1
Welcome Message ....................................................................................................................................... 2
Introduction ............................................................................................................................................... 3-7
Main Features ............................................................................................................................................. 4
Specifications .......................................................................................................................................... 5-6
Warranty .................................................................................................................................................... 7
Safety Instructions........................................................................................................................................ 8
Front Panel .............................................................................................................................................. 9- 10
Back Panel .............................................................................................................................................. 11 15-
Accessories ........................................................................................................................................... 16 18-
Getting Started ........................................................................................................................................... 19
Installation ................................................................................................................................................ 19
Power Up ................................................................................................................................................. 19
Web App UI............................................................................................................................................ 20 27-
Connecting to the Network ......................................................................................................................... 21
Setting up the Web App UI ..................................................................................................................... 22-27
Saving Amplifier Settings ............................................................................................................................ 28
Loading Amplifier Settings ........................................................................................................................... 29
Saving Channel Speaker Tunings ................................................................................................................ 30
Loading Channel Speaker Tunings .............................................................................................................. 31
DSP Block Diagram ..................................................................................................................................... 32
Glossary ................................................................................................................................................. 33 35-
Power Consumption .............................................................................................................................. 36 38-
Support .................................................................................................................................................. 39 40-
Sustainability Statement ....................................................................................................................... 41 42-
Declaration of Conformity ......................................................................................................................... 43
Document Revision Date: February 4, 2020
© 2019 LEA Professional. All Rights Reserved.
2
We’ve been in the deep end of the pro audio industry for a long time now. What we saw was an
appetite for something new . So, we started LEA Professional a new pro audio technology
