Schneider MTN663991 Manual

Schneider Termostat MTN663991

Læs nedenfor 📖 manual på dansk for Schneider MTN663991 (1 sider) i kategorien Termostat. Denne guide var nyttig for 36 personer og blev bedømt med 4.5 stjerner i gennemsnit af 2 brugere

Side 1/1
GB
¼
DANGER
Risk of fatal injury due to electrical current.
All work on the device should only be carried out
by skilled electrician. Observe the country-
specific regulations as well as the valid KNX
guidelines.
The KNX brightness and temperature sensor (referred
to as sensor in the following) is suitable for brightness
and temperature measurement in KNX building system
technology. The measured values are sent to the bus.
Measurement range for brightness measurement:
1 to 100,000 lux (± 20% or ± 5Lux)
Measurement range for temperature measurement:
-25°C to +5C 5% or ± 1 degree)
|The larger tolerances are applicable for
brightness and temperature measurement.
AProgramming LED
BProgramming button
CBus connecting terminal
For your safety
Getting to know the sensor
Connections, displays and operating
elements
AB
C
¼
WARNING
Risk of fatal injury from electrical current.
The device could become damaged.
Safety clearance must be guaranteed in
accordance with IEC 60664-1. There must be at
least 4 mm between the individual cores of the
230 V supply cable and the KNX cable.
½CAUTION
The device could become damaged.
Moisture and dirt can penetrate the housing. This
can result in device failure and a short circuit on
the bus line. Always install the device vertically
with the screw fitting facing downwards.
1Fix the sensor.
2Aligne the sensor.
How to install the sensor
230 V
4 mm
KNX
6 mm 14 mm
25 mm
1Push the bus cable through the gasket into the
terminal compartment.
|Observe the correct polarity during connection.
2Connect KNX.
3Connect the bus voltage.
The LED flashes.
1Press the programming button.
The programming LED lights up.
2Load the physical address and application into the
device from the ETS.
The programming LED goes out.
The application has been loaded successfully, the
device is operative.
|When the device is operative, the LED stops
flashing approximately 10 seconds after
connecting the bus voltage or after loading the
application. Otherwise an invalid application
program has been loaded.
Cover installation:
1Carefully fit the cover on the installed device.
2Screw on the cover.
Cover care:
Clean the cover at regular intervals so that dirt does not
generate inaccurate brightness measurement values.
|Use a damp cloth for cleaning.
If you have technical questions, please contact the
Customer Care Center in your country.
www.schneider-electric.com
This product must be installed, connected and used in
compliance with prevailing standards and/or installa-
tion regulations. As standards, specifications and de-
signs develop from time to time, always ask for
confirmation of the information given in this publica-
tion.
Schneider Electric Industries SAS
How to connect the sensor
How to operate the sensor
How to installation and care the cover
Technical data
KNX: DC 24 V
Measurement range
Temperature: -25°C to +55°C
(± 5 % or ± 1 degree)
Brightness: 1 to 100,000 lux
(± 20 % or ± 5 lux)
Power consumption: < 150 mW
Type of protection
when installed:
IP 54 when installed vertically
with cover
KNX brightness and temperature sensor
Operating instructions
Art. no. MTN663991
V6639-562-00 03/08


Produkt Specifikationer

Mærke: Schneider
Kategori: Termostat
Model: MTN663991

Har du brug for hjælp?

Hvis du har brug for hjælp til Schneider MTN663991 stil et spørgsmål nedenfor, og andre brugere vil svare dig




Termostat Schneider Manualer

Termostat Manualer

Nyeste Termostat Manualer