Mabis Jumbo Display Manual

Mabis Termometer Jumbo Display

Læs nedenfor 📖 manual på dansk for Mabis Jumbo Display (2 sider) i kategorien Termometer. Denne guide var nyttig for 28 personer og blev bedømt med 4.5 stjerner i gennemsnit af 2 brugere

Side 1/2
Specifications
DISPLAY: Liquid Crystal Display
DISPLAY RESOLUTION: 4 Digits (1/10TH of a degree increments)
MEASUREMENT RANGE: 89.6oF to 109.2oF
ACCURACY: ±0.2oF between 93.2oF and 107.6oF
SELF-TEST: All segment display test of 188.8
o
F
Meach cycle
TONE: Thermometer beeps when activated and produces a series of tone signals when the
temperature increase is less than 0.2
oF/16 seconds
MEMORY: Displays last measured temperature
BATTERY: One, LR41 Alkaline
BATTERY LIFE: Approximately 3,000 temperatures
AUTOMATIC SHUT-OFF: After approximately 10 minutes
STORAGE TEMPERATURE: 14oF to 140oF
HUMIDITY: 10% to 80% RH
DIMENSIONS: 5-1/2” x 13/16” x 3/8”
WEIGHT: 0.5 Ounces (14.0 grams)
Specifications are subject to change without notice.
General Care
1. The thermometer should only be used under the supervision of an adult.
2. Do not walk, run or talk during temperature taking.
3. Clean the thermometer before and after each use.
4. Store the unit in the protective case when not in use.
5. Do not bite the probe.
6. Do not store the unit where it will be exposed to direct sunlight, dust or humidity.
Avoid extreme temperatures.
7. Dropping or subjecting your thermometer to strong shocks should be avoided.
8. Do not attempt to disassemble the unit, except to replace the battery.
9. If ERR displays and measurement is not attainable, the unit must be replaced.
NOTE: Performance of the device may be degraded if: operated outside of stated
temperature and humidity range; stored outside of stated temperature and humidity
range; thermometer undergoes mechanical shock (drop); patient temperature is
below ambient temperature.
Changing the Battery
The battery in your digital thermometer needs to be replaced when the
t
” symbol
appears in the lower right of the display. Replace the battery with a 1.55V, LR41
alkaline or SR41 silver oxide type or equivalent.
To replace the battery,
1. Slide the battery cap away from the unit.
2. Using a non-metal pointed tool, carefully remove the
battery and insert the new battery with the positive
(+) side facing the display side of the unit.
3. Carefully slide the battery cap back into place, making sure that the cap fits
snugly to protect the battery compartment from moisture.
Note: Please properly dispose the battery away from small children and heat.
Taking an Oral Temperature
Approximate measurement time:
60 seconds
1. Using the diagram on the right, place
the probe tip under the tongue as near
as possible to the heat pocket. The
diagram also shows the temperature
variables by not placing the tip in the
heat pocket area.
Note: Drinking hot or cold fluids,
exercising, smoking or performing other
activities may raise or lower your
temperature. Therefore, it is important to
relax for approximately 5 minutes with your
mouth closed prior to taking a reading
2. The current temperature is shown and the oF will continue to flash during the
reading.
3. When the peak temperature has been reached, the
oF will stop flashing and the
thermometer will sound ten quick beeps.
4. To turn the unit off, press the ON/OFF button. The unit will automatically shut off
after approximately ten minutes.
Note: The mouth must remain closed during the measurement for the most accu-
rate reading. Opening the mouth could result in an extended measurement time
and may affect the reading.
Cleaning Instructions
Before and after each use, clean the area that extends about 2” from the tip of the
thermometer with a soft cloth and ispropyl alcohol diluted with water, or wash with
COLD soapy water.
NOTE:
1. The use of any other solution or cleaning method beyond the above mentioned
may result in reliability problems with the thermometer..
2. Do not let water or any solution penetrate the thermometer’s display window,
battery cover or back cover.
Ho to w Take Your Temperature
1. Clean and disinfect the thermometer according the instructions provided.
2. Apply a disposable probe cover to the clean, dry thermometer.
3. Determine whether the measurement site will be oral, rectal or underarm.
Note: Measurement time may vary based on the selected site.
4. Press the ON/OFF button (the unit will beep) to activate the thermometer.
This is the LCD display test, which insures all parts of the
display are functioning properly. Continue to hold the button
down and in approximately 3 seconds the display will show the
last recorded temperature as follows.
This display shows the last temperature reading. Within
approximately 3 seconds of releasing the button or if no
reading is stored in memory, the display will read as follows.
The L with the flashing oF indicates the thermometer is ready
to take a temperature reading.
PROBE COVER ORDER FORM
CUT OUT AND MAIL TO:
MABIS HEALTHCARE
1931 NORMAN DRIVE SOUTH
WAUKEGAN, IL 60085
Please send packages of disposable probe covers (100
probes per package). Enclosed is $5.00 per package plus $3.00 for
shipping and handling for each order.
Please ship to:
NAME:
ADDRESS:
CITY: STATE: ZIP:
PHONE:
