RCF IPS 2.5K Manual

RCF Modtager IPS 2.5K

Læs nedenfor 📖 manual på dansk for RCF IPS 2.5K (32 sider) i kategorien Modtager. Denne guide var nyttig for 9 personer og blev bedømt med 4.5 stjerner i gennemsnit af 2 brugere

Side 1/32
OWNER’S MANUAL
MANUALE UTENTE
IPS 5.0K
IPS 2.5K
IPS 1.5K
PROFESSIONAL POWER AMPLIFIERS
3
CONTENTS
CONTENTS ..................................................................................................................................................................................... 3
ENGLISH
SAFETY PRECAUTIONS AND GENERAL INFORMATION .................................................................................................................... 4
DESCRIPTION ................................................................................................................................................................................. 8
UNPACKING, INSTALLATION AND COOLING .................................................................................................................................. 8
FRONT PANEL ................................................................................................................................................................................ 9
REAR PANEL ................................................................................................................................................................................ 10
WIRING ........................................................................................................................................................................................ 11
OPERATION MODES ..................................................................................................................................................................... 12
COOLING REQUIREMENTS ............................................................................................................................................................ 15
ITALIANO
AVVERTENZE PER LA SICUREZZA ................................................................................................................................................. 16
DESCRIZIONE ............................................................................................................................................................................... 20
DISIMBALLAGGIO, INSTALLAZIONE E RAFFREDDAMENTO ............................................................................................................ 20
PANNELLO FRONTALE .................................................................................................................................................................. 21
PANNELLO POSTERIORE ............................................................................................................................................................... 22
CABLAGGIO ................................................................................................................................................................................. 23
MODALITÀ DI FUNZIONAMENTO .................................................................................................................................................. 24
VENTILAZIONE ............................................................................................................................................................................. 27
DIMENSIONS ................................................................................................................................................................................ 28
SPECIFICATIONS ........................................................................................................................................................................... 29
4
SAFETY PRECAUTIONS AND GENERAL INFORMATION
Symbols used in this document give notice of important operating instructions and warnings which must be strictly followed.
CAUTION Important operating instructions: explains hazards that could damage a product,
including data loss
WARNING Important advice concerning the use of dangerous voltages and the potential
risk of electric shock, personal injury or death.
IMPORTANT NOTES Helpful and relevant information about the topic
SUPPORTS, TROLLEYS
AND CARTS
Information about the use of supports, trolleys and carts. Reminds to move with
extreme caution and never tilt.
WASTE DISPOSAL
This symbol indicates that this product should not be disposed with your
household waste, according to the WEEE directive (2012/19/EU) and your
national law.
IMPORTANT
This manual contains important information about the correct and safe use of the device. Before connecting and using this product,
please read this instruction manual carefully and keep it on hand for future reference. The manual is to be considered an integral part
of this product and must accompany it when it changes ownership as a reference for correct installation and use as well as for the
safety precautions. RCF S.p.A. will not assume any responsibility for the incorrect installation and / or use of this product.
SAFETY PRECAUTIONS
All the precautions, in particular the safety ones, must be read with special attention, as they provide important information.
1. This product is intended for instructed person only, as defined in the IEC 62368-1 3rd Ed. Interfaces at ES3 level present.
2. This equipment is not suitable for use in locations where children are likely to be present.
