INSTRUCTIONS CM282C
Technical Support Phone: 866-405-6654
Fax: 708-444-6993
E-mail: ncginfo@panduit.com
Page 1 of 1
Cable Capacity
Part Number UTP Cable
.187 dia.
SeTP Cable
.250 dia. Fiber
3mm dia.
Method 1
Method 1
Method 1
Method 2
Method 2
Method 2
WMP1E
WMPF1E
WMPFSE
WMPH2E
WMPHF2E
WMPLFSE
WMPLSE
WMPSE
96 72 312
72 48 192
48 32 144
24 16 72
32
16
24
12
96
48
Flange
The PatchLink cable manager is recommended for use with Panduit 24 or 48 port patch panels mounted above and below the manager.
When routing the cables for the patch panels, either of the following two methods are recommended to help maintain cable bend radius.
METHOD 1:For each row of 24 ports, place two cables in each slot on the manager.
Route half the cables through each of the wire retainers on the ends of the manager.
METHOD 2: If the cables are coming from one side of the rack, place 2 cables in each of the slots on the manager.
Wire
Retainer
Wire
Retainer
METHOD 1
METHOD 2
19” Rack
Screws
Finger
Finger
WMP1E (shown)
Cover
Part Numbers: WMP1E, WMPF1E,WMPFSE, WMPH2E, WMPHF2E, WMPLFSE,
WMPLSE, WMPSE
WMP1E
WMPF1E
WMPFSE
WMPH2E
WMPHF2E
WMPLFSE
WMPLSE
WMPSE
The hinged cover opens from the top or the
bottom. Pull flange to open and close cover.
P LATCH INK
Cable Management Horizontal Panels
Install the managers to the rack with the #12-24x.5 or M6 screws provided. Built-in
screw retention in mounting holes secures screws in manager during installation.
Install the covers to the manager by positioning cover flat against the front of the
manager fingers, then push to snap in place.
Note: The recommended assembly torque shall be 9+/-1 in-lb for #12-24 screws,
1+/-0.1 N-m for M6 screws.
NOTE: When using front and back WMPHs to manage cables on the rear of the rack, place 2 cables in each of the 12 slots in the rear of
the manager, for each row of 24 ports.


Produkt Specifikationer

Mærke: Panduit
Kategori: Ikke kategoriseret
Model: WMPFSE-E

Har du brug for hjælp?

Hvis du har brug for hjælp til Panduit WMPFSE-E stil et spørgsmål nedenfor, og andre brugere vil svare dig




Ikke kategoriseret Panduit Manualer

Panduit

Panduit PZICE Manual

15 December 2024
Panduit

Panduit PZICEA Manual

15 December 2024
Panduit

Panduit PZNDVK Manual

15 December 2024
Panduit

Panduit DIRLC9606RB1 Manual

11 December 2024
Panduit

Panduit EA001 Manual

9 December 2024
Panduit

Panduit FPONE2 Manual

14 November 2024
Panduit

Panduit FPONE3 Manual

14 November 2024
Panduit

Panduit FPONE1 Manual

14 November 2024
Panduit

Panduit FPONE4 Manual

14 November 2024
Panduit

Panduit NKHDMI Manual

18 Oktober 2024

Ikke kategoriseret Manualer

Nyeste Ikke kategoriseret Manualer

Atlona

Atlona AT-DVIF30S-IR Manual

29 December 2024
Atlona

Atlona AT-PRO3HD66M Manual

29 December 2024
Atlona

Atlona AT-3GSDI500 Manual

29 December 2024
BlueBuilt

BlueBuilt BBMAG2M Manual

29 December 2024
Atlona

Atlona AT-3GSDI-14 Manual

28 December 2024
Atlona

Atlona AT-COMP10SS Manual

28 December 2024
Atlona

Atlona AT-2VGA300SL Manual

28 December 2024
Atlona

Atlona AT-HD-V216 Manual

28 December 2024
Atlona

Atlona AT-VGA11S Manual

28 December 2024
True

True TC900 Manual

28 December 2024