company with the freedom, agility, knowledge and pa create not only a great audio ssion to
amplifier, but also simple systems that focus on supporting you, our customer.
At the end of the day, we are just passionate about audio technology and we want to share our
passion with as many people as possible. Because we know that great audio technology, is at
the heart of great experiences. So, we are dedicated to providing perfect sound reinforcement
through all of our products.
We’re deeply proud of our Connect Series amplifiers and we can’t wait for you to get working
with them. We truly believe that we’ve produced the best looking, best performing product
with the best technology at the best price for you.
Although we’ve strived to create and proactive technologiessimple systems , we are dedicated
to continually supporting you with anything you need. Please don’t hesitate to contact us
anytime for more information, support, or just to talk audio.
As far as we’re concerned, we’re riding this wave together. Welcome aboard!
G e t
G e t
G e t
G e t G e t p r
p r
p r
p rp r o
o
o
oo
m o r e
m o r e
m o r e
m o r em o r e
j
j
j
jj o i n o u r
o i n o u r
o i n o u r
o i n o u ro i n o u r
a u d i o c o m m u n i t y !
a u d i o c o m m u n i t y !
a u d i o c o m m u n i t y !
a u d i o c o m m u n i t y !a u d i o c o m m u n i t y !
Follow:
@LEAProfessional
Follow:
@LEA_Professional
Subscribe:
l eaprofessional.com
© 2019 LEA Professional. All Rights Reserved.
4
Cloud control, monitoring, and notifications coming end of 2019
you can engage the built in WiFi access point, connect to the venue s WiFi, and use the FAST 10/100MB
Ethernet to connect to any local area network via Cat5 or Cat6 cable.
Then there’s the Cloud…The Network Connect Series is the first professional amplifier family to feature
Cloud connectivity. Harness the power of the Cloud for remote control, monitoring, notifications and more
from any of your personal devices – no software download needed! Just connect your amp to a network
and start commanding your systems. Register for your free LEA Cloud account at leaprofessional.cloud
The power of the Cloud and our Web UI will set the installer up to be able to create a recurring revenue
source by adding monitoring and preventative system maintenance to their service contracts. Also
included is an Analog Devices 96kHZ DSP with up to 48dB/Oct filters, 8 parametric EQ’s, speaker
protection limiting, and many more features controlled by a web-based UI.
The Network Connect Series also features analog inputs and external I/O control for remote on/off and
fault monitoring.
MAIN FEATURES
works on any device with no software to download Web Browser-based UI
(70V or 100V) selectable per channel Direct LoZ and HiZ
double the output power of any single channel without sacrificing Proprietary Smart Power Bridge
other channels on the amplifier
1.) Built in WiFi Access Point 2.) Connects to existing WiFi 3 Ways to Connect to the amplifier
network 3.) Local Area Network Ethernet connection
3rd Party API support for most of the industry leading system processors on the market
with Input Routing, multiple 48dB/Oct crossover filters, 8 Parametric EQ 96kHz Analog Devices DSP
filters, user configurable speaker limiters, and real time load monitoring
with PFC. Operation from 100VAC – 240VAC +/-10% Universal Switch Mode Power Supply
fully routable inputs with backup capabilities Analog
for Remote On/Off and fault monitoring External I/O Port
for low AC Current draw Highly Efficient Class D Output Stage
© 2019 LEA Professional. All Rights Reserved.
5
Connect Series 352 2 x 350 WRMS @ 4Ω, 8Ω, 70V, 100V (175W at 2Ω)
Connect Series 702 2 x 700 WRMS @ 4Ω, 8Ω, 70V, 100V (350W at 2Ω)
Audio Spec
Inputs Analog: Balanced Inputs with user selectable 26 dB and 34 dB input sensitivity (2CH = 2 inputs, 4CH=4
inputs, 8CH = 8 inputs)
THD+N 0.1% (20Hz to 20kHz)
Frequency
Response
+/- 0.5 dB @ 4Ω, 8Ω, 70V, 100V, -2.5dB @ 20kHz at 2Ω
Signal to Noise
Level
105dB (20Hz to 20kHz referenced to 8Ω)
Crosstalk 70dB (20Hz to 20kHz)
