November 2024
Jane

Jane First Potty Manual

22 November 2024