1. Determine hole positions according to left and right
side of the installation plate. The hole center is obtained
by measuring the distance as shown in the diagram above.
2. Dirll the piping plate hole with 65mm hole-core drill.
3. Drill the piping hole at either the right or the left and the
hole should be slightly slanted to the outdoor side.
4. Always take steps to protect the pipe when drilling metal
grid,metal plate or the like.
INSTALLATION MANUAL FOR
ROOM AIR CONDITIONER
(Split Wall-Mounted Type)
DRILL A HOLE IN THE WALL
INSTALLATION PLATE MOUNTING
2
1
I
N
D
O
O
R
U
N
I
T
Please read these safety precautions carefully before installation
Be sure to follow all the precautions below, they are all important for ensuring safety.
This symbol indicates the possibility of death or serious injury.
This symbol indicates the possibility of injury or damage to property.
1) This equipment must be grounded and installed with ground leakage current breaker. It may cause
electrical shock if grounding is not perfect.
2) Do not install the unit at place where leakage of flammable gas may occur. In case gas leaks and
accumulates at surrounding of the unit, it may cause fire.
3) Carry out drainage piping as mentioned in installation instructions. If drainage is not perfect, water
may enter the room and damage the furniture.
1) Install according to this installation instructions strictly. If installation is defective, it will cause water
leakage, electrical shock,or fire.
2) Use the included accessories parts and specified parts for installation. otherwise, it will cause the set
to fall, water leakage, electrical shock,or fire.
3) Install at a strong and firm location which is able to withstand the set s weight. If the strength is not
enough or installation is not properly done, the set will drop and cause injury.
4) For electrical work, follow the local national wiring standard, regulation and this installation instructions.
An independent circuit and single outlet must be used. If electrical circuit capacity is not enough or
defect found in electrical work, it will cause electrical shock,or fire.
5) Use the specified cable and connect tightly and clamp the cable so that no external force will be acted
on the terminal. If connection or fixing is not perfect, it will cause heat-up or fire at the connection.
6) Wiring routing must be properly arranged so that control board cover is fixed properly. If control board
cover is not fixed perfectly, it will overheat at connection point of terminal, fire or electrical shock.
7) When carrying out piping connection, take care not to let air substances other than the specified
refrigerant go into refrigeration cycle. Otherwise, it will cause lower capacity,abnormal high pressure
in the refrigeration cycle, explosion and injury.
8) Do not modify the length of the power supply cord or use of extension cord, and do not share the
single outlet with other electrical appliances. Otherwise, it will cause fire or electrical shock.
SAFETY PRECAUTIONS
CAUTION
WARNING
CAUTION
WARNING
Please read this installation manual carefully before operating the unit to ensure correct installation.
If the power cord is damaged, replacement work shall be performed by authorised personnel only.
Installation work must be performed in accordance with the national wiring standards by authorised
personnel only.
Contact an authorized service technician for repair, maintenance and installation of this unit.
This appliance is not intended for use by persons(including children) with reduced physical, sensory
or mental capabilities, or lack of experience and knowledge, unless they have been given supervision
or instruction concerning use of the appliance by persons responsible for their safety.
Children should be supervised to ensure that they do not play with the appliance.
All the pictures in the instructions are for explanation purposes only. The actual shape should prevail.
The design and specifications are subject to change without prior notice for product improvement.
Consult with the sales agency or manufacturer for details.
There should not be any heat source or stream
near the unit.
There should not be any obstacles blocking the
air circulation.
A place where air circulation in the room is good.
A place where drainage can be easily done.
A place where noise prevention is taken into
consideration.
Do not install the unit near the door way.
Ensure the spaces indicated by arrows from the
wall,ceiling,fence or other obstacles.
There should not be any direct sunlight. If unavoidable,
sunlight prevention should be taken into consideration.
Outdoor unit dimension
mm(WxHxD)
A(mm) B(mm)
530 290
560
549
640
335
325
404
481
549
276
276
Mounting dimensions
670x540x265
780x540x250
760x590x285
845x700x320
810x558x310
940x810x375
Indoor unit
Outdoor unit
If an awning is built over the unit to prevent
direct sunsight or rain,be careful that heat
radiation from the condenser is not obstructed.
