VA-3 MIDI Implementation
1
VA-3 MIDI Implementation
The VA-3 implements additional functionality and parameters over and above the
G-1000, which itself was an expansion of the GS sound generator format. These func-
tions and parameters are marked by a [VA-3] symbol. If MIDI messages marked by a
VA-3 symbol are transmitted to another GS format sound generator or to the G-1000,
those messages may not be recognized.
1. Receive data
Channel Voice Messages
Note off
For Drum Parts, these messages are received when Rx.NOTE OFF = ON for each
Instrument.
The velocity values of Note O messages are ignored.
Note on
Not received when Rx.NOTE MESSAGE = OFF. (Initial value is ON)
For Drum Parts, these messages are not received when Rx.NOTE ON = OFF for
each Instrument.
Polyphonic Key Pressure
Not received when Rx.POLY PRESSURE (PAf) = OFF. (Initial value is ON)
The resulting eect is determined by System Exclusive messages. With the initial
settings, there will be no eect.
Control Change
When Rx.CONTROL CHANGE = OFF, all control change messages except for
Channel Mode messages will be ignored.
The value specied by a Control Change message will not be reset even by a Pro-
gram Change, etc.
Bank Select (Controller number 0, 32)
Not received when Rx.BANK SELECT = OFF.
“Rx.BANK SELECT” is set to OFF by “GM1 System On,” and Bank Select messages
will be ignored.
Rx.BANK SELECT is set to ON by “GM2 System On.”
Rx.BANK SELECT is set to ON by power-on reset or by receiving “GS Reset.”
When Rx.BANK SELECT LSB = OFF, Bank number LSB (llH) will be handled as 00H
regardless of the received value. However, when sending Bank Select messages,
you have to send both the MSB (mmH) and LSB (llH, the value should be 00H) to-
gether.
Bank Select processing will be suspended until a Program Change message is re-
ceived.
The GS format “Variation number” is the value of the Bank Select MSB (Controller
number 0) expressed in decimal.
The VA-3 recognizes the Bank Select LSB (Controller number 32) as a ag for
switching between the VA-3 MAP, the G-1000 MAP, the G-800 MAP, and the SC-55
MAP. With a LSB of 01H, the SC-55 MAP and with a LSB of 02H, the G-800 MAP,
and with a LSB of 03H, the G-1000 MAP, and with a LSB of 04H, the VA-3 MAP will
be selected respectively.
Some other GS devices do not recognize the Bank Select LSB (Controller number
32).
Modulation (Controller number 1)
Not received when Rx.MODULATION = OFF (Initial value is ON)
The resulting eect is determined by System Exclusive messages. With the initial
settings, this is Pitch Modulation Depth.
Portamento Time (Controller number 5)
This adjusts the rate of pitch change when Portamento is ON or when using the Por-
tamento Control. A value of 0 results in the fastest change.
Data Entry (Controller number 6, 38)
Volume (Controller number 7)
Volume messages are used to adjust the volume balance of each Part.
Not received when Rx.VOLUME = OFF. (Initial value is ON)
Pan (Controller number 10)
The stereo position can be adjusted over 127 steps.
For Rhythm Parts, this is a relative adjustment of each Instrument’s pan setting.
Not received when Rx.PANPOT = OFF. (Initial value is ON)
Expression (Controller number 11)
This adjusts the volume of a Part. It can be used independently from Volume mes-
sages. Expression messages are used for musical expression within a performance;
e.g., expression pedal movements, crescendo and decrescendo.
Not received when Rx.EXPRESSION = OFF. (Initial value is ON)
Hold 1 (Controller number 64)
Not received when Rx.HOLD1 = OFF. (Initial value is ON)
Portamento (Controller number 65)
Not received when Rx.PORTAMENTO = OFF. (Initial value is ON)
Sostenuto (Controller number 66)
Not received when Rx.SOSTENUTO = OFF. (Initial value is ON)
Soft (Controller number 67)
Not received when Rx.SOFT = OFF. (Initial value is ON)
Filter Resonance (Timbre/Harmonic Intensity) (Controller number 71) [VA-3]
Status 2nd byte 3rd byte
8nH kkH vvH
9nH kkH 00H
n = MIDI channel number: 0H~FH (Ch.1~16)
kk = note number: 00H~7FH (0~127)
vv = note o velocity: 00H~7FH (0~127)
Status 2nd byte 3rd byte
9nH kkH vvH
n = MIDI channel number: 0H~FH (Ch.1~16)
kk = note number: 00H~7FH (0~127)
vv = note on velocity: 01H~7FH (1~127)
Status 2nd byte 3rd byte
AnH kkH vvH
n = MIDI channel number: 0H~FH (Ch.1~16)
kk = note number: 00H~7FH (0~127)
vv = key pressure: 00H~7FH (0~127)
Status 2nd byte 3rd byte
BnH 00H mmH
BnH 20H llH
n = MIDI channel number: 0H~FH (Ch.1~16)
mm = Bank number MSB: 00H~7FH (GS Variation number 0~127)
Initial value = 00H
ll = Bank number LSB: 00H~04H (MAP), Initial value = 00H
Status 2nd byte 3rd byte
BnH 01H vvH
n = MIDI channel number: 0H~FH (Ch.1~16)
vv = Modulation depth: 00H~7FH (0~127)
Status 2nd byte 3rd byte
BnH 05H vvH
n = MIDI channel number: 0H~FH (Ch.1~16)
vv = Portamento Time: 00H~7FH (0~127), Initial value = 00H (0)
Status 2nd byte 3rd byte
BnH 06H mmH
BnH 26H llH
n = MIDI channel number: 0H~FH (Ch.1~16)
mm, ll = the value of the parameter specied by RPN/NRPN
mm = MSB, ll = LSB
Status 2nd byte 3rd byte
BnH 07H vvH
n = MIDI channel number: 0H~FH (Ch.1~16)
vv = Volume: 00H~7FH (0~127), Initial value = 64H (100)
Status 2nd byte 3rd byte
BnH 0AH vvH
n = MIDI channel number: 0H~FH (Ch.1~16)
vv = pan: 00H~40H~7FH (Left~Center~Right),
Initial value = 40H (Center)
Status 2nd byte 3rd byte
BnH 0BH vvH
n = MIDI channel number: 0H~FH (Ch.1~16)
vv = Expression: 00H~7FH (0~127), Initial value = 7FH (127)
Status 2nd byte 3rd byte
BnH 40H vvH
n = MIDI channel number: 0H~FH (Ch.1~16)
vv = Control value: 00H~7FH (0~127)
Status 2nd byte 3rd byte
BnH 41H vvH
n = MIDI channel number: 0H~FH (Ch.1~16)
vv = Control value: 00H~7FH (0~127) 0~63 = OFF, 64~127 = ON
Status 2nd byte 3rd byte
BnH 42H vvH
n = MIDI channel number: 0H~FH (Ch.1~16)
vv = Control value: 00H~7FH (0~127) 0~63 = OFF, 64~127 = ON
Status 2nd byte 3rd byte
BnH 43H vvH
n = MIDI channel number: 0H~FH (Ch.1~16)
vv = Control value: 00H~7FH (0~127) 0~63 = OFF, 64~127 = ON
Status 2nd byte 3rd byte
BnH 47H vvH
n = MIDI channel number: 0H~FH (Ch.1~16)
vv= Resonance value (relative
change):
00H~7FH (-64~0~+63),
Initial value = 40H (no change)


