Sauter FA 10 Manual


Læs nedenfor 📖 manual på dansk for Sauter FA 10 (5 sider) i kategorien Ikke kategoriseret. Denne guide var nyttig for 3 personer og blev bedømt med 4.5 stjerner i gennemsnit af 2 brugere

Side 1/5
Instruction Manual
FA
JO, 05.07.2007 FA englisch.doc Page 1 of 3
SAUTER GmbH
Schumannstr. 33, D-72458 Albstadt
Tel: +49 (0) 7431 938 666
Albert-Sauter@sauter.eu
www.sauter.eu
Thank you for buying a SAUTER force gauge. We hope
you are pleased with your high quality force gauge with its
big functional range. If you have any queries, wishes or
helpful suggestions, do not hesitate to call our service
number.
1. Included in Delivery
- SAUTER FA
- Case
- Standard Attachments
2. Warning
2.1 Intended use
The instrument you have acquired serves to determine the
measuring value of the material to be measured. It is
intended to be used as a “non-automatic“ instrument, i.e.
the material to be measured is manually and carefully
attached at the instrument. The measuring value can be
read off after a stable measuring value has been obtained.
2.2 Inappropriate use
Do not use the instrument for dynamic measuring. In the
event that small quantities are removed or added to the
material to be
measured, incorrect measuring results can be displayed
due to the “stability compensation“ in the instrument.
(Example: Slow draining
off of liquid from a container suspended from the
instrument). Do not attach a continuous load. This can
damage the measuring
unit as well as the parts, relevant to safety.
Prevent jolts, torsion and oscillation (e.g. by appending
slopingly) of all kinds. Be sure to prevent overloading the
instrument in excess of the stated maximum load (max.),
minus any tare weight that may possibly exist. This could
damage the instrument (risk of breakage).
Important:
• Always make sure that there are no people or materials
below the load that could be injured or damaged!
• The instrument is not suitable for measuring people. Do
not use as baby scales!
• The instrument does not comply with the medical product
law (MPG).
Never operate the instrument in hazardous locations. The
series design is not explosion-proof. Structural alterations
may not be
made to the instrument. This can lead to incorrect
measuring results, faults concerning safety regulations as
well as to destruction
of the instrument. The instrument may only be used in
compliance with the described guidelines. Varying areas of
application/
planned use must be approved by SAUTER in writing.
2.3 Guarantee
The guarantee is not valid following
• non-observation of our guidelines in the operating
instructions
• use outside the described applications
• alteration to or opening of the device
Indicator Dial
Finger
Knob
Controller
Track /
Peak
Central Stick
Force
Direction
Force
Direction


Produkt Specifikationer

Mærke: Sauter
Kategori: Ikke kategoriseret
Model: FA 10

Har du brug for hjælp?

Hvis du har brug for hjælp til Sauter FA 10 stil et spørgsmål nedenfor, og andre brugere vil svare dig




Ikke kategoriseret Sauter Manualer

Sauter

Sauter FK 10 Manual

11 August 2024
Sauter

Sauter FA 200 Manual

6 August 2024
Sauter

Sauter FK 500 Manual

6 August 2024
Sauter

Sauter FK 1K Manual

5 August 2024
Sauter

Sauter FA 10 Manual

3 August 2024
Sauter

Sauter FL 200 Manual

3 August 2024
Sauter

Sauter FL 500 Manual

3 August 2024
Sauter

Sauter FL 100 Manual

3 August 2024
Sauter

Sauter FL 50 Manual

1 August 2024
Sauter

Sauter FK 100 Manual

1 August 2024

Ikke kategoriseret Manualer

Nyeste Ikke kategoriseret Manualer