Oricom HNA300 Manual


Læs nedenfor 📖 manual på dansk for Oricom HNA300 (2 sider) i kategorien Baby-produkt. Denne guide var nyttig for 26 personer og blev bedømt med 4.5 stjerner i gennemsnit af 2 brugere

Side 1/2
1 2
43 5
Important Information
Introduction
Parts and Functions
Preparation
How to Use
How to Maintain and Storage of the Unit
Page 1
Page 3
Page 3
Page 4
Page 4
Page 5
Specifications
Warranty
Troubleshooting Page 6
Page 7
Page 8
HNA300 NASAL
ASPIRATOR
Contents
Important Information
Important Information
Keep this user guide for future reference. Always retain your proof
of purchase in case of warranty service.
Oricom HNA300 Nasal Aspirator is included as a medical device on the Australian
Register of Therapeutic Goods (ARTG No. 307470) and is intended to enable clearing of
excessive mucus from nasal passages of an infant/child to facilitate easier breathing.
Intended for domestic use only. ALWAYS READ THE USER GUIDE AND USE ONLY AS
DIRECTED. IF SYMPTOMS PERSIST SEE YOUR DOCTOR/HEALTHCARE PROFESSIONAL.
Use this product only for the intended purpose as described in this user guide.
WARNING
Do not insert the tip deep into baby’s nostril.
Should there be any health-related problems, discontinue use immediately and consult
your doctor.
Do not use HNA300 in the case of nasal irritation, haemorrhage, if any signs of
inflammation and or bleeding in the nose.
If your child experiences any skin or nasal irritation or redness after use, please stop
using the aspirator and consult your doctor.
Aspiration time should be limited to 15 seconds per minute MAX.
HNA300 is not a toy and must be used by adults only after reading this User Guide.
Keep HNA300 nasal aspirator and nozzle pieces out of children’s reach or people with
reduced physical or mental abilities. NOTE: The reservoir nozzle piece is not sterile.
Keep USB cable out of reach of children.
This product will require a USB charger rated at 5V 2A to recharge the battery.
PRECAUTIONS
Using your HNA300 without a nozzle piece or keeping the switch on when the reservoir
is full, will drain the battery quickly.
Before using the HNA300, make sure that all parts are correctly assembled.
Do not attempt to disassemble the nasal aspirator main unit or the nozzle pieces.
Do not use if damaged.
Do not expose to direct sunlight or leave in a high temperature environment.
Only use the suction nozzles pieces provided with this nasal aspirator.
Never use on ears, mouth, or eyes.
Clean after every use, do not use harsh chemicals or solvents. Refer to the cleaning
instructions in this user guide.
This nasal aspirator is designed for indoor use only.
Do not use in conjunction with any nuclear magnetic resonance or CT equipment.
Your nasal aspirator is designed to work within the operating temperatures and
humidity listed in the specifications. Using it outside these parameters will lead to
malfunction.
Do not use your nasal aspirator in a bathroom or any environment of elevated humidity
(e.g. sauna, hydrotherapy etc.)
Do not expose the nasal aspirator to electric shock.
Do not use the device in flammable gas.
Cease use if your nasal aspirator starts to operate erratically or malfunction.
For assistance, in setting up, using or maintenance of your HNA300, please contact
Oricom.
WARNING: This product is not a toy, keep out of reach of children. Rechargeable Lithium
Ion batteries are potentially hazardous and can present a serious fire hazard if damaged,
defective or improperly used. Do not leave your product unattended whilst charging the
battery.
This product does not include any user serviceable parts. DO NOT DISASSEMBLE the
base of this product. Dispose of this product which includes a lithium battery in
accordance with local disposal waste regulations. Risk of suffocation! Keep all packaging
materials out of reach of children.
