PAC TR7 Manual


Læs nedenfor 📖 manual på dansk for PAC TR7 (4 sider) i kategorien Ikke kategoriseret. Denne guide var nyttig for 6 personer og blev bedømt med 4.5 stjerner i gennemsnit af 2 brugere

Side 1/4
Pacific Accessory Corporation - 1502 S. Santa Fe Street, Santa Ana, CA 92705
www.pac-audio.com • techsupport@pac-audio.com
Page 1
1-5-05
S/W 1.2.4
The TR-7 is a universal trigger output module that has various user
programmable features combined into one unit. The user programmable
features are stored in non volatile memory. When triggered, the TR-7
can turn on the outputs as a pulsed, latched or a timed output. There
are two inputs, the GREEN wire is a positive input that senses voltages
as low as 0.8 volts and the BROWN wire is a negative input, both are
tied together internally which is, essentially, ONE trigger input.
There are 3 separate outputs, the BLUE wire is a positive 12 volt
output which has a maximum current rating of 2 amps. The WHITE
and ORANGE wires are negative outputs which have a maximum of
current rating of 150 milliamps. The timed output is user adjustable and
can be programmed up to 4 minutes and 15 seconds. What makes the
TR-7 unique is that it does not use a potentiometer to adjust the timer. The timer is set by programming TR-7 minutes and seconds with
a number. The time saved is accurate to the second +7% - 8%.
#1: Low voltage trigger. Supplies a 12 volt remote output for an aftermarket
amplifier when used with a stock head unit that does not have a remote
output. Use the TR-7 to supply a 12 volt output from a 5 volt remote
source, like from Ford radios. Use on some vehicles that have a
negative antenna output and convert to a positive output.
#2: Alpine video bypass. This will automatically bypass Alpine’s flip out monitor
video procedure. WARNING! It is dangerous (and illegal in most
states) for the driver to watch the TV/Video monitor while driving
the vehicle. The driver may be distracted from looking ahead and
an accident could occur. Install the TR-7 only in RV and Marine
applications where there is no parking/hand brake to interface to.
Do not install the TR-7 where the driver may be able to view the
monitor when driving.
#3: Latch and unlatch output from a pulsed input. Turn on headlights, neon
lights or radio from an alarm with a momentary output or from a
momentary switch.
#4: Double pulse output. Pulses outputs twice when trigger from a constant or
pulsed signal. Use for alarm applications where the unlock wire needs 2
pulses to unlock all doors.
#5: Closed loop circuit. Good for monitoring trailers on hitches by triggering an
aftermarket alarm if the trailer is disconnected from the vehicles hitch.
Also monitors stereo equipment in vehicles.
#6: Pulse extender/Delayed turnoff. Upon a constant or pulsed trigger, the
TR-7 will turn on the outputs. As soon as the trigger is disconnected,
turned off or at the end of a pulse, the timer will count up to the number
of seconds recorded, at which time the outputs will turn off. Good for
turning on headlights at night for convenience. Extend alarms output
from 1 second to 3 seconds for Mercedes vacuum door locks. (rev.2)
#7: Horn honking output. On older, aftermarket alarms, it may have been
difficult to disarm the alarm with the RF remote when the horn was
honking. This will give you a 2 second delay between honks, allowing
you to disarm the alarm. Unique horn honking to distinguish your
vehicle from others. Program between 1 and 5 honks before the 2
second delay.
Black (-) Chassis Ground
Green (+) 0.8-16 Volts Input Trigger
Red (+) 12 volts constant/switched
Brown (-) Input Trigger
Blue (+) 12 volt output-2 amps max
White (-) Output-150 ma. max
Orange (-) Output-150 ma. max
MODEL TR-7
Universal Trigger Output Module
OFF-ON
Programming switch must be turned off
after the TR-7 is programmed!
#8: Linear Actuator Controller. Open/close amplifier racks from a momentary
source like from a alarm’s negative output. Sequence is : Start, Stop,
Reverse, Stop.
#9: Door lock Pulse generator. Good for automatically locking and unlocking
door locks when ignition is turned on and off.
#10: Channel Splitter. Split 1 channel from an alarm to 2 outputs. Both outputs
are user programmable for pulse, latched or timed output.
#11: Pulses to constant output. Counts a number of user programmable
pulses within a user programmed time to turn on the outputs. Good for
triggering Vehicle tracking devices that need a constant trigger but the
factory alarm only has a pulsed output when triggered like flashing lights
or horn honking. Keeps factory alarm from triggering Vehicle tracking
device when arming or disarming.
#12: 3 timers in 1. Upon a constant trigger, all 3 outputs are user programmable
to delay before turning on outputs or turning on instantly then delay
before turning off outputs. Good for situations where you need more
than 1 timer but on a different timer period, without having multiple
modules.
#13: Pulses to latch/unlatch outputs. Upon a number of pulses within a user
programmable time, the outputs will latch. Upon a number of pulses
within a user programmable time the second time, the outputs will
unlatch. You may program how many pulses to latch and unlatch. Use to
turn on aftermarket driving lights by using existing parking light switch.
#14: Pulses to pulse output. Upon number of pulses within a user programmable
time, the outputs will pulse. Example, if you programmed to see 4
pulses, for every 4 pulses the TR-7 sees within a 5 second time period,
the outputs will pulse once.
#15: Pulses to timed output. Upon a number of pulses within 5 seconds, the
outputs will turn on and delay for the amount of programmed time, then
the outputs will turn off.
#16: Latching outputs #2. Good for turning on 2 sets of driving lights with one
momentary switch. 1st pulse will latch one wire. 2nd pulse will unlatch
first wire and latch second wire. 3rd pulse will latch both wires. 4th pulse
turns off both wires.
The basic descriptions below are the features that can be done with the TR-7. Each feature is assigned a Feature#. Please make note of which Feature# you are
going to use. Other unique projects/installs can also be derived from the TR-7, so PAC leaves it to the installer’s imagination to experiment with these features.
Basic Description of Features
TR-7
Universal Trigger Output Module
Pacific Accessory Corporation


Produkt Specifikationer

Mærke: PAC
Kategori: Ikke kategoriseret
Model: TR7

Har du brug for hjælp?

Hvis du har brug for hjælp til PAC TR7 stil et spørgsmål nedenfor, og andre brugere vil svare dig




Ikke kategoriseret PAC Manualer

PAC

PAC RP4-GM31 Manual

6 September 2024
PAC

PAC NU-CTS2 Manual

6 September 2024
PAC

PAC TR7 Manual

6 September 2024
PAC

PAC OS-5 Manual

6 September 2024
PAC

PAC NDK735MG Manual

29 August 2024
PAC

PAC RP3-GM11 Manual

29 August 2024
PAC

PAC IR-X Manual

29 August 2024
PAC

PAC AAI-GM9 Manual

29 August 2024
PAC

PAC AAI-GM12 Manual

29 August 2024
PAC

PAC CP1-FRD2 Manual

29 August 2024

Ikke kategoriseret Manualer

Nyeste Ikke kategoriseret Manualer

Wagner

Wagner 2K Smart Manual

4 November 2024
Moen

Moen EB500-E Manual

3 November 2024
Moen

Moen Aspen 5824CH Manual

3 November 2024
Luxman

Luxman MQ-88uSE Manual

3 November 2024
Luxman

Luxman CL-38uSE Manual

3 November 2024
Luxman

Luxman CL-1000 Manual

3 November 2024
Moen

Moen Aspen 5802CH Manual

3 November 2024
Luxman

Luxman SQ-38u Manual

3 November 2024
Moen

Moen Aspen 5818CH Manual

3 November 2024