Siemens SITOP UPS1100 Manual
Siemens
Uafbrydelig strømforsyning (UPS)
SITOP UPS1100
Læs nedenfor 📖 manual på dansk for Siemens SITOP UPS1100 (2 sider) i kategorien Uafbrydelig strømforsyning (UPS). Denne guide var nyttig for 40 personer og blev bedømt med 4.5 stjerner i gennemsnit af 2 brugere
Side 1/2
© Siemens AG 2013. All rights reserved
C98130-A7623-A1-3-6419, 08.2013
SITOP UPS1100
SITOP UPS1100
SITOP UPS1100
SITOP UPS1100 SITOP UPS1100
Batteriemodul 1,2 Ah
Batteriemodul 1,2 Ah
Batteriemodul 1,2 Ah
Batteriemodul 1,2 Ah Batteriemodul 1,2 Ah
6EP4131-0GB00-0AY0
6EP4131-0GB00-0AY0
6EP4131-0GB00-0AY0
6EP4131-0GB00-0AY0 6EP4131-0GB00-0AY0
Batteriemodul 3,2 Ah
Batteriemodul 3,2 Ah
Batteriemodul 3,2 Ah
Batteriemodul 3,2 Ah Batteriemodul 3,2 Ah
6EP4133-0GB00-0AY0
6EP4133-0GB00-0AY0
6EP4133-0GB00-0AY0
6EP4133-0GB00-0AY0 6EP4133-0GB00-0AY0
Batteriemodul 7 Ah
Batteriemodul 7 Ah
Batteriemodul 7 Ah
Batteriemodul 7 Ah Batteriemodul 7 Ah
6EP4134-0GB00-0AY0
6EP4134-0GB00-0AY0
6EP4134-0GB00-0AY0
6EP4134-0GB00-0AY0 6EP4134-0GB00-0AY0
Operating Instructions (compact)
Bild 1: Ansicht Geräte
Figure 1: View of the devices
Figure 1: Vue des appareils
Figura 1: Vista degli apparecchi
Figura 1: Vista de aparatos
Bild 2: Montage 1,2 Ah
Figure 2: Mounting 1.2 Ah
Figure 2: Montage 1,2 Ah
Figura 2: Montaggio 1,2 Ah
Figura 2: Montaje 1,2 Ah
ENGLISH
ENGLISH
ENGLISH
ENGLISH ENGLISH
Description
Description
Description
Description Description
The 24 V/1.2 Ah, 3.2 Ah or 7 Ah battery
module has 2x maintenance-free, sealed
lead AGM rechargeable batteries as well
as terminals for the connecting cables to
the uninterruptible power supply SITOP
UPS1600.
degree of protection IP20 according to
EN 60529
See Figure 1 View of the devices (Page 1)
Safety notes
Safety notes
Safety notes
Safety notesSafety notes
NOTICE
NOTICE
NOTICE
NOTICE NOTICE
The fuses should only be inserted in the
fuse holder when commissioning the
device.
When replacing the rechargeable
batteries, always use batteries with the
same batch number. (approximately the
same charge state).
The rechargeable batteries must be
disposed of, discharged according to the
applicable regulations.
When storing, installing and operating
the buffer batteries, the regulations of
VDE 0510 Part 2 / EN 50272-2 or the
applicable national regulations must be
complied with.
It must be ensured that the battery
location is suitably ventilated.
Location of the battery module: In the
lower part of the control cabinet or at the
coolest location in the control cabinet.
Only qualified personnel are allowed to
install the device/system and set it into
operation.
Assembling
Assembling
Assembling
Assembling Assembling
Direct wall mounting
or
DIN EN 60715-TH35-15/7,5 for 1.2 Ah
or
DIN EN 60715-TH35-15 for 3.2 Ah
The device must be mounted in such a
way that the input and output terminals
are at the bottom.
A clearance of at least 50 mm must be
maintained above and below the device.