3. Power supply from mains.
a. The mains voltage is sufficiently high to involve a risk of electrocution; install and connect this product before plugging it
in.
b. Before powering up, make sure that all the connections have been made correctly and the voltage of your mains corresponds
to the voltage shown on the rating plate on the unit, if not, please contact your RCF dealer.
c. Protecting earthing terminal. The apparatus should be connected to a mains socket with a protective earth connection by
power cord o 3-pole power cord.
d. Protect the power cable from damage; make sure it is positioned in a way that it cannot be stepped on or crushed by
objects.
e. To prevent the risk of electric shock, never open this product: there are no parts inside that the user needs to access.
f. Be careful: in the case of a product supplied by manufacturer without a power cord, all power cords and plug assemblies
shall be in compliance with the requirements of the IEC 62368-1 and certified and suitable for use in the particular countries
where the product shall be installed.
g. Use the mains plug to disconnect the apparatus from the mains.
4. Make sure that no objects or liquids can get into this product, as this may cause a short circuit. This apparatus shall not be
exposed to dripping or splashing. No objects filled with liquid, such as vases, shall be placed on this apparatus. Do not use this
apparatus near water No naked sources (such as lighted candles) should be placed on this apparatus.
5
5. Never attempt to carry out any operations, modifications or repairs that are not expressly described in this manual. Contact your
authorized service centre or qualified personnel should any of the following occur:
- The product does not function (or functions in an anomalous way).
- The power cable has been damaged.
- Objects or liquids have got in the unit.
- The product has been subject to a heavy impact.
6. This product does not contain user replaceable fuses. Fuses replacement is a service operation and must be performed by qualified
personnel.
7. The fuse on the AC mains input may be on the neutral, the AC mains shall be disconnected to de-energize the phase.
8. If this product is not used for a long period, disconnect the power cable.
9. If this product begins emitting any strange odours or smoke, switch it off immediately and disconnect the power cable.
10. Do not connect this product to any equipment or accessories not foreseen. For suspended installation, only use the dedicated
anchoring points and do not try to hang this product by using elements that are unsuitable or not specific for this purpose. Also
check the suitability of the support surface to which the product is anchored (wall, ceiling, structure, etc.), and the components
used for attachment (screw anchors, screws, brackets not supplied by RCF etc.), which must guarantee the security of the system
/ installation over time, also considering, for example, the mechanical vibrations normally generated by transducers. To prevent
the risk of falling equipment, do not stack multiple units of this product unless this possibility is specified in the user manual.
11. RCF S.p.A. strongly recommends this product is only installed by professional qualified installers (or specialised
firms) who can ensure correct installation and certify it according to the regulations in force. The entire audio
system must comply with the current standards and regulations regarding electrical systems.
12. Supports, trolleys and carts.
The equipment should be only used on supports, trolleys and carts, where necessary, that are recommended by the
manufacturer. The equipment / support / trolley / cart assembly must be moved with extreme caution. Sudden stops, excessive
pushing force and uneven floors may cause the assembly to overturn. Never tilt the assembly.
13. There are numerous mechanical and electrical factors to be considered when installing a professional audio system (in addition
to those which are strictly acoustic, such as sound pressure, angles of coverage, frequency response, etc.).
14. Hearing loss. Exposure to high sound levels can cause permanent hearing loss. The acoustic pressure level that leads to hearing
loss is different from person to person and depends on the duration of exposure. To prevent potentially dangerous exposure to
high levels of acoustic pressure, anyone who is exposed to these levels should use adequate protection devices. When a transducer
capable of producing high sound levels is being used, it is therefore necessary to wear ear plugs or protective earphones. See the
manual technical specifications to know the maximum sound pressure level.
OPERATING PRECAUTIONS
- Install the product in accordance with manufacturer’s instructions, in order to do not block any ventilation openings.
- Place this product far from any heat sources.
- Do not overload this product for a long time.
- Never force the control elements (keys, knobs, etc.).
- Do not use solvents, alcohol, benzene or other volatile substances for cleaning the external parts of this product.
WIRING
This product requires Class 2 output wiring.
6
IMPORTANT
To prevent the occurrence of noise on line signal cables, use screened cables only and avoid putting them close to:
- Equipment that produces high-intensity electromagnetic fields
- Power cables
- Loudspeaker lines
WARNING! CAUTION! To prevent the risk of fire or electric shock, never expose this product to
rain or humidity.
