Skylink 68 - remote Manual


Læs nedenfor 📖 manual på dansk for Skylink 68 - remote (2 sider) i kategorien Garagepoortopener. Denne guide var nyttig for 6 personer og blev bedømt med 4.5 stjerner i gennemsnit af 2 brugere

Side 1/2
Chamberlain®
Lift-Master®
Sears®
Wayne Dalton®
Master Mechanic®
Genie® (9 positions)
Genie® (12 positions)
Overhead Door®
Pulsar/Allister/Allstar®
Master Craft®
Linear®
M-O-M®
Stanley®
Multi-Code®
Skylink® UR-100
The model 68 transmitter
has 12 columns of posts,
each column has 3 posts.
(see diagram C)
2a. To program the model
68, open the case with
a coin. (see diagram B)
2b. There are 2 ways to pro-
gram the model 68 so
that it will communicate
with your garage door
opener. Open your exist-
ing transmitter, (the unit
you currently use to open
your garage), or look at
the back of your garage
door opener. If you see a
column of small switches
go to point 2c in this
manual. If there are no
switches, go to point 2e.
Diagram B
Each column contains one
connector (see digram D)
for a total of 12 connectors.
Diagram D
Diagram E
If the connector is placed
on the top and middle posts,
that column is set on “ + ”
or “ON” or “CLOSE”. If the
connector is placed on the
middle and bottom posts,
that column is set on “ - ”
or “OFF” or “OPEN”. If the
connector is removed
completely, (not placed
on any posts), it is set
to “ 0 ” or the neutral
position.(see diagram E
for examples of how to
set a column to the three
different positions). When
removing a connector to
set a column to the neu-
tral position, save the con-
nector in case you change
the code at a later date.
2c. To move the connectors,
slide an opened paper clip
into the side of a connector
and lift. (see diagram F)
When repositioning con-
nectors, place a connector
on the two chosen posts,
then push down on the
connector with your finger.
Paper
Clip
Diagram F
Diagram C
USA
CANADA
A
390
390
B
318
318
C
310
315
D
300
310
STEP 2 - SET CODE CONNECTORS
Linear *Position 1 to 8 + OR -
M-O-M *Position 1 to 8 + OR -
Stanley (310) Canada Position 1 to 10 + OR - 11,12 set to ‘+’ or ‘-’
Stanley (300) Position 1 to 10 + OR - 11,12 set to ‘+’ or ‘-’
Multi-Code Position 1 to 10 + OR - 11,12 set to ‘+’ or ‘-’
Chamberlain Position 1 to 9 +, 0 (blank), OR -
Lift-Master Position 1 to 9 +, 0 (blank), OR -
Sears Position 1 to 9 +, 0 (blank), OR -
Wayne Dalton Position 1 to 9 +, 0 (blank), OR -
Master Mechanic Position 1 to 9 +, 0 (blank), OR -
Genie (9 positions) Position 1 to 9 + OR -
Genie (12 positions) Position 1 to 12 + OR -
Master Craft Position 1 to 12 + OR -
Pulsar/Allister/Allstar Position 1 to 9 +, 0 (blank), OR -
Overhead Door Position 1 to 9 +, 0 (blank), OR -
Code connector setting to match your opener/motor
1a. Locate frequency
switch on the bottom
of the transmitter:
(see diagram A)
Diagram A
1b. Determine the brand of your garage door
opener and set the frequency switch to the
corresponding position. (see chart 1)
STEP 1 - SET FREQUENCY SWITCH
Thank you for your purchase of the Skylink garage door
remote control, Model 68. There are 2 different steps
you need to setup in order to use this universal garage
door remote control to operate your existing garage door
opener. These 2 steps are:
1) Frequency switch – select the correct frequency
according to the brand of your existing garage door
opener.
2) Code setting – Set the jumper connectors on the
Model 68 so that they match the code setting of your
existing garage door opener.
Please follow the detailed instructions below in order to set-
up the Skylink Model 68 to work with your existing opener.
NOTE: Transmission range may be reduced with use
on a metal garage door.
PROGRAMMING THE TRANSMITTER
Diagram G
Set the connectors numbered 1 through 12 to match the
switches of your existing transmitter or receiver. If your
garage door opener is manufactured by (Stanley®, Genie® ,
Multi-Code® , Linear® , Moore-O-Matic® ) these switches
may only have two positions, (“ +, ON, CLOSED” and “ - ,
OFF, OPEN”). (see diagram G) Set the connectors on the
model 68 to “ + ” if your existing switches are either “+ ,
ON, CLOSE ” and set to “ - ” if your existing switches are
either “ -, OFF, OPEN”. Do not use the center position “ 0 ”.
Examples of how to set Model 68
*Please check the FAQ section from www.skylinkhome.com for very old Linear / M-O-M systems.
Chart 1
390
390
390
300/390
390
390
390
390
318
-
310
310
300/310
300/310
390
A
A
A
D/A
A
A
A
A
B
-
C
C
D/C
D/C
A
315/390
315/390
315/390
315/390
315/390
315/390
315/390
315/390
318
315/390
310
310
310
310
390
C/A
C/A
C/A
C/A
C/A
C/A
C/A
C/A
B
C/A
D
D
D
D
A
Brand of your opener Set switch
to position Set switch
to position
Frequency Frequency
USA CANADA
Model 68
Existing
Transmitter
‘+’ or ‘ON’ or CLOSE ‘0’ = BLANK
‘-’ or ‘OFF’ or ‘OPEN’
STEP 2 - SET CODE CONNECTORS


Produkt Specifikationer

Mærke: Skylink
Kategori: Garagepoortopener
Model: 68 - remote

Har du brug for hjælp?

Hvis du har brug for hjælp til Skylink 68 - remote stil et spørgsmål nedenfor, og andre brugere vil svare dig