Produkt Specifikationer

Mærke: Roland
Kategori: Ikke kategoriseret
Model: VA-3

Har du brug for hjælp?

Hvis du har brug for hjælp til Roland VA-3 stil et spørgsmål nedenfor, og andre brugere vil svare dig




Ikke kategoriseret Roland Manualer

Roland

Roland PDQ-8 Manual

22 December 2024
Roland

Roland CYQ-12 Manual

21 December 2024
Roland

Roland PDQ-8S Manual

21 December 2024
Roland

Roland EARTH Piano Manual

19 December 2024
Roland

Roland PD-9 Manual

10 December 2024
Roland

Roland FRP-NUVOLA Manual

10 December 2024
Roland

Roland P-6 Manual

10 December 2024
Roland

Roland MDS-12 Manual

9 December 2024
Roland

Roland PM-10 Manual

9 December 2024
Roland

Roland PD-14DSX Manual

9 December 2024

Ikke kategoriseret Manualer

Nyeste Ikke kategoriseret Manualer

Atlona

Atlona AT-DVIF30S-IR Manual

29 December 2024
Atlona

Atlona AT-PRO3HD66M Manual

29 December 2024
Atlona

Atlona AT-3GSDI500 Manual

29 December 2024
BlueBuilt

BlueBuilt BBMAG2M Manual

29 December 2024
Atlona

Atlona AT-3GSDI-14 Manual

28 December 2024
Atlona

Atlona AT-COMP10SS Manual

28 December 2024
Atlona

Atlona AT-2VGA300SL Manual

28 December 2024
Atlona

Atlona AT-HD-V216 Manual

28 December 2024
Atlona

Atlona AT-VGA11S Manual

28 December 2024
True

True TC900 Manual

28 December 2024