CUT OUT AND MAIL TO:
MABIS HEALTHCARE
1931 NORMAN DRIVE SOUTH
WAUKEGAN, IL 60085
THERMOMETER WARRANTY REGISTRATION
(MUST BE COMPLETED WITHIN 10 DAYS OF PURCHASE)
NAME:
ADDRESS:
CITY: STATE: ZIP:
PURCHASED FROM:
CITY: STATE: ZIP:
DATE PURCHASED:
MODEL PURCHASED:
q15-720-000
USER INFORMATION (OPTIONAL)
q qMALE FEMALE AGE:
AGE OF YOUNGEST FAMILY MEMBER
q qUNDER 6 MONTHS 6 MONTHS - 1 YEAR
q q q1 - 3 YEARS 3 - 5 YEARS OLDER
PROBE TIP DIGITAL DISPLAY WINDOW ON/OFF BUTTON
BATTERY COVER
F
HEAT
POCKET
HEAT
POCKET
98.4oF
36.9oC
98.4oF
36.9oC
98.8 o
F
37.1 o
C
98.8
oF
37.1
oC
97.9oF
36.6oC
97.7oF
36.4oC
97.9oF
36.6oC
98.1oF
36.7oC
#91-1905-720 07/06
©2006 MABIS Healthcare
NOTE: This order form is for shipments within the United States and Canada.
LIMITED ONE YEAR WARRANTY
This MABIS Digital Thermometer is guaranteed to be free of manufacturing defects
for a period of one year from the date of purchase under normal use. This warranty
applies to the original registered purchaser only. All repairs on your MABIS Digital
Thermometer should be sent prepaid to: MABIS Healthcare, Attn: Repair
Department, 1931 Norman Drive South, Waukegan, IL 60085. MABIS Healthcare
shall incur no liability under this warranty for any damage from any cause other than
inherent manufacturing defects. ALL IMPLIED WARRANTIES, INCLUDING
MERCHANTABILITY AND FITNES S ARE LIMITED TO THE DURATION OF THIS
WARRANTY. THIS WARRANTY DOES NOT INCLUDE ANY LIABILITY
FOR INCIDENTAL
OR CONSEQUENTIAL DAMAGES. Some states do not allow limitation on how long
an implied warranty lasts or do not allow the exclusion or limitation of incidental or
consequential damages, so the above limitations or exclusions may not apply to
you. This warranty gives you specific legal rights and you may also have other rights
which vary from state to state.
Deluxe Jumbo Display”
Digital Thermometer
with Beeper and Memory
Thank you for purchasing a MABIS Digital Thermometer. Please read the following
instructions to achieve the most accurate temperatures and safe operation. With
proper care and use, your thermometer will provide you with years of reliable
readings.
What is a “Normal” Temperature?
Although the generally accepted “normal” temperature reading is 98.6
oF, tempera-
ture readings can vary from 97oF to 99oF and still may be considered “normal”.
Variations in temperature can be attributed to activities such as exercise, smoking,
eating and drinking. Even time of day may influence your temperature. For exam-
ple, your temperature is lower in the morning than in the afternoon. Other varia-
tions may be due to the location of the temperature reading. While the oral temper-
ature follows the guidelines previously described, a rectal temperature is generally
1.0oF . higher Conversely, an axillary (under the arm) temperature will be 1.0
oF
lower.
Features of your MABIS Digital Thermometer
Taking an Axillary Temperature (under the arm)
Approximate measurement time: 5 minutes or longer
1. Wipe the underarm with a dry towel.
2. Place the probe tip under the arm so the tip is touching the skin with the ther-
mometer perpendicular to the body.
3. Position the arm across the chest so the probe tip is well covered by the arm.
This also insures the probe is not affected by the room’s air.
4. When the peak temperature has been reached, the
oF will stop flashing and the
thermometer will sound ten quick beeps.
5. To turn the unit off, press the ON/OFF button. The unit will automatically shut off
after approximately ten minutes.
Note: Axillary temperatures are generally 1.0
oF lower than oral readings.
Taking a Rectal Temperature
Approximate measurement time: 60 seconds
Note: Rectal temperatures are an appropriate and reliable method for infants and
small children. this method should only be used when it is impossible orOtherwise,
impractical to take an oral or axillary temperature.
1. After applying the disposable probe cover, apply a water-soluble lubricant to
the tip.
2. Gently insert the probe a MAXIMUM of 1/2” into the rectum.
3. When the peak temperature has been reached, the
oF will stop flashing and the
thermometer will sound ten quick beeps.
4. To turn the unit off, press the ON/OFF button. The unit will automatically power
down after approximately ten minutes.
Note: Rectal temperatures are generally 1.0
oF higher than oral readings.
Using Disposable Probe Covers
It is recommended to use the enclosed disposable probe covers to prevent cross
contamination. Additional probe covers can be purchased from your MABIS Dealer
or with the order form provided.
#91-1905-720 07/06


Produkt Specifikationer

Mærke: Mabis
Kategori: Termometer
Model: Jumbo Display

Har du brug for hjælp?

Hvis du har brug for hjælp til Mabis Jumbo Display stil et spørgsmål nedenfor, og andre brugere vil svare dig




Termometer Mabis Manualer

Termometer Manualer

Nyeste Termometer Manualer

TFA

TFA 12.1004 Manual

21 December 2024
Owon

Owon TI219 Manual

21 December 2024
TFA

TFA 30.1000 Manual

17 December 2024
TFA

TFA 14.1503 Manual

17 December 2024
TFA

TFA 15.2010 Manual

17 December 2024
TFA

TFA 30.3053.IT Manual

16 December 2024
Optex

Optex PT-7LD Manual

16 December 2024
Optex

Optex PT-U80 Manual

16 December 2024
Ebro

Ebro TFI 260 Manual

15 December 2024