Performance Data
Maximum supply pressure - 170 PSIG
Minimum operating pressure - 17 PSIG
Maximum BTU - 500,000
Minimum cylinder size - 20 lbs.
Safety Precautions:
Read and understand all warnings and instructions before attempting to operate the equipment.
Never permit children to use this torch.
Warning:
Flames from this torch can cause serious burn injuries to your skin and body.
Blocking flame at torch head may cause flame direction to reverse and exit from the top of
the torch head toward the operator.
Using this torch on or near flammable material or closed containers may cause a fire or
explosion which may cause injury or death.
Failure to control burning material while using this torch may cause injury or property damage.
Personal Protective Equipment:
• Always wear eye protection such as safety goggles or glasses which meet ANSI Z87.1, heavy
gloves, leather shoes and heavy cotton clothing treated to be fire retardant. Do not wear shorts or
loose clothing.
Equipment Precautions:
Only use this torch with propane gases from vapor withdrawal cylinders. Do not attempt to use
fuel gas other than approved propane fuels.
Propane cylinders must be kept in an upright position especially when the torch is in use.
Before use, check all equipment for leaks with an approved bubble solution. Do not light torch
until any and all leaks are repaired.
Light torch only with an approved lighter (provided). Do not use matches or a cigarette lighter.
Do not permit lighted cigarettes, sparks or open flames near this equipment.
When not in use, close torch valve and cylinder valve.
Do not abuse, tamper with or alter the operation of this torch or its parts. Any repairs must be
made by a qualified repair technician.
Use of Equipment:
When operating the torch, always have a helper with proper NFPA approved fire extinguisher (or
other fire fighting apparatus) of a type and size appropriate for the application and trained in its
use nearby to watch and control the burning material.
Maintain secure footing when holding a lighted torch to avoid falling. Shut torch and tank valves
off if you are moving more than a few yards.
• Always direct flame from the torch away from your body when torch is lighted. Never point the
torch at yourself or other persons while lighting or operating. Keep other persons away from the
torch at all times.
Never leave a lighted torch unattended. Turn the torch valve off to extinguish the flame before
laying the torch down. Do not lay a hot torch down on or near flammable material.
Do not block the flow of air or fuel gas through the torch head. Never allow the torch head to
contact a surface or block the flow of gas from the torch head. Doing this may cause flame direc-
tion to reverse and exit from the top of the torch head toward the operator. Lift torch head from
surface immediately if this occurs and release safety lever valve.
Do not use torch in areas where combustible gases or vapors may be stored or otherwise present.
Do not use this torch on or near flammable material or sealed containers which may cause a fire
or explosion resulting in injury or death. Sealed containers even if empty, may explode.
Only burn in a small area at one time. Do not use torch near combustibles you do not intend to burn.
Do not use the torch in windy or very dry conditions in which the torch flame or the amount of
material burning may be difficult to control.
In some locations you may not be permitted to burn without a permit. Contact your local authori-
ties and fire department about state and local codes or permit requirements before using torch.
Torch head will remain hot for a time after shutdown. DO NOT touch or store the equipment
until it has cooled.
Warning:
• Burning or heating some materials can produce dangerous fumes which may cause
injury to your lungs or other parts of your body.
Only use this equipment outside or, if inside, only use for heating materials in a large area
with enough ventilation to avoid the build up of smoke, fumes and gases. If the air is not
clear and free of smoke, fumes and gases, stop using the torch and move the work outside or
improve the ventilation.
Propane fumes may collect in an unventilated or enclosed area causing an explosive atmos-
phere or one in which you cannot safely breathe.
Never use the torch on materials, coatings, solvents or chemicals which release toxic fumes
when heated or on plants such as poison ivy or poison oak.
• Avoid breathing smoke or fumes from burning material.
Keep your head out of the smoke or fumes.
