L2214-INS-LAB-RevD10
Features
1. Fast oral temperature measurement in approximately 10 seconds.
2. Very sensitive unit; best for quick oral and rectal measurement.
3. Easy to read digital LCD (Liquid Crystal Display).
4. Flexiblesofttiptsnaturallyundertongueorunderarm.Won’tpokeorhurt.Flexibleprobeconforms
todifferentmouths.
5. Compact, accurate and durable LSI (Large Scale Integration) unit.
6. Ifthethermometerisinadvertentlyleftonaftertemperaturestabilization,itwillautomaticallyshutoffin
about 10 minutes.
7. Small,lightweightunit.Universaluseforthewholefamily.
8. Lesshazardousthanmercuryglassthermometers.
9. Lowbatteryindicator:whenthesymbol ”appears,thebatteryneedstobereplaced.
10.Thisunitiswaterproof.
Parts Description
Specications
Range 90°F ~ 109.3°F (32.0°C ~ 42.9°C)
< 90.0°F (32.0°C) displays Lo°F (°C)
> 109.9°F (42.9°C) displays Hi°F (°C)
Resolution 0.1° F (°C)
Accuracy ±0.2°F(93.2°Fto107.6°F)±0.4°F(otherrange)
 ±0.1°C(34.0°Cto42.0°C)±0.2°C(otherrange)
Display LCD (Liquid Crystal Display) 3 ½ digits
Battery (included Micro alkaline battery 192.LR41.1 5.5V
PowerConsumption 0.15milliwattsinmeasurementmode
BatteryLife >200hourscontinuousoperation
Dimensions 5.28 in x .98 in x .47 in (134 mm x 25 mm x 12 mm)
Weight Approximately0.03lb(14g)includingbattery
Beeper Approximately8secondssoundsignalwhenpeaktemperatureisreached
Memory Built-in memory enables display of previously measured value
Operation Environment Temperature 50°F ~ 95°F (10°C ~ 35°C )
Humidity 30% ~ 75% RH
Storage Environment Temperature 13°F ~ 140°F (-25°C ~ 60°C )
GuaranteeofQuality CerticationISO13485
Conformity EN12470-3, EN60601-1
ProductClassication TypeBF equipment
Precautions — Care and Maintenance
1. Donotboiltheprobe.Cleanthethermometerbywipingitwithaclean,drycloth,anddisinfectthe
probewithisopropylalcohol.
2. Donotdropthethermometerorexposeittoheavyshock.Thethermometerisnotshockproof.
3. Donotbendorbitetheprobe.
4. Donotstorethethermometerindirectsunlight,hightemperature,highhumidity,orinadustyenviron-
ment. Performance may be degraded.
5. Stopusingthethermometerifitoperateserraticallyorifthedisplaymalfunctions.
6. Keepthermometeroutofthereachofchildrenandalwayssupervisechildrenduringmeasurement.
7. Cleanthethermometerprobebeforestoring.
8. Donotdisassemblethethermometerexcepttoreplacethebattery.
9. Ifthethermometerhasbeenstoredatbelow-freezingtemperatures,allowittowarmnaturallytoroom
temperature before use.
10.Thermometerperformancemaybedegradedifoperatedorstoredoutsiderecommendedtemperature
andhumidityrangesshowninSpecicationssectionabove,orifthepatient’stemperatureisbelow
ambient (room) temperature.
Battery Replacement
1. Whenthesymbol ”appears,thebatteryneedstobereplaced.
2. Pullthebatterycoveroffinthedirectionshownbelow.
3. Ifnecessary,useapointedobjectsuchasatoothpickorinsulated
probetogentlyprythebatterycoverandbatteryloose;avoidusing
asharpmetalobjectforthisoperation.
4. Placeanew1.55VDCbutton-sizebattery,type192.LR41or
equivalent,inthebatterychamberwithnegativeside(–)upand
positiveside(+)down.
5. Replaceandfastenthebatterycoversecurely.
Warning: Discard the old battery carefully, out of the reach of children. Swallowing the battery
could be harmful or fatal. If the battery is inadvertently swallowed, contact a hospital immedi-
ately to have it removed. Do not dispose of the battery in a re. It may explode.
Model L2214
Digital Thermometer
INSTRUCTIONS FOR USE
Please read carefully before using
How to Use the Thermometer
1. DepresstheON/OFFbutton.Thedisplaywillshow or .
2. ReleasetheON/OFFbutton.ThedisplaywillshowLo°F(Lo°C)with°F(°C)ashing.
2. Disinfecttheprobewithisopropylalcohol.Seeinstructionsbelowtoplacetheprobeinanappropriate
position (oral, axillary, or rectal).
3. Oncethedegreesign(°For°C)hasstoppedashing,usuallywithin15-30seconds,thecorrecttem-
peratureisshown.Thetemperatureshowingwillnotchangeafterthe°F(°C)hasstoppedashing.
4. Thethermometerwillautomaticallyturnoffinapproximately9minutes.However,toprolongbattery
life,itisbesttoturnthethermometeroffbypressingtheON/OFFbuttononcethetemperaturehas
been noted.
Special Features
NormalTemperatureAlarm:Whenthepeaktemperaturehasregisteredandisreadytoread,analarmwill
sound.The“NormalTemperature”alarm(10beeps)willsoundforapproximately8seconds.
FeverAlarm:Whenthepeaktemperaturehasregisteredhigherthan99.5°F(37.5°C),thefeveralarm
