TCP ID0 BI0 0SE 023097D4 280114
ADJUSTABLE PLATES
Brand Model Support Notches to break Side hole-cover adaptors
BTICINO
®
light A 2 no
light tech A 2 no
Living International A 2 no
Matix A 2 Width 2.5 mm
Luna B 3 no
Axolute B 3 no
VIMAR
®
Idea A 1 Width 4 mm
Idea Rondò A 1 Width 4 mm
Plana B 3 no
Eikon B 3 no
GEWISS
®
Playbus A 2 Width 4 mm
Playbus Young A 2 Width 4 mm
Chorus B 3 no
AVE
®
Banquise A none Width 4 mm
Sistema 45 A none Width 4 mm
Noir A none Width 4 mm
SIEMENS
®
Delta Futura A 2 Width 4 mm
LEGRAND
®
Ergo A 2 no
Cross A 2 no
Vela A 2 no
MASTER
®
Modo B none no
Mix B none no
PLATE SUPPORT
The timer thermostat was specifically studied to fit many of the finishing plates present on the market.
Choose support A or B depending on the type of finishing plate used. If necessary, intervene on the support as described
hereafter.
BTICINO
®
, VIMAR
®
, GEWISS
®
, AVE
®
, SIEMENS
®
, LEGRAND
®
, MASTER
®
are brands registered by their legitimate
owners.
SUPPORT B
3
3
3
3
SUPPORT A
1
2
2
1
2
2
1
1
2 2
Side adaptor
insertion
4
TCP ID0 BI0 0SE 023097A4 280114
FREETIME
cccc
Code TCP ID0 BI- 0SE
RECESSED DAILY DIGITAL CHRONOSTAT
Possibility of setting room temperature at two levels
(Comfort and Economy)
Ample backlit display
Dip-Switches on front to program the time
Possibility of Manual mode
Possibility of Offset adjustment
Possibility of Antifreeze temperature adjustment
Buttons for digital setting of Comfort and Economy temperatures
Shutdown with Antifreeze function not deactivated
Fixing on 503 box (3-module recessed box)
Via Prosdocimo, 30
I-36061 BASSANO DEL GRAPPA (VI)
Tel.: +39.0424.567842
Fax.: +39.0424.567849
http://www.seitron.it
e-mail: info@seitron.it
s
e
i
t
r
o
n
Fig. 2: Assembly layout.
BATTERY COMPARTMENT
Fig. 1: Outward appearance.
MANUAL
BUTTON
ON / OFF BUTTON
TIME/TEMPERATURE
BUTTON
RESET
BUTTON
TAB
SWITCHES FOR SETTING THE COMFORT/ECONOMY MODE
Interval 0 .. 5 Interval 9 .. 10 Interval 6 .. 6.30
OK BUTTON
COMFORT TEMPERATURE
INCREASE BUTTON
ECONOMY TEMPERATURE
INCREASE BUTTON
1
Fig. 3: Wiring diagram
N
L
LOAD
765
LOAD
7 8 9


Produkt Specifikationer

Mærke: Seitron
Kategori: Termostat
Model: TCP ID0 BI-0SE Freetime

Har du brug for hjælp?

Hvis du har brug for hjælp til Seitron TCP ID0 BI-0SE Freetime stil et spørgsmål nedenfor, og andre brugere vil svare dig




Termostat Seitron Manualer

Seitron

Seitron TAS022 Manual

31 August 2024
Seitron

Seitron TAEKR02C Manual

31 August 2024
Seitron

Seitron TAEZN42C Manual

31 August 2024
Seitron

Seitron TPER00MI Manual

31 August 2024
Seitron

Seitron TCEGIOBI03 Manual

31 Januar 2024
Seitron

Seitron TCW01B Manual

12 November 2023
Seitron

Seitron TAEDI4MC Manual

24 Oktober 2023
Seitron

Seitron TAD02B Manual

17 April 2023
Seitron

Seitron TCW02B Manual

19 Februar 2023

Termostat Manualer

Nyeste Termostat Manualer

ATTACK

ATTACK OT80 Manual

17 December 2024
Warmup

Warmup +Kit Manual

17 December 2024
Warmup

Warmup 5iE Manual

17 December 2024
EQ-3

EQ-3 HmIP-WTH-2 Manual

16 December 2024
EQ-3

EQ-3 HMIP-WTH Manual

16 December 2024
EQ-3

EQ-3 HMIP-eTRV Manual

16 December 2024