If the smoke or fumes make you uncomfortable, stop using the torch on the material.
Warning: this product contains or produces a chemical known to the State of
California to cause cancer and birth defects of other reproductive harm (California Health &
Safety Code 25249.5 et. seq.)
For additional information regarding the safe use of this product see the following reference
publications:
NFPA/ANSI 58 - "Standard For The Storage and Handling of propane Gases" available from the
National Fire Protection Association
ANSI/ASC Z49-1 - "Safety in Welding and Cutting" available from the American Welding Society
CSA 2-94 - "U.S. Requirements for Hand Held LP Torches For Use With Fuel Supply" available
from the Canadian Standards Association
Instructions:
Set up/Assembly Instructions
1. Close all valves on torch and tank.
2. Always inspect equipment for damage before each use - Do Not Use if Damaged.
3. Remove plastic cap from hose fitting and attach hose fitting to propane tank-tighten properly
with wrench. Save plastic cap for reuse when torch is disassembled for storage.
4. If for some reason hose fittings have been disassembled from torch fittings for repair or replace-
ment - connections must be sealed with PTFE Teflon tape and leak tested before use.
5. Check all fittings for leaks with an approved bubble solution. Do not light torch until any and all
leaks are repaired. If you cannot eliminate leaks by carefully tightening the threaded fittings, have
the torch tested and repaired by a qualified repair technician.
Lighting Instructions
Important Equipment Notes
The cylinder connection on the Inferno torch is equipped with a safety device to prevent excess
flow of gas from improper use or certain equipment damage or failure.
The excess flow adapter may activate and reduce flow through the torch to a minimum if the
cylinder valve is opened too quickly and/or if the torch valve has been opened too far.
The Inferno torch is also equipped with an automatic shut off safety lever valve that will stop the
flow of gas and extinguish the flame if the lever is released during operation.
1. Close all valves.
2. Open cylinder valve slowly.
3. Point torch away from persons and/or any flammable materials.
4. Open torch adjusting valve about 1/8 of a turn or until a small amount of gas is heard escaping
when the safety lever valve is depressed.
5. Ignite torch by using the igniter supplied with the torch. DO NOT USE MATCHES OR CIGA-
RETTE LIGHTER.
6. If gas shows signs of restricted flow, the excess flow adapter may have activated. To reset:
a) Release safety lever valve and close cylinder valve.
b) Depress safety lever to bleed off residual pressure. Release lever.
c) Wait 10 - 20 seconds.
d) Open cylinder valve slowly once again, depress safety lever valve and ignite.
7. If torch continues to not operate properly, turn all valves off and check tank to be sure it is not
empty and has enough propane. If the tank is not empty, the problem may be in the torch. Have
the torch tested and repaired by a qualified repair technician or replace the torch.
8. Adjust torch with the torch adjusting valve to control flame intensity
9. Follow all instructions and warnings
Shut-down Instructions
1. Release safety lever valve to extinguish flame
2. Close cylinder valve
3. Depress and release safety lever valve to bleed residual gas pressure. Then close torch adjust-
ing valve.
Equipment Disconnection and Storage
Disconnection
1. Close all valves
2. Bleed off residual gas pressure on equipment as described in shut down instructions.
3. Disconnect hose fitting from propane tank and replace the plastic cap on the hose fitting to pro-
tect it from damage. It is important to protect the threaded fitting from damage so it does not leak
when connected to the propane tank.
Storage
1. Do not store torch while still hot
2. Store equipment in clean, dry protected area
3. Store cylinder according to NFPA/ANSI 58
Spanish and French version of warning label available at 866-236-0044.
Torch Adjusting Valve
Safety Lever Valve
Excess Flow Adapter
INFERNO TORCH
Torch Head
The Inferno Torch KH825
Instruction Manual
9500447


Produkt Specifikationer

Mærke: Lincoln Electric
Kategori: Ikke kategoriseret
Model: Inferno Torch KH825

Har du brug for hjælp?

Hvis du har brug for hjælp til Lincoln Electric Inferno Torch KH825 stil et spørgsmål nedenfor, og andre brugere vil svare dig




Ikke kategoriseret Lincoln Electric Manualer

Ikke kategoriseret Manualer

Nyeste Ikke kategoriseret Manualer