There should not be any animal or plant which
could be affected by hot air discharged.
Keep the spaces indicated by arrow from wall
ceiling, fence or other obstacles.
Do not place any obstacles which may cause
a short circuit of the discharged air.
Anchor the outdoor unit with a bolt and nut 10 or
8 tightly and horizontally on a concrete or rigid mount.
Settlement of outdoor unit
NOTE: The outdoor unit you purchase may be like one
of the following. Install the outdoor unit according to the
dimension as indicated in the table below:
A
W
B
D
Air inlet
Air outlet
Air inlet
INSTALLATION PRECAUTIONS
CONNECT THE CABLE TO THE INDOOR UNIT
3
,
Terminal block of indoor unit
Connect the cable to the indoor unit
Before performing any electrical work, turn off the main power to the system.
1. The inside and outside connecting cable can be connected without removing the front grille.
2. The indoor power cord type is H05VV-F or H05V2V2-F, the outdoor power cord and
interconnected cord type is H07RN-F.
3. Lift the indoor unit panel up, remove the electrical box cover by loosening the screw.
4. Ensure the colour of wires of outdoor unit and the terminal Nos. are the same to the indoor s
respectively.
5. Wrap those cables not connected with terminals with insulation tapes, so that they will not touch
any electrical components. Secure the cable onto the control board with the cord clamp.
NOTE:
Electronic box
cover
Front Panel
To outdoor unit
Model A Model B
To outdoor unit
L(1)
2(N)
S
1
W
2(N)
S
1(L)
1
2
3
4
5
7
8
9
10
6
Installation Plate
Clip Anchor
Self-tapping Screw A ST3.9x25
Seal(For cooling & heating models only)
Drain Joint(For cooling & heating models only
Connecting
pipe
Assembly
Liquid side
Gas side
Remote controller
Self-tapping Screw B ST2.9x10
6.35
9.52
9.52
12.7
16
Parts you must purchase. The pipe
size differ from appliance to appliance.
Consult the technician for the proper
size.
1
5-8(depending on models)
5-8(depending on models)
1
1
1
2
1
1
Except the above parts provided,the other parts needed during installation you must
purchase.
Remote controller holder
ACCESSORIES
Number
Name of Accessories Qty
NOTE:
optional
parts
SELECT THE BEST LOCATION
NOTE: If used as MONO unit, for the standby control needs, the cross section area of cable connected
to L(1)/W, 1/1(L), 2(N) must be sufficient for the maximum system current. The maximum system current
is equal to the sum of indoor unit and outdoor unit rated current. If used as MULTI unit, L(1)/W on the
terminal block does not need to be connected.
4
CONNECTIVE PIPE AND DRAINAGE INSTALLATION
1. Run the drain hose sloping downward.
Do not install the drain hose as illustrated
in wrong figures.
2. When connecting extension drain hose,
insulate the connecting part of extension
drain hose with a shield pipe, do not let
the drain hose slack.
Drainage
Right Wrong
Correct orientation
of Installation Plate
1. Fit the installation plate horizontally on
structural parts of the wall withspaces
around the installation plate.
2. If the wall is made of brick, concrete
or the like, drill five or eight 5mm
diameter holes in the wall. Insert
clip anchor for appropriate mounting
screws.
3. Fit the installation plate on the wall
with five or eight type A screws.
Mount the Installation Plate and drill
holes in the wall according to the wall
structure and corresponding mounting
points on the installation plate. The
installation plate providedwith the
machine differ from appliance
to appliance.(Dimensions are in
mm unless otherwise stated)
NOTE:
NOTE:
"
"
Installation Plate Mounting
The mounting wall is strong and solid enough
to prevent it from the vibration.