(approximately10secondsofquickbeeps)willsound.
AutomaticLastTemperatureRecall:WhentheON/OFFbuttonispressedtoactivatethethermometer,
display188.8willchangetoshowthelastmeasuredtemperaturevalue,thenreturnto“readytomeasure”
mode.
FahrenheitandCelsiusSwitchable:TheFahrenheitorCelsiusmodecanbeswitchedbypressingthe
ON/OFFbuttonwithintherst5seconds.
Note: Always disinfect the thermometer before use.
Note: In Step 2, if the room temperature is greater than 90.0°F (32.0°C), it will be displayed rather than
Lo°F (°C).
Note: In Step 3, you may put a sanitary plastic probe shield on the sensor tip to help prevent cross
infection and contamination. Use of the probe cover may result in a 0.2°F (0.1°C) difference from actual
temperature. Dispose of any used probe shield and store the thermometer in a safe place.
Reliable Methods to Measure Temperature
Measuring Body Temperature:Changeinbodytemperatureisoneofthemostimportantindicatorsof
illness.Itisimportantthataccuratetemperaturesbetaken.Eventhoughthedigitalthermometerisused
insimilarmannertotheglassthermometer,instructionsforuseofthisthermometermustbefollowed
closely,andthepersontakingthetemperaturemustunderstandbodytemperature.
Body Temperature:Apersons’sbodytemperatureisusuallyseveraltenthstoonefulldegreelowerin
themorningthaninthelateafternoon.Therefore,ifyourtemperatureinthemorningis97.9°F(36.6°C),it
couldbe98.4°F(36.9°C)ormoreinthelateafternoonandstillbenormal.Todeterminewhatyournormal
bodytemperatureis,youshouldtakeyourtemperaturebothintheearlymorningandlateafternoonover
severaldays.Childrenhavethesamenormaltemperaturerangeasadults.Afeverborbothchildrenand
adultsintypicallydenedasanoraltemperaturehigherthan99.5°F(37.5°C).Exercise,excessivecloth-
ing,hotbath,hotweather,andwarmfoodanddrinkcancausemildelevationsofupto100.4°F(38°C)
inoraltemperature.Ifyoususpectoneofthesetobethecauseofanelevatedreading,eliminatethe
possiblecauseandretakethetemperatureinhalfanhour.
Oral Use
Placetheprobewellunderthepatient’stongue.Instructthepatientto
keeptheirmouthclosedwhilethethermometerismeasuring.Anormal
oraltemperatureisusuallyconsideredtobebetween96.8°F–98.6°F
(36.0°C–37.5°C).
Rectal Use
Ifrectaltemperatureisrecommendedbyyourdoctor,youmayuseaprobecover.Insertthermometer
tipintotheprobecover.Lubricatetheprobecoverwithawatersolublejellyforeasierinsertion.Donot
usepetroleumjelly.Inserttipofprobenomorethan½inchintorectum.Stopifyoumeetanyresistance.
Thesensingdeviceisontheverytipoftheprobeandthereisnoneedtoinserttheprobedeepinto
therectum.Rectaltemperatureisusuallyapproximately1.0°F–2.0°F(0.5°C–1.0°C)higherthanoral
temperature.
Axillary Use (Armpit)
Wipearmpitwithadrytowel.Placeprobeinthepatient’sarmpitandkeepthepatient’sarmpressedrmly
againsttheirside.Axillarytemperatureisusuallyapproximately1.0°F–2.0°F(0.5°C–1.0°C)lowerthan
oraltemperature.Note:Inordertoachievebetteraxillarytemperaturemeasurementresult,aminimum
measuringtimeof3-5minutesisrecommendedregardlessofthebeepsound.
Note: Children should be attended by an adult during the entire temperature recording process. After
use, the digital thermometer should be stored in a safe place, out of the reach of children. If you compare
temperatures between two thermometers, it is possible to have two different readings, even if both
thermometers are within their accuracy tolerances. Differences in how you take each reading and the
thermometer’s tolerance range can account for nearly 0.2°F (0.1°C) variability.
Remember: Find your normal temperature and watch for changes.
Cleaning Instructions
Tocleanthethermometer,washthetipwithasolutionofmilddetergentandcoolwater.Todisinfectthe
thermometer,wipethesensorandlowerstemwithacleanclothdippedinisopropylalcohol.
Limited warranty
Thisthermometerisguaranteedagainstmanufacturer’sdefectsundernormalhouseholduseforoneyear
fromthedateofpurchase.Followingtheinstructionscloselywillensureyearsofdependableoperation.
Ifthethermometerdoesnotfunctionproperly,rstcheckthebatteryandreplaceitifnecessary(see
instructionsabove).RepairDepartment:1-800-672-8293.
ManufacturedforGFHealthProducts,Inc.
Atlanta, Georgia 30360
©2010GFHealthProducts,Inc.
MadeinChina
www.grahameld.com


Produkt Specifikationer

Mærke: Lumiscope
Kategori: Termometre
Model: L2214

Har du brug for hjælp?

Hvis du har brug for hjælp til Lumiscope L2214 stil et spørgsmål nedenfor, og andre brugere vil svare dig