Side 1/1
SC-
33
S+
34
SC-
35
S+
36
5820 Board
Assembly
SLC Out SLC In
NC2
-SLC+
NC1 C1NO2C2 NO1
1 2 3 4 5 6 7 8
ON
Relay 1
Relay 2
Figure 1: Typical Wiring
Contacts are Form C,
non-supervised.
Power limited sources only.
Programmable relays.
This sheet is intended to be used for quick reference only. For complete information on wiring, addressing, and
programming this device, refer to the control panel installation manual.
P/N 151091 Rev D
If power-limited circuits are installed
(using types FPL, FPLR, FPLP or
other permitted substitute cables),
they must be separated from all
other conductors by a minimum of
0.25 in. or by a nonconductive
sleeve or barrier.
Model SD500-ARM Relay Module Installation Quick Reference
NC2
-SLC+
NC1 C1NO2C2 NO1
Fit screws through notches
on mounting plate. Tighten
screws to secure to box.
Figure 2: Typical Mounting
4-square electrical box
SD500-ARM circuit board
and mounting plate
(assembled at the factory)
Cover plate
45678
When attaching cover plate,
line up screw holes as shown.
Dipswitch
For device addressing.
See manual for list of
valid addresses.
LED
LED flashes green when
contacts are in normal state;
flashes red when
contacts are activated.
Supervised
Power limited
SILENT
KNIGHT
®
by Honeywell
30 VDC @ 2.0A Resistive
30 VDC @ 1.0 A Inductive (.6PF)
30 VDC @ 0.6 A (0.35PF) Pilot Duty
120 VAC @ 0.6 A (0.35PF) Pilot Duty
Operating Temperature
Operating Voltage
SLC Current
SLC Loop Resistance
Relay Ratings
For indoor use only
32° – 120°F (0° – 49°C)
24 VDC
0.55 mA
50W
Electrical & Environmental Specifications
Produkt Specifikationer
Mærke: | Silent Knight |
Kategori: | Detector |
Model: | SD500-ARM |
Har du brug for hjælp?
Hvis du har brug for hjælp til Silent Knight SD500-ARM stil et spørgsmål nedenfor, og andre brugere vil svare dig
Detector Silent Knight Manualer
30 August 2024
30 August 2024
30 August 2024
30 August 2024
30 August 2024
Detector Manualer
- Detector Hager
- Detector Silverline
- Detector Soler & Palau
- Detector Pyle
- Detector Nedis
- Detector Optex
- Detector Smartwares
- Detector Laserliner
- Detector Black And Decker
- Detector Dometic
- Detector Busch-Jaeger
- Detector Elro
- Detector Steinel
- Detector Powerfix
- Detector Maginon
- Detector Genie
- Detector National Geographic
- Detector Olympia
- Detector B/R/K
- Detector GEV
- Detector Testboy
- Detector Cobra
- Detector Velleman
- Detector JUNG
- Detector ORNO
- Detector Amprobe
- Detector Fluke
- Detector Hikvision
- Detector Testo
- Detector Evolveo
- Detector Vimar
- Detector Dahua Technology
- Detector ZKTeco
- Detector V-TAC
- Detector Schwaiger
- Detector Beha-Amprobe
- Detector Bearware
- Detector AngelEye
- Detector Royal Sovereign
- Detector Safescan
- Detector X4-Tech
- Detector DSC
- Detector Satel
- Detector Garrett
- Detector Kreator
- Detector Escort
- Detector Ebode
- Detector System Sensor
- Detector Thitronik
- Detector Fisher
- Detector SureCall
- Detector STI
- Detector Schabus
- Detector Zircon
- Detector BlendMount
- Detector K40
- Detector Gewiss
- Detector Seco-Larm
- Detector S.E. International
- Detector Rocky Mountain
- Detector Skyscan
- Detector Noyafa
Nyeste Detector Manualer
21 September 2024
13 September 2024
11 September 2024
11 September 2024
6 September 2024
6 September 2024
5 September 2024
5 September 2024
5 September 2024
5 September 2024