How to Maintain and storage of the Unit
1) Cleaning after use
Disconnect the combined suction tip from the device.
Twist the collection cup to remove the contents.
Disconnect collection cup from the main body.
To clean the main body and all parts connected to it, rinse with the operation button
facing downwards and then wipe to clean with an antibacterial wipe.
Ensure all parts are completely dry before reassembling.
NOTE: The product should not be operated during any of the cleaning process.
WARNING: The nasal aspirator is NOT waterproof. Do NOT submerge the main body
in water.
2) Cleaning the suction tip
To clean the disconnected suction tip, disinfect it in boiling water and keep it clean.
Ensure all parts are completely dry before reassembling.
WARNING: The nasal aspirator is NOT waterproof. Do NOT submerge the main
body in water.
3) Typical service life
- The lithium-polymer rechargeable battery should endure approximately 300 charge cycles.
HNA- 300
Nasal Aspirat o r
Ke e p this us e r guide for future re fe re nce . A lways re ta in your proo f
of purchase in case of warranty s e rvice .
Intended Use
- This device is designed to remove the nasal mucus in children.
Children who are (typically under the age of 6) unable to remove the nasal mucus by
blowing their noses.
Intended purpose
- To eliminate clogging of the nose
- To ensure nasal breathing to infants
- To relieve childhood allergy-like symptoms by removing the nasal mucus
Introduction
Parts and Functions
Preparation
- Do NOT suction water or any other liquid.
- Do NOT allow mucus and fluid to exceed 50 percent capacity.
- Make sure nasal aspirator is turned off prior to removing collection cup for cleaning.
- Do NOT submerge in water or any other liquid.
WARNING
Open the aspirator cover.
Place the suction tip securely
on collection cup.
Press and hold the power
button to begin suction.
Gently place the suction tip
into the baby's nose, and
allow the suction to clear the
mucus.
When the suction is
complete, release the power
button.
Clean nasal aspirator after
use.
2) Electronic Suction
How to Use
Protection Cover
LED Indicator
-Charging : Yellow light
-Charged : Green light
-Low battery : Red light
-Working : Green blink
Power Button
Tip 1
Collection cup
Battery Charging Connector
Tip 2
1
2
5
6
3
4
7
Charging Cable
Tip 1 Tip 2
User Manual
Main Unit
1) Collection Cup Assembly/Disassembly
- Make sure your nasal aspirator is turned off.
Press and hold the power
button to begin suction.
Product connection
Combine the connection portion of collection cup with collection
cup. Turn the collection cup in the direction of the arrow to
connect it with main unit.
Connect the suction nose
to the main unit.
Insert O-Ring to
the collection cup.
How to Use
1) Charging
- Power off your nasal aspirator.
- Only charge your nasal aspirator when the LED is flashing red.
- LED flashing red indicates low battery.
Connect the USB cable to a charging device (DC5V.2A).
Connect the micro-USB end of the Cable to Nasal aspirator.
LED indicator is yellow when charging.
LED indicator is green when charging is complete.
- Only Use the charging cable supplied by Oricom.
- Charging time is 2 hours.
CAUTION


Produkt Specifikationer

Mærke: Oricom
Kategori: Baby-produkt
Model: HNA300

Har du brug for hjælp?

Hvis du har brug for hjælp til Oricom HNA300 stil et spørgsmål nedenfor, og andre brugere vil svare dig




Baby-produkt Oricom Manualer

Oricom

Oricom Secure 745 Manual

29 December 2024
Oricom

Oricom 08KBEAR Manual

22 Oktober 2024
Oricom

Oricom OLS150 Manual

24 August 2024
Oricom

Oricom 08CAT Manual

20 August 2024
Oricom

Oricom OLS100 Manual

18 August 2024
Oricom

Oricom OS10 Manual

16 August 2024
Oricom

Oricom OBH930 Manual

16 August 2024
Oricom

Oricom OBHSSOO Manual

15 August 2024

Baby-produkt Manualer

Nyeste Baby-produkt Manualer