PAC IGN-3 Manual


Læs nedenfor 📖 manual på dansk for PAC IGN-3 (1 sider) i kategorien Ikke kategoriseret. Denne guide var nyttig for 4 personer og blev bedømt med 4.5 stjerner i gennemsnit af 2 brugere

Side 1/1
© 2018 AAMP Global. All rights reserved. PAC is a Power Brand of AAMP Global.
PAC-audio.com
C
Rev. 101118
The IGN-3 phantom ignition module is ideal for use in CAN-Bus vehicles, and vehicles with stop-start technology, commonly
found in push-to-start vehicles, or Hybrid vehicles. It monitors the electrical activity in the vehicle and provides an ignition lead
that provides voltage as soon as the engine is running (accessory function for CAN-Bus vehicles).
Introduction and Features
Wiring Information
Operation
Troubleshooting
LED is not flashing - Using a Multimeter, check that there is 12 volts present on the Red wire, and a solid ground connection
on the Black wire.
Aftermarket accessory is shutting off while vehicle is running - If your installation requires a longer accessory output,
cut the Brown Loop wire to increase the power-off delay to 140 seconds, to ensure continued operation of aftermarket products.
IGN-3 Power-off Delay Function:
In many late-model vehicles, the alternator can shut off while the vehicle is driving, to maximize fuel economy. Other new
vehicles will shut the engine down when stopped at a red light, and start it up again when the accelerator is pressed.
The IGN-3 is designed with 2 different power-off delay settings, that can be used to compensate for these vehicle functions.
A short delay of 10 seconds, or a long delay of 140 seconds are available, to provide consistent power to your aftermarket
accessories, to ensure their proper operation during these partial power-down scenarios.
In the default setting (Brown loop wire uncut), after the vehicle’s engine is turned off, the Blue wire output will remain
active for 10 seconds. If the Brown Loop wire is cut, the Blue wire will remain active for 140 seconds after engine shutdown.
LED information:
If the LED is flashing once every three seconds, the module is in standby mode, ready to sense the vehicle’s engine start.
If the LED is illuminated solid. The (Blue) phantom ignition output wire is active.
1. Black - Connect to chassis ground
2. Blue - 12 volt output (once triggered) 2 amps max.
3. Red - Connect to Constant Power
4. Brown Loop - Uncut loop = 10 second delay
IGN-3 is designed to provide up to 2 amps of output.
For installations demanding more current, the use of an external relay is required.
IGN-3 Power-on Function:
The IGN-3 module monitors the voltage level and noise on the constant power circuit to sense the starting of the engine and
running of the alternator, and immediately turns on the phantom ignition output (Blue wire).
- Cut loop = 140 second delay
IGN-3 Phantom Ignition Module for CAN-Bus Vehicles
and Vehicles with Stop-Start Technology
IGN-3
Phantom Ignition Module for
CAN-Bus Vehicles and Vehicles
with Stop-Start Technology
Made in China


Produkt Specifikationer

Mærke: PAC
Kategori: Ikke kategoriseret
Model: IGN-3

Har du brug for hjælp?

Hvis du har brug for hjælp til PAC IGN-3 stil et spørgsmål nedenfor, og andre brugere vil svare dig




Ikke kategoriseret PAC Manualer

PAC

PAC RP4-GM31 Manual

6 September 2024
PAC

PAC NU-CTS2 Manual

6 September 2024
PAC

PAC TR7 Manual

6 September 2024
PAC

PAC OS-5 Manual

6 September 2024
PAC

PAC NDK735MG Manual

29 August 2024
PAC

PAC RP3-GM11 Manual

29 August 2024
PAC

PAC IR-X Manual

29 August 2024
PAC

PAC AAI-GM9 Manual

29 August 2024
PAC

PAC AAI-GM12 Manual

29 August 2024
PAC

PAC CP1-FRD2 Manual

29 August 2024

Ikke kategoriseret Manualer

Nyeste Ikke kategoriseret Manualer

Stamos

Stamos S-PLASMA 60U Manual

23 November 2024
Velbus

Velbus VMBPIRO-W-20 Manual

23 November 2024
Honor

Honor 90 Pro Manual

23 November 2024
Honor

Honor 80 SE Manual

23 November 2024
Medela

Medela Safe & Dry Manual

22 November 2024
Jane

Jane First Potty Manual

22 November 2024
Stamos

Stamos SPT10P805 Manual

22 November 2024