Lowell ACR-SEQ4-1509 Manual

Lowell Ikke kategoriseret ACR-SEQ4-1509

Læs nedenfor 📖 manual på dansk for Lowell ACR-SEQ4-1509 (3 sider) i kategorien Ikke kategoriseret. Denne guide var nyttig for 11 personer og blev bedømt med 4.5 stjerner i gennemsnit af 2 brugere

Side 1/3
Lowell strives to provide accurate information while reserving the right to change specications and/or improve manufacturing methods without prior notication.
©2021 Lowell Manufacturing Co., 100 Integram Dr., Pacic MO 63069 / tel. 800.325.9660 / www.lowellmfg.com
Spec 1606
Model ACR-SEQ4-1509 Rev. 04-30-21 | pg. 1/3
INTERNAL USE ONLY: PN 24208
DESCRIPTION:
Model ACR-SEQ4-1509 power distribution panel with sequencer
features nine NEMA outlets—six switched (controlled by power
switch for sequential activation/deactivation) and three unswitched
(always on). All outlets are clearly marked to assist the integrator
with connections. Color coded LEDs show sequencing status.
This panel can also be activated and deactivated by a remote
switch or alarm system that's connected to the plug-in barrier strip
terminal blocks in the back of the panel.
The compact steel chassis with black powder epoxy nish is
designed to occupy minimal rack space with overall dimensions of
19"W x 9"D x 1.75"H (1U). Termination is via an attached nine foot
power cord with NEMA 5-15P plug.
FEATURES:
Outlets: Unit features a total of nine NEMA outlets, which are
either switched (controlled by switch) or unswitched (always on).
Front Outlet:
NEMA 5-15R (1 unswitched single)
Rear Outlets:
NEMA 5-15R (2 unswitched single, 2 switched single,
2 switched duplex)
Activation & Sequencing:
The front rocker style power switch has momentary contacts
(normally open SPST) plus rear barrier strip termination blocks
for momentary (normally open) remote switches.
The switch initializes a four-step delayed start up sequence,
activating the switched outlets. A green LED ashes while
the unit is powering up and holds steady when the cycle is
complete. The switch also initializes the four-step delayed
shut down sequence, deactivating the switched outlets in
reverse order. A red LED ashes while the unit is powering
down and holds steady when the cycle is complete. Delay
between steps can be adjusted with a screwdriver (0.5–10
seconds).
Connections for External Controls: Plug-in barrier strip terminal
blocks in the rear of the panel allow external controls to activate
and deactivate the switched outlets.
Left Terminal Block—input from Alarm System: Lock On,
Lock Off, and Switch Lock for alarm system or master control
panel.
Right Terminal Block—input from Remote Switch:
Connect switch with momentary closure.
120VAC, 60Hz, 15A, 1800WPower Rating:
EMI/RFI Filter: 19dB@500Hz, 42dB@30MHz
Circuit Breaker Protection: 15A breaker with reset switch
Attached 9-ft. cord with NEMA 5-15P plugPower Cord:
19"W x 9"D x 1.75"H (1U), 10 lbs.Chassis:
Certication: ETL Listed in US/Canada (UL60065)
Country of Origin: Made in the U.S.A. with global components
A&E SPECIFICATIONS:
The rackmount power distribution panel with sequencer shall be
Lowell Model ACR-SEQ4-1509. It shall feature a total of nine (9)
NEMA 5-15R outlets including six (6) switched in rear, two (2)
unswitched in rear, and one (1) unswitched in front. A rocker style
switch on the front panel shall activate the switched outlets in four
steps, and deactivate them in reverse order. The delay between
steps shall be screwdriver adjustable (0.5 to 10 seconds). Color
coded LEDs shall indicate sequencing status. The panel shall have
a power rating of 120VAC, 60Hz, 15A with EMI/RFI ltering. It
shall include a 15A system circuit breaker with reset button. The
19"W x 9"D x 1.75"H (1U) steel chassis shall have a black powder
epoxy nish. Termination shall be via an attached 9 ft. cord with
NEMA 5-15P plug.
AC Power Distribution Panel w/Sequencer: ACR-SEQ4-1509
Rear view
Front view
System
circuit
breaker
NEMA
5-15R single
(unswitched)
Power
status
Power
switch
Sequence
status
Delay
adjust
Made in USA
Power cord
(attached) NEMA
5-15R single
(unswitched)
NEMA
5-15R single
(switched)
Step 2
NEMA
5-15R duplex
(switched)
Step 4
INPUT
from
alarm
system
INPUT
from
remote
switch
NEMA
5-15R single
(unswitched)
NEMA
5-15R single
(switched)
Step 1
NEMA
5-15R duplex
(switched)
Step 3


Produkt Specifikationer

Mærke: Lowell
Kategori: Ikke kategoriseret
Model: ACR-SEQ4-1509
Tænd-/slukkontakt: Ja
Vekselstrømsindgangsfrekvens: 60 Hz
Bredde: 482.6 mm
Dybde: 228.6 mm
Højde: 44.45 mm
Vægt: 4535 g
Produktfarve: Sort
LED-indikatorer: Ja
Kabellængde: 2.74 m
Maksimal ydeevne: 1800 W
Strømstik: NEMA 5–15P
Nominel indgangsspænding: 120 V
AC udgange, antal: 9 AC stikkontakt(er)
AC stikkontakt typer: NEMA 5–15R
Rackkapacitet: 1U
Strøm (maks.): 15 A

Har du brug for hjælp?

Hvis du har brug for hjælp til Lowell ACR-SEQ4-1509 stil et spørgsmål nedenfor, og andre brugere vil svare dig




Ikke kategoriseret Lowell Manualer

Lowell

Lowell ACR-SEQ4-1509 Manual

11 December 2024
Lowell

Lowell ACS-2014-HW Manual

7 December 2024
Lowell

Lowell ACS-1510-RPC Manual

7 December 2024
Lowell

Lowell RPC-30 Manual

7 December 2024
Lowell

Lowell ACS-2012 Manual

7 December 2024
Lowell

Lowell ACS-2024-2C Manual

7 December 2024
Lowell

Lowell ACS-1524 Manual

7 December 2024
Lowell

Lowell ACS-1507 Manual

7 December 2024

Ikke kategoriseret Manualer

Nyeste Ikke kategoriseret Manualer