45
45
280
120mm or
more to wall
120mm or
more to wall
120mm or
more to wall
150mm or more to ceiling
150mm or more to ceiling
Left rear side
refrigerant
pipe hole 65
36.5
835
140 110
Left rear side
refrigerant
pipe hole 65
Right rear side
refrigerant
pipe hole 65
Right rear side
refrigerant
pipe hole 65
Indoor unit outline
Indoor unit outline
120mm or
more to wall 120mm or
more to wall
Indoor unit outline
990
315
135
260
150mm or more to ceiling
Left rear side
refrigerant
pipe hole 65 Right rear side
refrigerant pipe
hole 65
Model C
Model B
Model A
120mm or
more to wall
45
45
36.5
750
180 110
280
202000192486 CS159I1-BP11M(L) 20140515
Air freshening filter(used to install on Air filter)
Electric safety regulations for the initial Installation
1. If there is serious safety problem about the power supply, the technicians should refuse to install
the air conditioner and explain to the client until the problem is solved.
2. Power voltage should be in the range of 90%~110%of rated voltage.
3. The surge protector and main power switch with a 1.5 times capacity of Max. Current of the unit should
be installed in power circuit. Ensure the air conditioner is grounded well.
4. The appliance shall be installed in accordance with national wiring regulations. Do not operate your air
conditioner in a wet room such as a bathroom or laundry room.
5. An all-pole disconnection device which has at least 3mm clearances in all poles, and have a leakage
current that may exceed 10mA, the residual current device(RCD) having a rated residual operating
current not exceeding 30mA, and disconnection must be incorporated in the fixed wiring in accordance
with the wiring rules.
6. For the unit adopts auxiliary electric heater, keep at least 1 meter away from the nearest combustible
materials.
7. According to the attached Electrical Connection Diagram located on the panel of the indoor & outdoor
unit to connect the wire.
8. All wiring must comply with local and national electrical codes and be installed by qualified and
skilled electricians.
9. An individual branch circuit and single receptacle used only for this air conditioner must be
available. See the following table for suggested wire sizes and fuse specifications:
Minimum cross-sectional area of conductors:
Rated curr ent
of appliance
(A)
>3 and 6
>6 and 10
>10 and 16
>16 and 25
>25 and 32
>32 and 40
Nominal cross-sectional
area
(mm2)
0.75
1
1.5
2.5
4
6
Electrical work
The wire size of power supply cord and
interconnected wire and the current of
the fuse or switch are determined by the
maximum current indicated on the
nameplate which located on the side
panel of the unit. Please refer to the
nameplate before selecting the wire size,
fuse or switch.
The controller of the air conditioner
designed with a fuse protection function
under abnormal conditions, the
specifications of the fuse have printed on
the circuit board, such as: T3.15A/250VAC,
T5A/250VAC, etc.
NOTE:
Produkt Specifikationer
Mærke: | Midea |
Kategori: | Klimaanlæg |
Model: | Oasis MSOW |
Har du brug for hjælp?
Hvis du har brug for hjælp til Midea Oasis MSOW stil et spørgsmål nedenfor, og andre brugere vil svare dig
Klimaanlæg Midea Manualer
5 December 2024
5 December 2024
5 December 2024
5 December 2024
5 December 2024
5 December 2024
5 December 2024
5 December 2024
5 December 2024
4 December 2024
Klimaanlæg Manualer
- Klimaanlæg DeLonghi
- Klimaanlæg Bosch
- Klimaanlæg Sencor
- Klimaanlæg TCL
- Klimaanlæg Zibro
- Klimaanlæg Siemens
- Klimaanlæg Day
- Klimaanlæg Samsung
- Klimaanlæg Wilfa
- Klimaanlæg GE
- Klimaanlæg Daikin
- Klimaanlæg Zanussi
- Klimaanlæg CyberPower
- Klimaanlæg Panasonic
- Klimaanlæg Gorenje
- Klimaanlæg Tectro
- Klimaanlæg VOX
- Klimaanlæg Concept
- Klimaanlæg OK
- Klimaanlæg LG
- Klimaanlæg AEG
- Klimaanlæg Electrolux
- Klimaanlæg Bauknecht
- Klimaanlæg Whirlpool
- Klimaanlæg Mitsubishi
- Klimaanlæg Master
- Klimaanlæg Sharp
- Klimaanlæg Hotpoint
- Klimaanlæg Melissa
- Klimaanlæg ARGO
- Klimaanlæg Qlima
- Klimaanlæg Daewoo
- Klimaanlæg Korona
- Klimaanlæg Arçelik
- Klimaanlæg Soler & Palau
- Klimaanlæg Sanyo
- Klimaanlæg Baxi
- Klimaanlæg Grundig
- Klimaanlæg Progress
- Klimaanlæg Hotpoint Ariston
- Klimaanlæg Livoo
- Klimaanlæg Toshiba
- Klimaanlæg Klarstein
- Klimaanlæg Furrion
- Klimaanlæg Infiniton
- Klimaanlæg Trisa
- Klimaanlæg Matsui
- Klimaanlæg Nedis
- Klimaanlæg Emerio
- Klimaanlæg Bartscher
- Klimaanlæg Be Quiet!
