Specifications:
Dimensions:
Sample Application:
Loop type
Open loop
Electrical configuration
N.O.
Operating voltage
5~24 VDC
Current
draw (max.)
12VDC
30mA
24VDC
50mA
Wire
6ft (1.8m) 2C (22AWG)
Case
Color
White
Material
ABS
Operating temperature
32°~140° F (0°~60° C)
Dimensions
2
1
/
2
"x
1
/
2
"x
1
/
2
" (64x13x13 mm)
Weight
1.6-oz (44g)
SSW
-
113H
Water Sensor
Manual
®
PICNN1
MI_SSW
-
113H_171006.docx
SECO-LARM
®
U.S.A., Inc.
16842 Millikan Avenue, Irvine, CA 92606
Website:
www.seco
-
larm.com
Phone: (949) 261
-
2999 | (800) 662
-
0800
Email: sales@seco
-
larm.com
WARRANTY:
This SECO
-
LARM product is warranted against defects in material and workmanship while used in normal service
for two (2) years from the date of sale to the original customer.
NOTICE:
The SECO
-
LARM policy is one of continual development and improveme
nt. For that reason, SECO
-
LARM reserves the
right to change specifications without notice. SECO-
LARM is also not responsible for misprints. All trademarks are the property of
SECO
-
LARM
U.S.A.,
Inc. or their respective owners. Copyright
©
2017 SECO
-
LARM
U.S
.A.,
Inc. All rights reserved.
Install anywhere water damage may occur
Detects conductive, non-flammable liquids
For open loop circuits
Automatic reset
Relay Module
9~16 VDC
Power Supply
+
-
NO
NC
COM
SL-1301-SAQ
Trigger
SSW-113H
SR
-
1212
-
C2ALQ
Top View
1
/
2
"
(13mm)
2
1
/
2
"
(64mm)
6ft
(1.8m)
Front View
1
/
2
"
(13mm)
1
/
4
"
(6
mm)
2x
Water Sensor
4x
Screws
1x
Manual
Parts List:
NOTE:
Connect Water Sensor to an alarm control panel
or relay module.
Do not wire directly to siren,
strobe, etc.
After
installation, test unit with damp sponge or paper. Inspect annually and replace if there is any corrosion or damage.
Alarm
Control Panel
Relay Module
Alarm Control
Panel
Trigger
SSW-113H
EOL Resistor
*
If
the panel uses an EOL resistor
(not
included
)
,
then 6VDC
is the minimum requirement.
Features:
2PCS


Produkt Specifikationer

Mærke: Seco-Larm
Kategori: Detector
Model: SSW-113H

Har du brug for hjælp?

Hvis du har brug for hjælp til Seco-Larm SSW-113H stil et spørgsmål nedenfor, og andre brugere vil svare dig




Detector Seco-Larm Manualer

Seco-Larm

Seco-Larm SSW-113H Manual

29 August 2024

Detector Manualer

Nyeste Detector Manualer

DSC

DSC RM-2 Manual

13 September 2024
K40

K40 Platinum200 Expert Manual

11 September 2024
K40

K40 Platinum360 Expert Manual

11 September 2024
Noyafa

Noyafa NF-820 Manual

6 September 2024
Soler & Palau

Soler & Palau CPTA Manual

6 September 2024
ORNO

ORNO OR-DC-633 Manual

5 September 2024
STI

STI -8201-W Manual

5 September 2024
STI

STI -9623 Manual

5 September 2024
STI

STI -9620 Manual

5 September 2024
STI

STI -8100 Manual

5 September 2024