I/O Latency 1 ms DSP latency under any condition
Load Impedance LowZ down to 2 ohms, 70V direct, and 100V Direct per channel
Amplifier Output
Classification
Class D with Proprietary Smart Power Bridge Technology allowing bridged output functionality without
sacrificing an amplifier channel
DC Offset +/- 3mV
DSP
DSP Architecture Analog Devices Sigma 96kHz DSP Processor with 32-bit Core with Sample Rate Converters
Input Matrix Routable matrix; any input to any output with primary and secondary input priority
Crossovers Up to 48 dB/Octave IIR Filters (Linkwitz Riley, Butterworth)
Parametric EQ 8 Band Parametric EQ per channel
Output Delay 100ms per channel
Output Protection DC, VHF, and AC Mains Protection, Overtemp and Current Limiter, fan fault detection
User Adjustable
Limiting
Peak Voltage and RMS Voltage
Load Monitoring Realtime Load Monitoring and Pilot Tone Detection from Internal or External Sources
Control,
Monitoring,
Network
Network
Connectivity
WiFi or 100MB Ethernet with PoE or Built in WiFi Access Point (IEEE 802.11
2.4GHz b/g/n WPA, WAP2, WEP)
User Interface Web Browser User Interface, 3rd Party API control, or CLOUD control
Supported
Operating Systems
MAC, iOS, PC, Android
Event Reporting User Downloadable and Viewable Event and Fault log - POE allows for enhanced error
monitoring
External I/O External I/O In: Toggles Remote On/Off
External I/O Out: Indicates
Amplifier Health
Cloud IoT Cloud based IoT functionality
Operation
AC Mains 100VAC - 240VAC +/- 10% 50Hz or 60Hz
Temperature Storage: -20°C to 90° C - Operating: 0°C to 55° C
Power Supply Universal Switch Mode Power Supply with Power Factor Correction (No PFC in
Connect
S
eries
84
,
C
onnect
S
eries
164
,
C
onnect
S
eries
88, &
C
onnect
S
eries
168
)
Safety Approvals UL, CSA,CE, ETL, FCC, CCC, KETI, NOM , ROHS, PSE
Physical
Spec
Dimensions (L x W
x H)
Product: 14.25” x 19” x 1U (362mm x 482mm x 1U
Shipping: 20” x 22.75” x 3.75” (508mm x 578mm x 95.25mm)
Weight
Connect Series 352 & Connect Series 702: 10lbs / 3.4kg | Shipping: 17.4lbs / 7.9kg
Connect Series 354 & Connect Series 704: 14lbs / 4kg | Shipping: 18.7lbs / 8.5kg
Connect Series 84 & Connect Series 164: 12.05lbs / 5.46kg | Shipping: 16.35lbs / 7.41kg
Connect Series 88 & Connect Series 168: 13.35lbs / 6.05kg | Shipping: 17.75lbs / 8.05kg
Cooling
Front to Rear Variable Fan Speed Cooling
Fan Noise at idle is 50dB @ 1m
Fan Noise at 50% is 57dB @ 1m
Fan Noise
at full speed
is
63
dB @ 1m
Connectors
Analog Input: 3 pin Amphenol Anytek, Output: 2 pin Amphenol Anytek, External IO: 3 pin Amphenol Anytek,
Power in: IEC, Ethernet RJ45 In for Control ***Note: Connect Series 84, Connect Series 164, Connect
S
eries
88, &
C
onnect
S
eries
168
do not have potentiometers on the rear pane
The Connect Series’ WiFi connectivity is achieved using the Japanese certified wireless module ATWILC1000
-
MR110UB.
© 2019 LEA Professional. All Rights Reserved.
6
Front to back airflow
(See page for fan noise)previous
1.72” /
43.7mm
14.2” /
360.7mm
© 2019 LEA Professional. All Rights Reserved.
7
y , p y
distributor which can be found here: www.leaprofessional.com/partner map-
Excluded Items: This Warranty does not cover any product which has been damaged because of any
misuse, mishandling, accident, or negligence. This LEA LLC Warranty is not valid if the product serial
number has been defaced, altered, or removed. LEA LLC liability shall be limited to the actual purchase
price of any defective unit or units of LEA LLC equipment to which a claim is made, and shall in no
event include the Customers’ installation costs, design costs, lost profits or goodwill, or any other direct,
indirect, special, incidental or consequential damages.
LEA LLC Obligations: LEA LLC will remedy any defective product (except as excluded), by advanced
replacement with new or equivalent factory refurbished product during the initial three -year warranty
period. LEA LLC will provide ground shipment for the replacement product free of charge. LEA LLC
will issue a return shipment call tag for the defective unit when RMA is requested.
Making a Warranty Claim: A claim for Warranty must be submitted through the original selling dealer.
