Minox DC 6022 Manual


Læs nedenfor 📖 manual på dansk for Minox DC 6022 (2 sider) i kategorien Ikke kategoriseret. Denne guide var nyttig for 8 personer og blev bedømt med 4.5 stjerner i gennemsnit af 2 brugere

Side 1/2
See reverse side for more information
10/12
BC266
Users Manual for Biometric Safe
* Actual model may vary
A. Initialization Button
B. Battery Compartment
C. Bolts
D. Fingerprint Scanner
E. Indicator Lights
F. Wake-Up Button
GETTING STARTED
1. Remove Emergency Keys from accessory package
2. To expose the Emergency Key access, remove Logo Plate
(G) screws with provided tool
3. Insert Emergency Key into key access, push and turn
counter-clockwise
4. Turn Handle (H) clockwise to open the safe
5. Continue with INSTALL BATTERIES
INSTALL BATTERIES
1. Remove Battery Compartment (B) cover
2. Insert 4 AA batteries and restore battery cover
3. Continue with FINGERPRITN REGISTRATION
FINGERPRINT REGISTRATION
IMPORTANT: The safe is in either Pre-registered mode or
Factory Default mode, test safe to determine factory settings
below
Pre-registered mode: Safe can NOT be opened with any
fingerprint(s)
Factory Default mode: Safe can be opened with ANY
fingerprint(s)
1. With the safe door open, press and release Initialization
Button (A)
2. Immediately place a finger on the Fingerprint Scanner (D)
- Hold finger still
- 1 beep will be heard recognizing the fingerprint; followed by
2 consecutive beeps
- Remove finger
- Registration is complete
Successful Registration
Registration is successful when a total of 3 beeps are heard
Unsuccessful Registration
2 short beeps will be heard; repeat registration process again
3. To register another fingerprint - repeat steps 1 – 2
4. Continue with TEST (NON) REGISTERED FINGERPRINTS
TEST (NON) REGISTERED FINGERPRINTS
1. Test multiple Non-Registered fingerprints
- Close safe door, turn Handle (H) counter-clockwise to
lock the safe
- Press and release Wake-Up Button (F)
- Place a non-registered finger on the Fingerprint Scanner (D)
- Turn Handle (H) clockwise, the door should not open
- If the door opens with a non-registered fingerprint,
registration was unsuccessful; the safe is still in Factory
Default mode
- Repeat steps under FINGERPRINT REGISTRATION, and
test multiple non-registered fingerprints
2. Test a Registered fingerprint
- With door closed, press and release Wake-Up Button (F)
- Place a registered finger on the Fingerprint Scanner (D)
- Turn Handle (H) clockwise, the door should open
- Registration was successful, if it only opened with registered
fingerprint(s)
CLOSE/OPEN SAFE DOOR
CLOSE: Close safe door, turn Handle (H) counter-clockwise to
lock the safe
OPEN: Press and release Wake-Up Button (F)
- Place a registered finger on Fingerprint Scanner (D)
- Turn Handle (H) clockwise to open the safe
BEEP SOUND OPTIONS
Beep OFF: Press and HOLD the Initialization Button (A) (20 -
30 seconds) until the Indicator Lights (E) flash green once
- RELEASE the Initialization Button
Beep ON: Press and HOLD the Initialization Button (A) (20 -
30 seconds) until the Indicator Lights (E) flash green, followed
by 1 beep
- RELEASE the Initialization Button
OPEN SAFE WITH EMERGENCY KEY
1. To expose the Emergency Key access, remove Logo
Plate (G) screws with provided tool
2. Insert Emergency Key into key access, push and turn key
counter-clockwise, and turn Handle (H) clockwise to open
the safe
NOTE: Store Emergency Keys in a secure place, NOT inside of
the safe
OPEN SAFE WITH EXTERNAL BATTERY PACK
Use this option when internal batteries are low
1. Insert 4 AA batteries into External Battery Pack (I)
2. Plug into External Battery Access (J)
G. Logo Plate and Emergency
Key Access
H. Handle
I. External Battery Pack
(batteries not included)
J. External Battery Access
WARNING
- New Safe is in either Pre-registered mode or Factory
Default mode; ANY fingerprint can open the safe. Only
a successfully registered Fingerprint(s) can terminate
Factory Default mode.
- Register at least two different fingerprints and test a
few times before closing the safe door.
- Test with a non-registered fingerprint. If the safe
opens, the safe is still in Factory Default mode.
- Avoid leaving safe door open and unattended; it will
allow unauthorized individuals to add their fingerprints
and/or reprogram the safe, gaining full access to the
safe and the contents.
- Test the Emergency Keys and store them in a secure
place, NOT inside of the safe.
- To maximize the security and performance of the
safe, test registered fingerprints every 6 months.
- Initialization button cover must be restored after
every use.
- If user resets the safe to Factory Default mode: ANY
fingerprint can open the safe.
A
B
C
F
D
E
G
HH
HJ
I
L
o
c
k
U
n
l
o
c
k
Read all instructions before using this safe.


Produkt Specifikationer

Mærke: Minox
Kategori: Ikke kategoriseret
Model: DC 6022

Har du brug for hjælp?

Hvis du har brug for hjælp til Minox DC 6022 stil et spørgsmål nedenfor, og andre brugere vil svare dig




Ikke kategoriseret Minox Manualer

Minox

Minox RS-4 Manual

2 September 2024
Minox

Minox MS 8x25 Manual

2 September 2024
Minox

Minox ZP 8 Manual

2 September 2024
Minox

Minox DD 100 Manual

25 August 2024
Minox

Minox 35 PE Manual

25 August 2024
Minox

Minox DC 9011 Manual

25 August 2024
Minox

Minox B Manual

25 August 2024
Minox

Minox LX Manual

25 August 2024
Minox

Minox DC 6022 Manual

25 August 2024
Minox

Minox DC 8011 Manual

25 August 2024

Ikke kategoriseret Manualer

Nyeste Ikke kategoriseret Manualer

Elektron

Elektron Overbridge Manual

26 November 2024
Elektron

Elektron Sidstation Manual

26 November 2024
SoundTube

SoundTube IPD-RS82-EZ Manual

26 November 2024
Kramer

Kramer 4x1VB Manual

26 November 2024
Kramer

Kramer RC-63A Manual

26 November 2024
SoundTube

SoundTube IPD-HP82-EZ Manual

26 November 2024
Kramer

Kramer RK-KVM-1U-PP3 Manual

26 November 2024
Gioteck

Gioteck VX-2 (PS3) Manual

26 November 2024