- Klimaanlæg Sauber
- Klimaanlæg Westinghouse
- Klimaanlæg Element
- Klimaanlæg Thomson
- Klimaanlæg Hyundai
- Klimaanlæg AKAI
- Klimaanlæg Hisense
- Klimaanlæg TriStar
- Klimaanlæg Brandt
- Klimaanlæg Adler
- Klimaanlæg Camry
- Klimaanlæg Dometic
- Klimaanlæg Eurom
- Klimaanlæg TecLime
- Klimaanlæg Trotec
- Klimaanlæg Blaupunkt
- Klimaanlæg Einhell
- Klimaanlæg Becken
- Klimaanlæg BEKO
- Klimaanlæg Honeywell
- Klimaanlæg Clatronic
- Klimaanlæg Hitachi
- Klimaanlæg Rowenta
- Klimaanlæg Ariston Thermo
- Klimaanlæg Haier
- Klimaanlæg Truma
- Klimaanlæg Bomann
- Klimaanlæg Innoliving
- Klimaanlæg Zelmer
- Klimaanlæg Vivax
- Klimaanlæg Thermex
- Klimaanlæg Vaillant
- Klimaanlæg Alaska
- Klimaanlæg Zanker
- Klimaanlæg Galanz
- Klimaanlæg Amana
- Klimaanlæg Amcor
- Klimaanlæg Carrier
- Klimaanlæg Comfee
- Klimaanlæg Gree
- Klimaanlæg Dimplex
- Klimaanlæg Tripp Lite
- Klimaanlæg Primo
- Klimaanlæg Orbegozo
- Klimaanlæg Malmbergs
- Klimaanlæg Sigma
- Klimaanlæg Koenig
- Klimaanlæg Taurus
- Klimaanlæg Xiaomi
- Klimaanlæg Exquisit
- Klimaanlæg HQ
- Klimaanlæg Proklima
- Klimaanlæg Elba
- Klimaanlæg Air Breeze
- Klimaanlæg Fujitsu
- Klimaanlæg Inventor
- Klimaanlæg MPM
- Klimaanlæg Toyotomi
- Klimaanlæg Frigor
- Klimaanlæg TOSOT
- Klimaanlæg APC
- Klimaanlæg Domo
- Klimaanlæg Ferroli
- Klimaanlæg Saunier Duval
- Klimaanlæg Heylo
- Klimaanlæg Olimpia Splendid
- Klimaanlæg Aspes
- Klimaanlæg Eden
- Klimaanlæg Blumfeldt
- Klimaanlæg Inventum
- Klimaanlæg Altech
- Klimaanlæg Carson
- Klimaanlæg Fakir
- Klimaanlæg White Knight
- Klimaanlæg Dantherm
- Klimaanlæg Khind
- Klimaanlæg Frigidaire
- Klimaanlæg Frilec
- Klimaanlæg Evolar
- Klimaanlæg Ridgid
- Klimaanlæg Ardes
- Klimaanlæg Suntec
- Klimaanlæg SVAN
- Klimaanlæg Everglades
- Klimaanlæg Danby
- Klimaanlæg RCA
- Klimaanlæg ECG
- Klimaanlæg General Electric
- Klimaanlæg Eldom
- Klimaanlæg H.Koenig
- Klimaanlæg Sonnenkönig
- Klimaanlæg Termozeta
- Klimaanlæg OneConcept
- Klimaanlæg Stirling
- Klimaanlæg Just Fire
- Klimaanlæg Be Cool
- Klimaanlæg Duux
- Klimaanlæg ElectriQ
- Klimaanlæg Kalorik
- Klimaanlæg Cecotec
- Klimaanlæg Airwell
- Klimaanlæg Anslut
- Klimaanlæg MundoClima
