Oregon Scientific RM308P Manual


Læs nedenfor 📖 manual på dansk for Oregon Scientific RM308P (10 sider) i kategorien Clockradio. Denne guide var nyttig for 12 personer og blev bedømt med 4.5 stjerner i gennemsnit af 2 brugere

Side 1/10
Classic dual-alarm projection clock
Model: RM308P / RM308PA /
RM308PU / RA308PH
USER MANUAL
OVERVIEW
FRONT VIEW
1
2
11
12
13
14
3
4
5
6
789
10
1. SNOOZE / LIGHT: activate snooze alarm; activate
backlight
2. : signal reception indicator
3. : main unit batteries low / no battery
4. PM: indicate PM
5. : alarm time is displayed
6. Alarm time / calendar
7. : change settings / display MODE
8. : view alarm status; set alarm; change to alarm /
calendar display
9. ON : activate / deactivate alarm functionOFF
10. / : increase / decrease values of the selected
setting; enable / disable clock reception signal
11. Projector: project time / alarm status
12. Clock with seconds / weekday
13. Time zone offset
14. Alarm 1, 2 is ON
REAR VIEW
1
2
3
4
1. : focus the projected image FOCUS
2. : reset unit to default settings RESET
3. PROJECTION ON/OFF: enable / disable continuous
projection
4. AC adaptor socket
BOTTOM VIEW
1. Battery compartment
GETTING STARTED
POWER SUPPLY
2 x UM-4 (AAA) batteries
To insert batteries:
1. Remove the battery compartment cover.
2. Insert the batteries, matching the polarities (+/ -).
3. Press RESET after each battery change.
MEANING
Battery is low in power
No battery installed – only AC adaptor
1 x adaptor
Alternatively, use the adaptor supplied to power the unit. For
continuous use of projector, adaptor must be installed.
Make sure the adapter is not obstructed and is easily
accessible to the unit.
NOTE The main unit and adaptor should not be exposed to
wet conditions. No objects filled with liquid, such as vases,
should be placed on the main unit and adaptor.
To completely disconnect from power, the adaptor should be
disconnected from the mains.
CLOCK
CLOCK RECEPTION
This product is designed to synchronize its clock automatically
with a clock signal.
RM308P:
EU: DCF-77 signal: within 1500 km (932 miles) of
Frankfurt, Germany.
RM308PA:
US: WWVB-60 signal: within 3200km (2000 miles) of
Fort Collins Colorado.
RM308PU:
UK: MSF-60 signal: within 1500 km (932 miles) of
Anthorn, England.
To enable / disable signal reception:
Press and hold to enable or to disable signal
reception.
NOTE Reception takes 2-10 minutes. If the signal is weak,
it can take up to 24 hours to get a valid signal.
Clock signal reception indicator:
Strong signal Weak / No signal
If signal reception is unsuccessful, place your unit next to a
window, press and hold to force another signal search.
MANUALLY SET CLOCK
To set the clock manually, disable the clock signal reception
first.
1. Press and hold to enter.MODE
2. Press MODE to toggle between displays.
3. Press or to increase / decrease values of the
selected setting.
4. Press MODE to conrm.
The settings order is: time zone offset, 12/24 hr format,
hour, minute, year, month-day / day-month, month, day and
language.
Time zone offset sets the clock +/- 23 hours from the received
clock signal time. If you have deactivated the clock signal
reception, do not set a value for time zone.
NOTE If you enter +1 in the time zone setting, this will give
you your regional time plus 1 hour.
If you are in the US (RM308PA only) set the clock to:
PA for Pacific time MO for Mountain time
CE for Central time EA for Eastern time
NOTE The language options are English (E), German (D),
French (F), Italian (I), and Spanish (S).
ALARM
To set the alarm:
1. Press ALARM to toggle between Alarm 1 / 2.
2. Press and hold to enter alarm setting.ALARM
3. Press / to set hour / minute.
4. Press ALARM MODE or to conrm.
/ indicates alarm is ON.
To activate / deactivate alarm 1 and / or 2:
1. Press to select Alarm 1 or 2.
2. Press and hold .
To silence the alarm:
Press SNOOZE LIGHT / to silence it for 8 minutes
OR
Press any other key to turn the alarm off and activate it
again after 24 hours.
To select display mode:
Press MODE to toggle between displays (alarm,
calendar with seconds and calendar with weekday).
PROJECTION
To activate projection / backlight:
Press SNOOZE / LIGHT.
To activate / deactivate continuous projection:
Slide PROJECTION switch to ON/OFF when adaptor is
connected.
To flip image 180° (while image is projected):
Within 5 seconds of pressing SNOOZE / LIGHT, press
SNOOZE / LIGHT again.
To focus image:
Turn FOCUS wheel.
NOTE If projection is illuminated, do not look directly into
the projector.
RESET
Press to return to the default settings.RESET
PRECAUTIONS
Do not subject the unit to excessive force, shock, dust,
temperature or humidity.
Do not cover the ventilation holes with any items such as
newspapers, curtains etc.
Do not immerse the unit in water. If you spill liquid over
it, dry it immediately with a soft, lint-free cloth.
Do not clean the unit with abrasive or corrosive
materials.
Do not tamper with the unit’s internal components. This
invalidates the warranty.
Only use fresh batteries. Do not mix new and old
batteries.
Images shown in this manual may differ from the actual
display.
