Sirius 3RV2011-0HA10 Manual

Sirius Afbryder 3RV2011-0HA10

Læs nedenfor 📖 manual på dansk for Sirius 3RV2011-0HA10 (8 sider) i kategorien Afbryder. Denne guide var nyttig for 33 personer og blev bedømt med 4.5 stjerner i gennemsnit af 2 brugere

Side 1/8
Data sheet
Data sheet
Data sheet
Data sheetData sheet 3RV2011-0HA10
3RV2011-0HA10
3RV2011-0HA10
3RV2011-0HA103RV2011-0HA10
Circuit breaker size S00 for motor protection, CLASS 10 A-release
0.55...0.8 A N-release 10 A screw terminal Standard switching
capacity
Product brand name
Product brand name
Product brand name
Product brand nameProduct brand name SIRIUS
Product designation
Product designation
Product designation
Product designationProduct designation Circuit breaker
Design of the product
Design of the product
Design of the product
Design of the productDesign of the product For motor protection
Product type designation
Product type designation
Product type designation
Product type designationProduct type designation 3RV2
General technical data
Size of the circuit-breaker
Size of the circuit-breaker
Size of the circuit-breaker
Size of the circuit-breakerSize of the circuit-breaker S00
Size of contactor can be combined company-specific
Size of contactor can be combined company-specific
Size of contactor can be combined company-specific
Size of contactor can be combined company-specificSize of contactor can be combined company-specific S00, S0
Product extension
Product extension
Product extension
Product extensionProduct extension
● Auxiliary switch Yes
Power loss [W] total typical
Power loss [W] total typical
Power loss [W] total typical
Power loss [W] total typicalPower loss [W] total typical 6W
Surge voltage resistance rated value
Surge voltage resistance rated value
Surge voltage resistance rated value
Surge voltage resistance rated valueSurge voltage resistance rated value 6kV
maximum permissible voltage for safe isolation
maximum permissible voltage for safe isolation
maximum permissible voltage for safe isolation
maximum permissible voltage for safe isolationmaximum permissible voltage for safe isolation
● in networks with grounded star point between
main and auxiliary circuit
400V
● in networks with grounded star point between
main and auxiliary circuit
400V
Protection class IP
Protection class IP
Protection class IP
Protection class IPProtection class IP
● on the front IP20
● of the terminal IP20
3RV2011-0HA10 Subject to change without notice
Page 1/
8
06/07/2019 © Copyright Siemens


Produkt Specifikationer

Mærke: Sirius
Kategori: Afbryder
Model: 3RV2011-0HA10

Har du brug for hjælp?

Hvis du har brug for hjælp til Sirius 3RV2011-0HA10 stil et spørgsmål nedenfor, og andre brugere vil svare dig




Afbryder Sirius Manualer

Sirius

Sirius 3RV2011-0HA10 Manual

20 November 2022

Afbryder Manualer

Nyeste Afbryder Manualer

ATen

ATen CE624-AT-G Manual

20 August 2024
Hager

Hager ADC913T Manual

22 Maj 2024
Hager

Hager LLD685 Manual

19 Maj 2024
Hager

Hager LLD004 Manual

17 Maj 2024
Hager

Hager LLK225 Manual

28 April 2024
Hager

Hager AEM440T Manual

26 April 2024
Hager

Hager LLG680 Manual

24 April 2024