Resideo Lyric Manual


Læs nedenfor 📖 manual på dansk for Resideo Lyric (2 sider) i kategorien Detektor. Denne guide var nyttig for 7 personer og blev bedømt med 4.5 stjerner i gennemsnit af 2 brugere

Side 1/2
Wi-Fi® Water Leak and
Freeze Detector
Quick Start Guide
1 Download the Lyric app
Search for Honeywell Lyric in the
App Store or Google Play.
After downloading, launch the app,
register (if necessary), go to , Menu
and then go to Add New Device.
2 Install batteries
The detector is powered by 3 AA batteries (included). Open
the battery cover on the detector and install the
batteries.
When replacing the cover, press firmly
around the edges to ensure a snug
fit.
Note: The cable sensor jack is NOT
for plugging in a power adaptor.
Doing so could damage the detector.
3 Connect
Pair and name your detector
1 Under Add New Device, select
Lyric Water Leak and Freeze
Detector.
Note: Make sure Bluetooth is enabled
on your mobile device.
2 Provide a location for your
detector. Press .NEXT
3 The detector will now pair with
the app.
Note: If you have more than one
detector, you will need to connect
each detector individually.
4 An audible alert will sound and
your detector’s LED will turn solid
blue to indicate your detector is
paired. Press .NEXT
5 Create a custom name for the
detector or select one from the
list. Press .NEXT
GET IT ON
Lyric
5 Placement
Place the bottom of your detector
flat on the floor or a surface.
For wall mounting, use the included
screw and hang the detector on the
bottom cover’s mounting keyhole.
Optional cable sensor
To install the optional cable sensor,
remove the sensor jack plug and insert the cable sensor.
Insert the sensor jack plug at the end the cable sensor.
Additional cable sensors (sold separately) can be
connected to extend the cable and increase water sensing
area.
The entire length of cable is an extended sensor. You can
hang the detector from the wall or place both the detector
and cable sensor on the floor.
Note: The cable sensor jack is NOT for
plugging in a power adaptor. Doing so
could damage the detector.
Common uses
Operation
Lyric app experience
Below are a few examples of the Lyric app screens you will see as you
use the Lyric Water Leak and Freeze Detector.
Reset
Use one end of a paperclip to press and hold into the reset hole
for 5 seconds to reset Wi-Fi, detector settings, and to re-start
Bluetooth pairing. The LED will blink blue.
Press and hold the paperclip into the reset hole for 15 seconds to
restore factory defaults. The LED will blink blue.
Status LED
The detector has an LED that gives device status.
LED Detector state
During installation
Blinking Blue Powering up and connecting to Bluetooth.
Solid Blue Paired with Bluetooth.
Blinking Green Connecting to Wi-Fi network.
Solid Green Has power, Wi-Fi connection, and is operating
normally.
Note: LED turns o after 5 minutes to preserve
battery life.
Solid Red Failed to connect to Wi-Fi.
During operation
Blinking Red Detected a leak.
In case of an alert
To preserve battery life, it can take up to 1minute for the detector
to sense a leak.
You can mute the detector by pressing the Mute button in the app
or removing the batteries or cable sensor from the detector. The
mute command may take up to 1minute to reach the detector.
After the alert, wipe dry the detector and cable sensor and put
them back in place. Replace batteries if they were removed.
FCC Regulations
§ 15.19 (a)(3)
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1)
This device may not cause harmful interference, and (2) this device must accept any interference received,
including interference that may cause undesired operation.
§ 15.21
Changes or modifications not expressly approved by the party responsible for compliance could void the
user‘s authority to operate the equipment.
FCC Radiation Exposure Statement:
This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This
equipment should be installed and operated with minimum distance 20cm between the radiator & your
body.
IC Regulations
This device complies with Industry Canada license-exempt RSS standard(s). Operation is subject to the
following two conditions:
(1) this device may not cause interference, and
(2) this device must accept any interference, including interference that may cause undesired operation of
the device.
IC Radiation Exposure Statement:
This equipment complies with IC RSS-102 radiation exposure limits set forth for an uncontrolled
environment. This equipment should be installed and operated with minimum distance 20cm between the
radiator & your body.
Wi-Fi® is a registered trademark of Wi-Fi Alliance®
Connect to Wi-Fi
1 Choose your network from the
list. Press .NEXT
2 Enter your Wi-Fi password, if
necessary. Press .NEXT
3 When connected to Wi-Fi,
the LED will turn solid green
for 5minutes, then turn o to
preserve battery life.
Note: If you remove and replace
the detector’s batteries, it will reconnect to your Wi-Fi network
automatically.
4 Configure
Continue to follow instructions in the app to configure
your detector. Set the high and low levels for humidity
and temperature warnings, and identify the people
you want notified in case of an alarm. These settings
can be updated at any time using the app.
Need help?
Web: lyric.honeywell.com
MyLyric@honeywell.comEmail:
1-800-633-3991Phone:
Automation and Control Solutions
Honeywell International Inc.
1985 Douglas Drive North
Golden Valley, MN 55422
lyric.honeywell.com
® U.S. Registered Trademark.
© 2015 Honeywell International Inc.
09-15 Printed in U.S.A.
33-00097EF-01
Sensors
Mounting
keyhole
Cable
sensor jack
Sensor jack
plug
Cable
sensor jack
Leak detected
by device
30 day rolling
temperature trends
Low temperature
detected by device
WiFi connection
failure


Produkt Specifikationer

Mærke: Resideo
Kategori: Detektor
Model: Lyric

Har du brug for hjælp?

Hvis du har brug for hjælp til Resideo Lyric stil et spørgsmål nedenfor, og andre brugere vil svare dig




Detektor Resideo Manualer

Resideo

Resideo Lyric Manual

27 August 2024

Detektor Manualer

Nyeste Detektor Manualer

Optex

Optex SIP-5 Manual

21 December 2024
Protector

Protector WA-5.1 Manual

21 December 2024
Steinberg

Steinberg SBS-MD-9 Manual

16 December 2024
Steinberg

Steinberg SBS-MD-7 Manual

16 December 2024
Steinberg

Steinberg SBS-MD-2 Manual

16 December 2024
Steinberg

Steinberg SBS-MD-5 Manual

16 December 2024
Steinberg

Steinberg SBS-MD-3 Manual

15 December 2024
Steinberg

Steinberg SBS-MD-13 Manual

15 December 2024
Steinberg

Steinberg SBS-MD-6 Manual

15 December 2024