The dealer must notify LEA LLC of the need for Warranty replacement via LEA LLC’s online partner
portal. Once Warranty is verified, an RMA number will be provided along with a return shipment call tag.
All components must be returned in LEA LLC factory packaging with the RMA number clearly visible
on the return shipping label. If a defect product is not returned within 14 days of RMA issuance, the
dealer will be billed the full dealer price of the replacement unit. Should a customer wish to have a
product repaired and returned instead of replaced, customer should contract LEA Customer Care team
for
return instructions.
Alterations: No person has the authority to extend, amend, or modify this LEA LLC Warranty.
Replacement product provided under the terms of this LEA LLC Warranty shall carry only the unexpired
portion of Warranty of the originally purchased product.
Design Changes: LEA LLC reserves the right to change the design of any product from time to time
without notice and with no obligation to make corresponding changes in products previously
manufactured.
Country where Purchased: LEA LLC Warranty is only available in the country of the products original
purchase.
© 2019 LEA Professional. All Rights Reserved.
8
3. Heed all warnings provided in these instructions .
4. Follow all instructions document found in this .
5. waterKeep this unit away from at all times.
6. Use only a dry cloth to clean the unit.
7. Do not block any ventilation openings. Follow the
installation instructions from this manual for proper
ventilation.
8. Never install this unit near a heat source such as
furnace, ovensradiator, heat registers, , or other
anything else that produces heat.
9. Do not the safety purpose of the polarized oralter
grounding provided- type plug. If the plug does not fit
into your outlet, consult an electrician.
10. Keep the power cord away from areas at risk of
being walked on, tripped over, or pinched.
11. Only use attachments/accessories specified within
this document.
12 . Unplug this device during lightning storms or
when unused for long periods of time.
13. Do not attempt to service this unit. All servicing
must be performed by a qualified LEA service
technician. To find a qualified LEA technician, contact
your local LEA dealer/distributor.
14 . To disconnect the device from the mains, use the
mains plug.
15. WARNING: DO NOT EXPOSE THIS
APPARATUS TO RAIN OR MOISTURE. DOING SO
CAN RESULT IN AN ELECTRAL SHOCK.
16 - OBJECTS, . ENSURE THAT NO LIQUID FILLED
SUCH AS DRINKING WATER, ARE PLACED ON
THE EQUIPMENT. KEEP EQUIPMENT AWAY
FROM DRIPPING OR SPASHING.
17. THE MAINS PLUG OF THE POWER SUPPLY
CORD SHALL REMAIN READILY OPERABLE.
MAGNETIC FIELD
CAUTION! All - high gain devices such as preamplifiers
should be installed away from the Due to thedevice.
high power- density of this amplifier, it has a strong
magnetic field which can induce hum into unshielded
devices that are located nearby. The field is strongest
just above and below the unit. If an equipment rack is
used, we recommend in the installing the amplifier(s)
bottom of the rack and the preamplifier or other
sensitive equipment at the top.
BE AWARE OF THESE SYMBOLS:
The exclamation point alert is used to
inform ofthe user
important operating or maintenance
instructions
DO NOT REMOVE TOP OR
BOTTOM COVERS ON THIS DEVICE. NO USER
SERVICEABLE PARTS INSIDE.
CONTACT FOR QUALIFIED SERVICE PERSONNEL
ALL SERVICING MATTERS.
FCC COMPLIANCE NOTICE
This device complies with part 15 of the FCC rules.
Operation is subject to the following
two conditions: (1) This device may not cause harmful
interference, and (2) this device
must accept any interference received, including
interference that may cause undesired
operation.
CAUTION: Changes or modifications not expressly
approved by the party responsible for compliance
could void the user’s authority to operate the
equipment.
NOTE: This equipment has been tested and found to
comply with the limits for a Class B digital device,
pursuant to part 15 of the FCC Rules. These limits are
designed to provide reasonable protection against