WARNING! To prevent electric shock hazard, do not connect to mains power supply while grille is
removed.
WARNING! to reduce the risk of electric shock, do not disassemble this product unless you are qualified.
Refer servicing to qualified service personnel.
CORRECT DISPOSAL OF THIS PRODUCT
This product should be handed over to an authorized collection site for recycling waste electrical and electronic equipment
(EEE). Improper handling of this type of waste could have a possible negative impact on the environment and human health due to
potentially hazardous substances that are generally associated with EEE. At the same time, your cooperation in the correct disposal of
this product will contribute to the effective usage of natural resources. For more information about where you can drop off your waste
equipment for recycling, please contact your local city office, waste authority or your household waste disposal service.
CARE AND MAINTENANCE
To ensure a long-life service, this product should be used following these advices:
- If the product is intended to be set up outdoors, be sure it is under cover and protected to rain and moisture.
- If the product needs to be used in a cold environment, slowly warm up the voice coils by sending a low-level signal for about 15
minutes before sending high-power signals.
- Always use a dry cloth to clean the exterior surfaces of the product, and always do it when the power is turned off.
CAUTION: to avoid damaging the exterior finishes do not use cleaning solvents or abrasives.
WARNING! CAUTION! For powered speakers, do cleaning only when the power is turned off.
FCC NOTES
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules.
These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a
commercial environment. This equipment generates, uses, and can radiate radio frequency energy, and if it is not installed and used
in accordance with the instruction manual, it may cause harmful interference to radio communications. Operation of this equipment
8
RCF S.p.A. thanks you for purchasing this product, which has been designed to guarantee reliability and high
performance.
DESCRIPTION
IPS series includes two models of two-channel power amplifiers designed for professional use in touring racks and installed sound
systems.
The two models only differ in their rated power:
- IPS 5.0K delivers up to 2 x 2600 W into 4 Ω (bridged: 5200 W into 8 Ω);
- IPS 2.5K delivers up to 2 x 1250 W into 4 Ω (bridged: 2500 W into 8 Ω).
- IPS 1.5K delivers up to 2 x 750 W into 4 Ω (bridged: 1500 W into 8 Ω).
MAIN FEATURES
- Fast response and low distortion.
- Easy to configure in STEREO / PARALLEL (mono) / BRIDGE modes.
- Extensive protective circuits ensuring high reliability and operating safety.
- Variable speed cooling system.
- Front panel SIGNAL / CLIP / FAULT LED indicators.
- XLR input connectors.
- SPEAKON and BINDING POST output connectors
- Limiter on each channel.
UNPACKING, INSTALLATION AND COOLING
Check the carton box and its contents to see if there is any sign of damage (should the amplifier be damaged, immediately inform
your local distributor / dealer and the forwarder).
It is always advisable to keep the packing materials, even if the amplifier has arrived in good condition.
Input and output cables are not included.
Each amplifier needs 2 units of a standard 19” rack cabinet. Four holes for rack mounting are on the front panel ears. Rear mounting
ears give additional support.
The amplifier shall not be installed in a place with:
- too high temperature, dust or excessive humidity;
- fog machine outputs oriented towards the amplifier;
- exhaust air ventilators;
- permanent vibrations;
- high-intensity electromagnetic fields (due to transformers, transmitters, etc.).
9
FRONT PANEL
[1] POWER switch. Push to turn on/off the amplifier. Before switching the amplifier on, check all cables and turn fully counterclockwise
both channel level controls . [3]
[2] POWER LED. When lit, the amplifier is switched on.
[3] Controls (one per channel) to adjust the output level of the respective amplifier channel. Turn clockwise to increase the output
level (0 dB = max. level), turn counterclockwise to decrease.
If the amplifier is set to mode, use the channel A control only. BRIDGE
[4] FAULT LED (one per channel). When lit, it indicates the internal protection intervention (due to overload, short-circuit, thermal
drift, fault) and the respective channel is muted. As soon as the problem is solved, this LED will be turned off. When turning the
amplifier on, this LED stays lit for three seconds.
[5] CLIP LED (one per channel). It blinks when the signal level reaches the clipping point, causing the limiter intervention of the
respective channel. If it stays lit continuously, the input signal level is excessive.
[6] SIGNAL LED (one per channel). When lit, it indicates the signal presence (above –40 dBu) at the respective input.


Produkt Specifikationer

Mærke: RCF
Kategori: Modtager
Model: IPS 2.5K

Har du brug for hjælp?

Hvis du har brug for hjælp til RCF IPS 2.5K stil et spørgsmål nedenfor, og andre brugere vil svare dig




Modtager RCF Manualer

RCF

RCF IPS 2.5K Manual

5 August 2024
RCF

RCF XPS 16KD Manual

27 Juli 2024
RCF

RCF AM1122-N Manual

21 Juli 2024
RCF

RCF AM2080 Manual

21 Juli 2024
RCF

RCF AM2320 Manual

20 Juli 2024
RCF

RCF AM6021 Manual

19 Juli 2024
RCF

RCF AM6020 Manual

23 Februar 2024
RCF

RCF IPS 1.5K Manual

5 December 2023
RCF

RCF XPS 16K Manual

13 Oktober 2023
RCF

RCF IPS 5.0K Manual

30 Maj 2023

Modtager Manualer