Copyright © 2013 Maretron, LLP All Rights Reserved P/N: M003036 Rev. 1.0 1/13
Installation Instructions
TFT-5H SAE 5-Bolt Pattern Non-Displacement Hull Focus Tube
TFT-1.5NPT 1.5” NPT Non-Displacement Hull Focus Tube
TFT-1.25BSP 1.25” BSP Non-Displacement Hull Focus Tube
Packing List
Please find the following items included:
1 adapter with focus tube
1 focus tube cap with center hole
1 packet of epoxy
1 wooden mixing stick
Installation on a Tank with a SAE J1810 5-Bolt Fitting and Focus Tube
If a focus tube is used for a tank with sensor mounting hole and use a saw a SAE J1810 5-bolt fitting, determine the depth of the tank at the location of the tank
with a metal-cutting blade to trim the focus tube so that it reaches 1” (2.54cm) above the tank bottom when mounted. Remove any burrs from the end of the focus
tube after trimming. Optionally, install the focus tube cap (see below).
Next, place the gasket included with the focus tube over the focus tube (between the focus tube flange and the tank mounting flange), and then drop the focus
tube into the hole so that the bolt holes on the focus tube, focus tube gasket, and tank fitting all line up (WARNING – the gasket must be properly aligned; it only
fits one way).
Place the gasket included with the TLM100/TLM150 over the focus tube so that the bolt holes line up (WARNING – the gasket must be properly aligned; it only fits
one way), then place the TLM100/TLM150 sensor component on top of the TLM100/TLM150 gasket so that the bolt holes line up.
Insert mounting screws into the bolt holes on the TLM100/TLM150 sensor component, and thread them into the tank fitting (the tank fitting may instead have studs
installed, so in this case, install the nuts over the studs), tightening them to a torque of 10-15 in-lbs (1.1-1.7 N·m). Do not use threadlocking compounds containing
methacrylate ester, such as Loctite Red (271), as they will cause stress cracking of the plastic enclosure.
1” (2.54cm) clearance
between focus tube
and tank bottom
TLM100/TLM150 Interface
Component
Threaded Tank Fitting
Threaded Focus Tube
TLM100/TLM150 Gasket
TLM100/TLM150 Sensor
Component
Mounting Screws (x5)
TLM100/TLM150 Interface
Component
1” (2.54cm) clearance
between focus tube
and tank bottom
SAE 5-Bolt Tank
Fitting
Focus Tube Gasket
Focus Tube
TLM100/TLM150 Sensor
Component
TLM100/TLM150 Gasket
Mounting Screws (x5)
Installation on a Tank with a 1.25”BSP or 1.5”NPT Threaded Tank Fitting and Focus Tube
Figure 1 – Mounting TLM100/TLM150 to SAE 5-Hole Tank with
Focus Tube
Figure 2 – Mounting TLM100/TLM150 with Focus Tube on Threaded Tank
Fitting
If a focus tube is used for a tank with sensor mounting hole and use a saw a SAE J1810 5-bolt fitting, determine the depth of the tank at the location of the tank
with a metal-cutting blade to trim the focus tube so that it reaches 1” above the tank bottom when mounted. Remove any burrs from the end of the focus tube after
trimming. Optionally, install the focus tube cap (see below).
For a threaded tank sender mounting hole, first thread the adapter into the tank opening and tighten to a torque of 3-5 ft-lbs (4.1-6.8 N·m).


Produkt Specifikationer

Mærke: Maretron
Kategori: Ikke kategoriseret
Model: TLM150

Har du brug for hjælp?

Hvis du har brug for hjælp til Maretron TLM150 stil et spørgsmål nedenfor, og andre brugere vil svare dig




Ikke kategoriseret Maretron Manualer

Maretron

Maretron TLM150 Manual

15 August 2024

Ikke kategoriseret Manualer

Nyeste Ikke kategoriseret Manualer