DUSK TILL DAWN LAMP TIMER
SWITCHING MODES
i) Timer mode ii) Random mode iii) On mode iv) Off mode v) Dusk ‘Til’ Dawn mode
i). Timer Mode
The timer will turn on and off for a pre-set time period or until the light rises above the setting of the sensor.
1). Set the RANDOM switch to the OFF postition.
2). Set the MODE switch for the required time period - 0.5, 1, 2, 4, 6 or 8 hours.
ii). Random Mode
1). Set the RANDOM switch to the ON postition.
2). Set the MODE switch for the required time period.
iii) On Mode (Manual ‘ON’ switch) Set the MODE to the ON position. The timer is now permanently on.
iv) Off Mode (Manual ‘OFF’ switch) Set the MODE switch to the OFF position.The timer is now permanently off.
v) Dusk ‘Til’ Dawn mode The timer switches on at dusk and off at dawn depending on the setting of the Sensitivity regulator.
1. Set the MODE switch to the DUSK TO DAWN position. The timer will switch on and off randomly for a pre-set time period or until the light level
increases above the setting of the sensor.
SENSITIVITY REGULATOR
The light level at which the timer switches on or off can be adjusted by means of the Sensitivity regulator. To set the light level to turn the timer off:
1. Set the MODE switch to the DUSK TO DAWN position.
2. Turn the Sensitivity regulator clockwise to turn on/off at higher light levels, or anti-clockwise for lower light levels.
IMPORTANT
The timer should be removed from the socket before setting the time interval for all modes. The count down time will be reset to the preset time when the light
level rises above the setting of the sensor. The timer can be reset by disconnection of the power for at least 15 seconds.
POWER INDICATOR
The power indicator will light when there is power to the timer socket.
POSITIONING OF THE TIMER
The Dusk ‘Til’ Dawn Timer should be in a socket that is exposed to direct daylight. Ensure that the sensor is not activated by external or internal lighting.
FEATURES
This Masterplug Dusk 'Til’ Dawn Timer is ideal for home security. It is easy to use with multiple functions.
TIMER MODE - The timer will turn on at dusk and remain on for the pre-set time or until the light level rises above the setting of the sensor.
RANDOM MODE-The timer will switch on and off randomly for a pre-set time period or until the light level increases above the setting of the sensor.
DUSK TO DAWN-The timer switches on at dusk and off at dawn MANUAL OVERRIDE-lnstant ON/OFF operation
TECHNICAL DATA
Power Source: 220-240 Volts AC, 50Hz. Maximum Resistive load: 10 Amps, 2,300 Watts. Maximum Inductive load: 3 Amps, 720 Watts.
Maximum Incandescent lamp load: 3 Amps, 720 Watts. Operating Temperature: 0 C- 35 C.
SAFETY WARNING:
Please read carefully and use in accordance with our safety instructions below.
DO Position the unit carefully to avoid accidents.
DO Keep children away from sockets and electrical appliances.
DON’T Open the unit - there are no user servicable parts inside.
DON’T Use outdoors or in damp conditions.
DON’T Exceed the maximum load: Inductive -3 Amps, 720 WATT - i.e. Fluorescent lamps. Resistive - 10 Amps, 2,300 WATT - i.e. Portable Hi-Fi/
Radio,Heaters, etc. Incandescent lamp - 3 Amps, 720 WATT - i.e. Table/Floor lamps using conventional (not energy saving) bulbs.
LUX
1
0.5
DUSK
TO
DAWN
ON
ON
RANDOM
OFFOFF
2
4
6
8
+
-
Light Sensor
Sensitivity Regulator
Random Switch
Mode/Time Switch
Power Indicator
Produkt Specifikationer
Mærke: | Masterplug |
Kategori: | Tidsskifte |
Model: | DUSK TILL DAWN LAMP TIMER |
Har du brug for hjælp?
Hvis du har brug for hjælp til Masterplug DUSK TILL DAWN LAMP TIMER stil et spørgsmål nedenfor, og andre brugere vil svare dig
Tidsskifte Masterplug Manualer
21 August 2024
Tidsskifte Manualer
- Tidsskifte GE
- Tidsskifte Hager
- Tidsskifte Finder
- Tidsskifte Theben
- Tidsskifte Quigg
- Tidsskifte Vivanco
- Tidsskifte Grässlin
- Tidsskifte Goobay
- Tidsskifte Gamma
- Tidsskifte Alecto
- Tidsskifte Ansmann
- Tidsskifte Tork
- Tidsskifte Basetech
- Tidsskifte Bachmann
- Tidsskifte Perel
- Tidsskifte Paladin
- Tidsskifte Brennenstuhl
- Tidsskifte GAO
- Tidsskifte Renkforce
- Tidsskifte Orbis
- Tidsskifte Noma
- Tidsskifte Profile
- Tidsskifte Intermatic
- Tidsskifte Tevion
- Tidsskifte Blokker
- Tidsskifte Sygonix
- Tidsskifte Plieger
- Tidsskifte UPM
- Tidsskifte Duro
- Tidsskifte Xavax
- Tidsskifte Gira
- Tidsskifte Praxis
- Tidsskifte Go Green
- Tidsskifte Handson
- Tidsskifte Elro-Flamingo
- Tidsskifte Suevia
- Tidsskifte Unitec
- Tidsskifte Muller
- Tidsskifte Paget
- Tidsskifte Moeller
- Tidsskifte Eltrav
- Tidsskifte PCF360
- Tidsskifte Wit
- Tidsskifte Pollin
- Tidsskifte Obi
- Tidsskifte Kinel
- Tidsskifte Masterclear
- Tidsskifte PROmax
- Tidsskifte Wachsmuth - Krogmann
- Tidsskifte TimeControl
Nyeste Tidsskifte Manualer
23 September 2024
17 September 2024
27 August 2024
27 August 2024
26 August 2024
26 August 2024
26 August 2024
26 August 2024
26 August 2024
26 August 2024