See Figure 2 Mounti 1) ng 1.2 Ah (Page
See Figure 3 Mounti 2) ng 3.2 Ah (Page
See Figure 4 Mounti 2) ng 7 Ah (Page
Bild 3: Montage 3,2 Ah
Figure 3: Mounting 3.2 Ah
Figure 3: Montage 3,2 Ah
Figura 3: Montaggio 3,2 Ah
Figura 3: Montaje 3,2 Ah
Bild 4: Montage 7 Ah
Figure 4: Mounting 7 Ah
Figure 4: Montage 7 Ah
Figura 4: Montaggio 7 Ah
Figura 4: Montaje 7 Ah
Bild 5: Input/Output 1,2 Ah
Figure 5: Input/output 1.2 Ah
Figure 5: Entrée/sortie 1,2 Ah
Figura 5: Input/Output 1,2 Ah
Figura 5: Entrada/salida 1,2 Ah
Connecting
Connecting
Connecting
Connecting Connecting
For installation of the devices, the
relevant country-specific regulations
must be observed.
See Figure 5 Input/output 1.2 Ah (Page 2)
See Figure 6 Input/output 7 Ah (Page 3)
See Figure 7 Terminal data 1.2 Ah/3.2 Ah
(Page 3)
See Figure 8 Terminal data 7 Ah (Page 3)
Structure
Structure
Structure
Structure Structure
①DC input X1
②Signal terminal X2
③Fuses F1/F2 (F2 only for 7 Ah)
④Signaling (LED)
⑥Screws for battery replacement
(Torx T10)
See Figure 5 Input/output 1.2 Ah (Page 2)
See Figure 6 Input/output 7 Ah (Page 3)
Battery
Battery
Battery
Battery Battery
2x maintenance-free lead AGM
rechargeable batteries
12 V/1.2 Ah: Type: YUASA NP1.2-12
12 V/3.2 Ah: Type: YUASA NP3.2-12 or
B.B.Battery BP3.6-12
12 V/7 Ah: Type: YUASA NP7-12 or
B.B.Battery BP7-12
Battery replacement
● Remove the fuse
● Release the screws ⑥, open the
cover
● on for at least 2sPress the reset butt
(LED flashes)
● Replacing the battery
● on for at least 2sPress the reset butt
● Close the cover (screw)
● Insert the fuse
See Figure 9 Reset (Page 3)
See Figure 10 Wiring schematic
(Page 4)
The self-discharge rates of the
rechargeable batteries is approx.
3%/month for a temperature of 20 °C.
This value is temperature dependent,
and for an increasing temperature,
becomes more unfavorable and for a
decreasing temperature, more favorable.
Produkt Specifikationer
Mærke: | Siemens |
Kategori: | Uafbrydelig strømforsyning (UPS) |
Model: | SITOP UPS1100 |
Har du brug for hjælp?
Hvis du har brug for hjælp til Siemens SITOP UPS1100 stil et spørgsmål nedenfor, og andre brugere vil svare dig
Uafbrydelig strømforsyning (UPS) Siemens Manualer
12 Februar 2024
11 April 2023
Uafbrydelig strømforsyning (UPS) Manualer
- Uafbrydelig strømforsyning (UPS) Ikea
- Uafbrydelig strømforsyning (UPS) CyberPower
- Uafbrydelig strømforsyning (UPS) HP
- Uafbrydelig strømforsyning (UPS) GYS
- Uafbrydelig strømforsyning (UPS) Lenovo
- Uafbrydelig strømforsyning (UPS) Adj
- Uafbrydelig strømforsyning (UPS) Wago
- Uafbrydelig strømforsyning (UPS) Gembird
- Uafbrydelig strømforsyning (UPS) Tripp Lite
- Uafbrydelig strømforsyning (UPS) Digitus
- Uafbrydelig strømforsyning (UPS) Aiptek
- Uafbrydelig strømforsyning (UPS) EnerGenie
- Uafbrydelig strømforsyning (UPS) Voltcraft
- Uafbrydelig strømforsyning (UPS) APC
- Uafbrydelig strømforsyning (UPS) LevelOne
- Uafbrydelig strømforsyning (UPS) Eaton
- Uafbrydelig strømforsyning (UPS) BlueWalker
- Uafbrydelig strømforsyning (UPS) V7
- Uafbrydelig strømforsyning (UPS) Steren
- Uafbrydelig strømforsyning (UPS) Salicru
- Uafbrydelig strømforsyning (UPS) Approx
Nyeste Uafbrydelig strømforsyning (UPS) Manualer
15 November 2024
8 November 2024
8 November 2024
22 Oktober 2024
22 Oktober 2024
21 Oktober 2024
12 Oktober 2024
12 Oktober 2024
12 Oktober 2024
2 Oktober 2024