Seco-Larm E-942FC-1K3SQ Manual


Læs nedenfor 📖 manual på dansk for Seco-Larm E-942FC-1K3SQ (2 sider) i kategorien Ikke kategoriseret. Denne guide var nyttig for 22 personer og blev bedømt med 4.5 stjerner i gennemsnit af 2 brugere

Side 1/2
Magnetic Gate Lock Bracket Installation Manual
SECO-LARM U.S.A., Inc.
NOTICE: The information and specifications printed in this manual are current at the time of publication. However,
the SECO-LARM policy is one of continual development and improvement. For this reason, SECO-LARM reserves the
right to change specifications without notice. SECO-LARM is also not responsible for misprints or typographical errors.
Copyright © 2011 SECO-LARM U.S.A., Inc. All rights reserved. This material may not be reproduced or copied, in whole
or in part, without the written permission of SECO-LARM.
REGULAR MAINTENANCE
Clean the contact surfaces of the electromagnet or armature plate with a soft cloth and non-abrasive, non-corrosive cleaner.
Apply a light coat of a silicon lubricant to both contact surfaces and wipe away the excess to prevent rust.
Check that the armature plate is securely attached to the bracket, yet can pivot slightly around the armature screw.
Check that the electromagnet is securely attached to the bracket.
TROUBLESHOOTING
Possible cause:
No power
Poor contact between
electromagnet and
armature plate
Incorrect voltage setting
A secondary diode was
installed across the
electromagnet
Solutions:
Check to make sure the wires are secure
Check that the power supply is
connected and operating
Make sure the unit is wired correctly
Make sure the electromagnet and
armature plate are properly aligned
Make sure the contact surfaces of the
electromagnet and armature plate are
clean and free from rust
Check the power leads with a meter, and
make sure the correct voltage is present
The electromagnet is fitted with a metal
oxide varistor to prevent interference, so
do not install a secondary diode
Problem:
Gate does not lock
Gate locks, but can be
easily forced open
Delay in gate releasing
For most types of outdoor sliding and swinging electric gates.
Includes a magnetic lock with brackets for armature and magnet.
Brackets can be welded or bolted directly to gate.
Holding force: E-942FC-1K3SQ 1,300 pounds (591kg).
E-942FC-600SQ 600 pounds (272kg).
Brackets are zinc-plated for corrosion resistance.
Brackets have black finish to match most gates.
Water- and vandal-resistant attractive stainless-steel finish.
Maintenance-free, factory-sealed design.
Fail-safe operation (unlocks door if power is removed).
Mounted vertically.
Four knockouts on the junction box.
Adapter and mounting hardware included.
Voltage
12VDC or 24VDC. Prewired for 12VDC operation.
Current draw
500mA @ 12VDC (250mA @ 24VDC).
MOUNTING THE ELECTROMAGNETIC LOCK
A. Determine type of gate:
1. Single-swing gate — Gate swings on one end, and comes to rest on a fixed gate post when closed. In this
case, a
typical installation has the electromagnet fixed to the gate post, and the armature connected to the free end
of the gate.
2. Double-swing gateTwo gates swing in the same direction when activated. The electromagnet is fixed to
the free end of one gate, and the armature is fixed to the free end of the other.
3. Sliding gate — The gate slides instead of swings away from a fixed gate post. A typical installation has the
electromagnet fixed to the gate post, and armature connected to the free end of the gate.
B. Mount the electromagnet — In most cases, the position of the electromagnet will determine the location of the
armature plate. Make sure there is space to run the cable.
1. Tack weld bracket into place. (Tack weld only.)
2. Dismount the electromagnetic lock from the bracket. Warning: Failure to remove electromagnetic lock will
result in severe damage to lock. Weld 3 or 4 beads about 1” apart. Make sure not to weld the junction box.
(See diagram for “No Weld” areas.)
3. Remount the electromagnetic lock.
SECO-LARM® U.S.A., Inc.
16842 Millikan Avenue, Irvine, CA 92606
Tel: 800-662-0800 / 949-261-2999 Fax: 949-261-7326
Website: www.seco-larm.com
E-mail: sales
@
seco-larm.com
UL CERTIFICATION
Electromagnetic lock only (Model E-942FC-1300/E-942FC-600) conforms to UL/10B
“Fire Tests of Door Assemblies” and UL/10C Positive Pressure Fire Tests of Door Assemblies” for swinging door assemblies.
It is also classified in accordance with the Uniform Building Code standard 7-2.
Page 1
(Magnetic lock only)
Page 4


Produkt Specifikationer

Mærke: Seco-Larm
Kategori: Ikke kategoriseret
Model: E-942FC-1K3SQ

Har du brug for hjælp?

Hvis du har brug for hjælp til Seco-Larm E-942FC-1K3SQ stil et spørgsmål nedenfor, og andre brugere vil svare dig




Ikke kategoriseret Seco-Larm Manualer

Ikke kategoriseret Manualer

Nyeste Ikke kategoriseret Manualer

Smeg

Smeg KIT6PX Manual

23 December 2024
Smeg

Smeg KIT6CX Manual

23 December 2024
Smeg

Smeg GTA-6 Manual

23 December 2024