- Klimaanlæg Jocca
- Klimaanlæg Orima
- Klimaanlæg SereneLife
- Klimaanlæg Remko
- Klimaanlæg Friedrich
- Klimaanlæg Whynter
- Klimaanlæg Philco
- Klimaanlæg Fuave
- Klimaanlæg Avidsen
- Klimaanlæg Climadiff
- Klimaanlæg Kogan
- Klimaanlæg Ravanson
- Klimaanlæg Airlux
- Klimaanlæg Jocel
- Klimaanlæg Ufesa
- Klimaanlæg Keystone
- Klimaanlæg ActronAir
- Klimaanlæg Orava
- Klimaanlæg NewAir
- Klimaanlæg IFB
- Klimaanlæg Create
- Klimaanlæg Daitsu
- Klimaanlæg Daizuki
- Klimaanlæg Profile
- Klimaanlæg AireMax
- Klimaanlæg Aconatic
- Klimaanlæg Aermec
- Klimaanlæg Acson
- Klimaanlæg Andrews
- Klimaanlæg Akira
- Klimaanlæg Aircooler
- Klimaanlæg Airview
- Klimaanlæg Aertesi
- Klimaanlæg Royal Sovereign
- Klimaanlæg Alberello
- Klimaanlæg Salton
- Klimaanlæg Haverland
- Klimaanlæg Rasonic
- Klimaanlæg Mabe
- Klimaanlæg Heinner
- Klimaanlæg Nabo
- Klimaanlæg AlpicAir
- Klimaanlæg Kelvinator
- Klimaanlæg Tatung
- Klimaanlæg Milectric
- Klimaanlæg Lloyd
- Klimaanlæg Alpatec
- Klimaanlæg Godrej
- Klimaanlæg Maiko
- Klimaanlæg Aircool
- Klimaanlæg Edgestar
- Klimaanlæg Maxicool
- Klimaanlæg Argoclima
- Klimaanlæg Home Electric
- Klimaanlæg Tarrington House
- Klimaanlæg Gutfels
- Klimaanlæg Telair
- Klimaanlæg Klarbach
- Klimaanlæg Mobile Airco
- Klimaanlæg Heiko
- Klimaanlæg Qlima - Zibro
- Klimaanlæg VänEE
- Klimaanlæg Handson
- Klimaanlæg Bryant
- Klimaanlæg Klima1stKlaas
- Klimaanlæg Emmeti
- Klimaanlæg Evapolar
- Klimaanlæg ARCTIC WIND
- Klimaanlæg Perfect Aire
- Klimaanlæg TechnoLife
- Klimaanlæg Shinco
- Klimaanlæg Innova
- Klimaanlæg D-Let
- Klimaanlæg Domair
- Klimaanlæg SEEGER
- Klimaanlæg Thermo Comfort
- Klimaanlæg Mizushi
- Klimaanlæg Sinclair
- Klimaanlæg Arcoaire
- Klimaanlæg Zymbo
- Klimaanlæg GoldAir
- Klimaanlæg Kostal
- Klimaanlæg SMD
- Klimaanlæg Commercial Cool
- Klimaanlæg Coolix
- Klimaanlæg Omega Altise
- Klimaanlæg Koldfront
- Klimaanlæg Yamazen
- Klimaanlæg Corona
- Klimaanlæg Symphony
- Klimaanlæg Universal Blue
Nyeste Klimaanlæg Manualer
21 December 2024
21 December 2024
18 December 2024
18 December 2024
18 December 2024
13 December 2024
10 December 2024
25 November 2024
24 November 2024
24 November 2024