harmful interference in a residential installation. This
equipment generates, uses, and can radiate radio
frequency energy and, if not installed and used in
accordance with the instruction manual, may cause
harmful interference to radio communications.
However, there is no guarantee that interference will
not occur in a particular installation. If this equipment
does cause harmful interference to radio or television
reception, which can be determined by turning the
equipment off and on, the user is encouraged to try to
correct the interference by one or more of the
following measures:
• Reorient or relocate the receiving antenna.
• Increase the separation between the equipment and
receiver.
• Connect the equipment into an outlet on a circuit
different from that to which the
receiver is connected.
• Consult the dealer or an experienced radio/TV
technician for help
© 2019 LEA Professional. All Rights Reserved.
10
LEA Shark Fin
Illuminates green with AC plugged in & blue with
AC plugged in and powered on when .
The Amp Front Panel:
I ndicator Definitions:
Channel Fault Indicates the channel has shut down due to protection circuits. Check to make sure the output on
that channel is not shorted. If all channels indicate fault, the power supply has gone into protection. No audio will be
passed until the fault is resolved.
Channel Thermal Indicates channel is at or close to over temp. When dim, the channel will start to lightly limit the
output. When bright, the channel is heavily limiting the output.
Channel Clip – A red light indicates the channel is at the onset of audible clip on the output. Excessive clipping can
damage the speaker connected to the amplifier. If the LED is Amber, that indicates the channel is limiting.
Signal Presence -This indicator illuminates when there is 40db of input signal present on that assigned output
channel.
Channel Ready – Indicates the channel is ready to pass audio. If this indicator is off, the channel may be in standby
mode or the amplifier DSP is booting up.
Easy Pop out Grill e
Removable front grilles
w s ith washable foam filter
Front Panel LCD
Shows IP Address, Amp Name, SSID when in
WiFi Access Point Mode, and MAC Address
Channel Status Indicator
Channel Fault
Channel Thermal
Channel Clip
Signal Presence
Channel Ready
© 2019 LEA Professional. All Rights Reserved.
17
Authorized U.S. Dealers, U.S. and International Distributors can access parts and service requests from the online sales portal at
www.leaprofessional.shop
If you are not an Authorized Dealer or Distributor, please contact the U.S. Dealer, U.S. or International Distributor in your country where you purchased
the product and they can assist you – www.leaprofessional.com/partner-map
2 CHANNEL KIT | Connect S Connect Series 352/ eries 702
IEC Power Cord
Quick Start Guide
Record of Excellence
Welcome Card
Sticker
(2) Removable/Washable front panel Foam Filters
(3) 3 position 5.08mm Amphenol Anytek Input
Connectors 2| ( ) for analog input, (1) for External
I/O Port
(2) 2 position 7.62mm Amphenol Anytek Output
Connectors
(4) Rack Screws (standard)
Rack Supports (2) Rear
4 CHANNEL KIT | Connect S / Connect Series 84 eries 164
IEC Power Cord
Quick Start Guide
Record of Excellence
Welcome Card
Sticker
(2) Removable/Washable front panel Foam Filters
(5) 3 position 5.08mm Amphenol Anytek Input
Connectors | (4) for analog input, (1) for External
I/O Port
5.08(4) 2 position mm Amphenol Anytek Output
Connectors
(4) Rack Screws (standard)
(2) Rear Rack Supports
4 CHANNEL KIT | Connect S 4/ Connect S 4eries 35 eries 70
IEC Power Cord
Quick Start Guide
Record of Excellence
Welcome Card
Sticker
(2) Removable/Washable front panel Foam Filters
-(5) 3 position 5.08mm Amphenol Anytek Input
Connectors External | (4) for analog input, (1) for
I/O Port
(4) 2 position 7.62mm Amphenol Anytek Output
Connectors
(4) Rack Screws (standard)
(2) Rear Rack Support
8 CHANNEL KIT | Connect S / Connect Series 88 eries 168
IEC Power Cord
Quick Start Guide
Record of Excellence
Welcome Card
Sticker
(2) Removable/Washable front panel Foam Filters
(9) 3 position 5.08mm Amphenol Anytek Input