When disposing of this product, ensure it is collected
separately for special treatment and not as normal
household waste.
Placement of this product on certain types of wood
EN
may result in damage to its nish for which Oregon
Scientic will not be responsible. Consult the furniture
manufacturer's care instructions for information.
The contents of this manual may not be reproduced
without the permission of the manufacturer.
Do not dispose old batteries as unsorted municipal
waste. Collection of such waste separately for special
treatment is necessary.
Please note that some units are equipped with a
battery safety strip. Remove the strip from the battery
compartment before rst use.
NOTE The technical specifications for this product and the
contents of the user manual are subject to change without
notice.
NOTE Features and accessories will not be available in all
countries. For more information, please contact your local
retailer.
SPECIFICATIONS
TYPE DESCRIPTION
L x W x H 145 x 94 x 40 mm
(5.7 x 3.7 x 1.6 in)
Weight 157 g ( 5.5 oz) without battery
Power AC/DC 4.5V adaptor
2 x UM-4 (AAA) 1.5 V batteries
ABOUT OREGON SCIENTIFIC
Visit our website (www.oregonscientific.com) to learn more
about Oregon Scientific products.
If you’re in the US and would like to contact our Customer
Care department directly, please visit: www2.oregonscientific.
com/service/support.asp
For international inquiries, please visit: www2.oregonscientific.
com/about/international.asp
EU-DECLARATION OF CONFORMITY
Hereby, Oregon Scientific, declares that this Classic dual-alarm
projection clock (model: RM308P / RM308PA / RM308PU /
RA308PH) is in compliance with the essential requirements
and other relevant provisions of Directive 1999/5/EC. A copy of
the signed and dated Declaration of Conformity is available on
request via our Oregon Scientific Customer Service.
COUNTRIES RTTE APPROVAL COMPLIED
All EU countries, Switzerland CH
and Norway N
FCC STATEMENT
This device complies with Part 15 of the FCC Rules. Operation
is subject to the following two conditions: (1) This device may
not cause harmful interference, and (2) This device must
accept any interference received, including interference that
may cause undesired operation.
WARNING Changes or modifications not expressly approved
by the party responsible for compliance could void the user’s
authority to operate the equipment.
NOTE This equipment has been tested and found to comply
with the limits for a Class B digital device, pursuant to Part
15 of the FCC Rules. These limits are designed to provide
reasonable protection against harmful interference in a
residential installation.
This equipment generates, uses and can radiate radio
frequency energy and, if not installed and used in accordance
with the instructions, may cause harmful interference to
radio communications. However, there is no guarantee
that interference will not occur in a particular installation. If
this equipment does cause harmful interference to radio or
television reception, which can be determined by turning the
equipment off and on, the user is encouraged to try to correct
the interference by one or more of the following measures:
Reorient or relocate the receiving antenna.
Increase the separation between the equipment and
receiver.
Connect the equipment into an outlet on a circuit different
from that to which the receiver is connected.
Consult the dealer or an experienced radio / TV
technician for help.
DECLARATION OF CONFORMITY
The following information is not to be used as contact for
support or sales. Please call our customer service number
(listed on our website at www.oregonscientific.com), or on the
warranty card for this product) for all inquiries instead.
We
Name: Oregon Scientific, Inc.
Address: 19861 SW 95
th Ave.,Tualatin,
Oregon 97062 USA
Telephone No.: 1-800-853-8883
declare that the product
Product No.: RM308P / RM308PA / RM308PU /
RA308PH
Product Name: Classic dual-alarm projection clock
Manufacturer: IDT Technology Limited
Address: Block C, 9/F, Kaiser Estate,
Phase 1, 41 Man Yue St.,
Hung Hom, Kowloon,
Hong Kong
is in conformity with Part 15 of the FCC Rules. Operation is
subject to the following two conditions: 1) This device may not
cause harmful interference. 2) This device must accept any
interference received, including interference that may cause
undesired operation.


Produkt Specifikationer

Mærke: Oregon Scientific
Kategori: Clockradio
Model: RM308P

Har du brug for hjælp?

Hvis du har brug for hjælp til Oregon Scientific RM308P stil et spørgsmål nedenfor, og andre brugere vil svare dig




Clockradio Oregon Scientific Manualer

Clockradio Manualer

Nyeste Clockradio Manualer

AKAI

AKAI AR 175D Manual

16 December 2024
Vimar

Vimar 20449.N Manual

15 December 2024
Vimar

Vimar 14449 Manual

15 December 2024
Vimar

Vimar 20449.B Manual

15 December 2024
Vimar

Vimar 20449 Manual

15 December 2024
Vimar

Vimar 16573 Manual

15 December 2024
Vimar

Vimar 14449.SL Manual

15 December 2024
TFA

TFA Sonio 60.2514 Manual

14 December 2024
TFA

TFA 60.2551.01 Manual

14 December 2024
TFA

TFA 60.1511.02 Manual

14 December 2024