Side 1/4
2700-951
Touch Free Dispensing System Instructions
Please carefully read all instructions before installing and using the dispenser.
Installing the Dispenser Do not install in locations where dispenser may be exposed to wet environments, such as showers or areas where walls are washed down.
Press dispenser firmly onto
mounting surface by
applying pressure to the
inside of backplate for 15
seconds.
Do not load refill
for at least 24 hours.
Tape Installation
Use only on smooth, dry surfaces
Install dispenser
at least 6” above
counter top.
Clean
installation
surface with
supplied prep
pad. Allow
surface to dry for
60 seconds.
Open dispenser
by pushing
release on bottom
of dispenser.
Peel paper off of
installation tape
located on back
of dispenser.
Fastener Installation
Use on rough or smooth surfaces
Install dispenser
at least 6” above
counter top.
Open dispenser
by pushing
release on
bottom of
dispenser.
Peel paper off of
installation tape,
line up screws
with anchors,
and press firmly
into position.
Using
backplate as
template, mark
and drill 4 center
holes using 1/4”
spiral masonry
drill or 1/4” wood
drill. If required,
pierce installation
tape at installation
holes. Make sure
tape backing
remains in place.
Install #10 x 1”
anchors into
the 4 drilled
holes.
Insert Type A
#10 x 1” screws
into installation
holes in backplate
and through
installation tape.
Tighten screws
securely,
being careful
not to over-
tighten.
Battery Installation
Close dispenser
cover. Status
light will blink
green after
closing,
indicating that
batteries are
correctly
installed and
dispenser is
ready to accept
refills.
Open
dispenser
by pushing
release on
bottom of
dispenser.
Remove two
screws
securing
battery box
cover using
Philips
screwdriver.
Use 3 high-
quality C-cell
alkaline
batteries. Do not
mix old and
new batteries.
Replace
battery box
cover, being
careful not to
over-tighten
screws.
Cleaning and Maintenance
Clean exterior surfaces of the dispenser using
warm water and mild soap.
DO NOT USE ABRASIVE CLEANERS.
Dry with a soft cloth
Loading Refill into the Dispenser
Open
dispenser
by pushing
release on
bottom of
dispenser.
Check that the
color of refill
collar key
matches color
key located
immediately
below status
light.
Insert refill
at slight
angle into
dispenser
so nozzle is
inside lock
release.
Fully insert refill down
into lock release until
refill clicks into place.
Close dispenser. Prime
refill pump by placing
hands below dispenser
until product is
dispensed. (See
Dispenser Use below)
To remove
refill, press
lock release
and lift refill
up and out of
dispenser.
Dispenser Use
1. Place palms approximately 2” below dispenser.
2. Product will be dispensed within 1 second of
sensor activation.
3. To receive additional product, remove hands
from below dispenser and repeat Step 1.
Troubleshooting
No Dispense, Motor Does Not Run
• Hands are not directly beneath sensor
• No refill is loaded
• Incorrect refill is loaded
• Batteries are not loaded, or are loaded incorrectly
No Dispense, Motor Runs
• Refill is empty or is loaded improperly
• Refill pump is not primed
Produkt Specifikationer
Mærke: | Micrell |
Kategori: | Zeepdispenser |
Model: | TFX |
Har du brug for hjælp?
Hvis du har brug for hjælp til Micrell TFX stil et spørgsmål nedenfor, og andre brugere vil svare dig
Zeepdispenser Micrell Manualer
21 August 2024
Zeepdispenser Manualer
- Zeepdispenser Ikea
- Zeepdispenser SilverCrest
- Zeepdispenser Emerio
- Zeepdispenser Hansgrohe
- Zeepdispenser Smeg
- Zeepdispenser Miomare
- Zeepdispenser Tiger
- Zeepdispenser Homedics
- Zeepdispenser Tork
- Zeepdispenser Arendo
- Zeepdispenser DCG
- Zeepdispenser Delta
- Zeepdispenser Purell
- Zeepdispenser San Jamar
- Zeepdispenser GOJO
Nyeste Zeepdispenser Manualer
18 December 2024
6 September 2024
6 September 2024
6 September 2024
3 September 2024
3 September 2024
3 September 2024
3 September 2024
1 September 2024
30 August 2024