Connectors 8| ( ) for analog input, (1) for External
I/O Port
(8 5.08 Output ) 2 position mm Amphenol Anytek
Connectors – 80W/160W
(4) Rack Screws (standard)
(2) Rear Rack Supports
© 2019 LEA Professional. All Rights Reserved.
18
2-Position Amphenol Anytek
Output Connector
LEA Part #: CPP10001-1
350/700W Only*
2-Position Amphenol Anytek
Output Connector
LEA Part #: CPP10006-1
80/16 * 0W Only
3-Position Amphenol Anytek
Input Connector
LEA Part #: CSP10006-1
3-Position Amphenol Anytek
Input Connector
LEA Part #: CSP10001-1
10-32 Rack Screw
LEA Part #: MSI10007-1
Rear Rack Support
LEA Part #: MFM10003-1
Foam Air Filter
LEA Part #: MDF10001-1
© 2019 LEA Professional. All Rights Reserved.
21
1. -Built in Wi Fi Access Point (WAP)-
The built in Wi Fi access point allows for a point point connection. This means you will only be able to - - -to
communicate to one Connect Series ampli er at a timefi .
Using WAP
1. -Press Wi Fi button on rear panel to activate Wi Fi Access Point-
2. Once enabled, the front LCD now displays an SSID and IP address
3. Connect your device (phone, tablet, computer) to the Fi networkamplifier’s Wi-
4. Enter the IP address from the front panel LCD into your device’s web browser
5. Control and monitor via the built in web - browser based- UI
NOTE: If a Cat5 or Cat6 cable is plugged in, WAP mode is disabled. Remove the Cat cable when entering AP mode.
Dante connections can stay plugged in.
2. 10/100MB FAST Ethernet
In 10/100MB FAST Ethernet Mode, you will be able to see multiple amplifiers in the Web Browser Based
UI.
Using 10/100MB FAST Ethernet
1. Connect via wired network using Cat5 or Cat6 cable
2. Once connected, the front LCD now displays an IP address
3. Connect your device (phone, tablet, computer) to the Local Area Network and enter the IP
address from the front panel LCD into your device’s web browser
4. Control and monitor via the built-in web browser-based UI
NOTE: Out of the box, the factory default settings require the amplifier to be connected to a DHCP switch.
3. Local Area Wi Fi Network-
Connecting multiple amplifiers to the venue’s Wi Fi network allow you to see multiple amplifiers in the -
Web Browser Based UI.
Using Local Area Wi-Fi
1. Connect to the Web App UI (same as WAP instructions above) then navigate to networking menu
2. Check the “Wi-Fi Enabled” box
3. Type in existing Wi Fi network’s SSID that you would like to- connect to (case sensitive)
4. Enter password if necessary, to see amp’s IP address, subnet mask, and gateway info confirming
your status and click “Save”
5. Connect your device (phone, tablet, computer) to the existing Wi Fi network you have selected for -
the amp
6. Control and monitor via the built in web browser based UI- -
NOTE: only one connection method is available for remote connection. If Wi-Fi is enabled, the ethernet connection is shutdown.
Vice versa is also true.
© 2019 LEA Professional. All Rights Reserved.
22
Therefore, you can see which amps are online/offline, whether they are powered on or in a standby
mode, a quick performance status to report any errors or faults and even more.
In addition, with one click, you can view the status of every channel on any given amp to quickly monitor
channel performance. Such as your output meter with a clip indicator, status indicators such as Ready,
Limiting, Thermal, and Fault, as well as a quick attenuation level view and channel mute button.
So then, with a second click, you can select an individual channel for control and monitoring. Lastly, with
a third click you are ready to start viewing and adjusting channel settings such as Input Settings, Signal
Generator, Crossover, Equalizer, Limiter, and Load Monitoring.
LEA Professional
Amp#123
AP: Amp- 123
10.8.3.205
FIND THE IP ADDRESS DISPLAYED
ON THE FRONT PANEL SCREEN.
2.
ENTER IP ADDRESS IN YOUR
DEVICE’S WEB BROWSER SEARCH
BAR.
CONTINUE TO NEXT PAGE…
1.
© 2019 LEA Professional. All Rights Reserved.
23
3.
IF THE AMPLIFIER HAS ALREADY BEEN
SETUP WITH A PASSWORD, YOU WILL
SEE THIS LOGIN SCREEN. ONCE THE
CORRECT PASSWORD IS ENTERED (OR
IF GUEST MODE IS SELECTED) YOU
WILL BE TAKEN TO THE HOME SCREEN
SHOWN ABOVE.
FIRST-TIME USERS WILL
IMMEDIATELY SEE THIS SCREEN. THIS
IS THE SYSTEM HOME SCREEN
WHICH DISPLAYS ALL DEVICES
CONNECTED TO THE NETWORK.
NOTE: GUEST MODE IS READ-ONLY AND YOU
WILL NOT BE ABLE TO MAKE ANY CHANGES
© 2019 LEA Professional. All Rights Reserved.
24
RED BAR
Indicates the
amp is offline
GREEN BAR
Indicates the
amp is online
State 1 The amplifier is in a
completely powered up state.
State 2The amplifier is in
auto-standby mode.
d
State 3The amplifier is in
remote on/off mode and has
POE active.
State 1Normal operation.
No errors or faults reported.
State 3The amp is reporting
a fault.
State 2Amp reporting an
event but no faults..
State 2
Amp connected via
rear panel ethernet
connection.
State 1
Amp connected to Wi-Fi
Access point of venue’s
Wi- Fi
State 1
No channels
muted
State 2
All channels
muted
State 3
Some channels
muted, some
channels not muted.
Shortcut to
Green Menu
screen.
Shortcut to
“Amp Info
screen.
POWER STATES - 3 STATES
AMP STATUS – 3 STATES
NETWORK - 2 STATES
OTHER
© 2019 LEA Professional. All Rights Reserved.
25
Pressing the “I” icon
will activate a popup
menu with multiple
amp info screens.
Pressing the power
cord with a leaf icon
brings you to the
“Green Menu” page.
Pressing the Wi-Fi
or LAN icon brings
you to the “Network
Settings” page.
Pressing the
distressed face
emoji brings you to
the “Faults Log”
page.
Pressing the
frowning face emoji
brings you to the
“Events Log” page.
Pressing the smiley
face emoji brings
you to an expanded
view of all of the
amp’s channels.
© 2019 LEA Professional. All Rights Reserved.
26
CH 1 Output Mute
CH 1 Output Meter
CH 1 Ready Indicator
CH 1 Limiting Meter
CH 1 Attenuation
(always read only)-
CH 1 Output
Clip Indicator
CH 1 Fault Indicator
CH 1 Thermal
Indicator
Mute/Unmute all CH
© 2019 LEA Professional. All Rights Reserved.
28
CLICK THE “i” ICON FROM THE
AMP’S MAIN SCREEN.
1. 2. SELECT “ADVANCED” FROM
THE POPUP MENU.
PRESS “EXPORT AMP
SETTINGS
3.
4.
A FILE WILL BE DOWNLOADED
TO YOUR MAC, WINDOWS PC,
OR ANDROID DEVICE.
*IOS download coming soon.
© 2019 LEA Professional. All Rights Reserved.
29
CLICK THE “i” ICON FROM THE
AMP’S MAIN SCREEN.
1. 2. SELECT “ADVANCED” FROM
THE POPUP MENU.
PRESS “IMPORT AMP
SETTINGS
3.
4.
SELECT YOUR FILE TO
IMPORT THEN CHECK EACH
BOX YOU DESIRE AND CLICK
IMPORT.
NETWORK SETTINGS
This check box will load the
following information: WiFi –
SSID, SSID Password, DHCP or
Static. If Static IP, address and
Gateway will be loaded.
Ethernet – DHCP or Static. If
Static, IP address and Gateway
will be loaded.
CHANNEL SETTINGS
This check box will load the
following information for each
channel: All settings for - Input
Section, Signal Generator,
Crossover, Parametric EQ,
Limiter and Load Pages.
AMP SETTINGS
This check box will load the
following information: Amp
Name, Venue Name, Rack
Name, Rack Position, Installer
Name, Installer Contact Info,
Date of Installation, Asset Tag
Number, Power Supply Settings,
and Auto Standby Settings.
© 2019 LEA Professional. All Rights Reserved.
30
FROM THE
AMPLIFIER MAIN
SCREEN, SELECT
WHICH CHANNEL
YOU WISH TO SAVE
TUNINGS FROM.
1. 2. NAVIGATE TO THE
CROSSOVER SETTINGS PAGE
AND SELECT “EXPORT”.
SELECT “EXPORT” AGAIN AND
YOUR SETTINGS WILL BE
DOWNLOADED TO YOUR
DEVICE.
3.
THE DOWNLOAD FILE WILL
CONTAIN ALL CHANNEL
INFORMATION FROM THE
INPUT PAGE, SETTINGS PAGE,
SIGNAL GENERATOR PAGE,
CROSSOVER PAGE,
PARAMETRIC EQS PAGE,
LIMITERS PAGE, AND LOAD
MONITORING PAGE.


Produkt Specifikationer

Mærke: LEA
Kategori: Modtager
Model: Connect 704

Har du brug for hjælp?

Hvis du har brug for hjælp til LEA Connect 704 stil et spørgsmål nedenfor, og andre brugere vil svare dig




Modtager LEA Manualer

LEA

LEA Connect 704 Manual

21 August 2024
LEA

LEA Connect 702 Manual

21 August 2024
LEA

LEA Connect 352 Manual

19 August 2024
LEA

LEA Connect 704D Manual

19 August 2024
LEA

LEA Connect 702D Manual

19 August 2024
LEA

LEA Connect 354D Manual

18 August 2024
LEA

LEA CS354D-G Manual

18 August 2024
LEA

LEA Connect 88D Manual

18 August 2024
LEA

LEA CS704-G Manual

18 August 2024
LEA

LEA CS704D-G Manual

18 August 2024

Modtager Manualer

Nyeste Modtager Manualer