SolarEdge MTR-240-3PC1-D-A-MW Manual

SolarEdge Ikke kategoriseret MTR-240-3PC1-D-A-MW

Læs nedenfor 📖 manual på dansk for SolarEdge MTR-240-3PC1-D-A-MW (18 sider) i kategorien Ikke kategoriseret. Denne guide var nyttig for 26 personer og blev bedømt med 4.5 stjerner i gennemsnit af 2 brugere

Side 1/18
A
Inline Energy Meter
Quick Installation Guide
For Europe, APAC and South Africa
B
solaredge.com
Werner- - 6/Eckert Strasse 81829
Munich/GermanySolarEdge
Technologies Gmbh
Subject notice.to change without
© SolarEdge Technologies, Ltd.
All rights reserved. August 2021.
Usage Options
Mounting and Wiring
Box Contents
One (1) Energy meter
One ( ) Quick Installation Guide 1
One (1) RS485 Terminal block
1
34
Default Communication Metal Enclosure or Extended Range
Datasheet
See section C on back page for optional Modbus communication
Scan for SolarEdge
Energy Net plug-in kits
to use with the inverter
SolarEdge Energy Net
Complete Installation guide
Scan for SolarEdge Energy
Net plug-in installation guide
WARNING! HAZARD OF
ELECTRIC SHOCK DISCONNECT
POWER BEFORE SERVICE OR
INSTALLATION
NL3L2L1
Cross-section: 1.5 25 mm2/ 15 3 - AWG
L1
L2
L3
N
3 - 2%)Ø Meter Wiring Accuracy class A (
NL3L2L1
N
L3
L2
L1
Cross-section: 1.5 25 mm2/ 15 3 - AWG
OFF
3 - 1%)Ø Meter Wiring Accuracy class B (
CAUTION! DO NOT use circuit
breaker with a rated current of
more than 65A
N
L
Cross-section: 1.5 25
mm2/ 15 3 - AWG
230 400 / VAC Wye
Grid (max. 65A)
1 -Ø Meter Wiring Accuracy class B (1%)
CAUTION! DO
NOT use circuit
breaker with a
rated current of
more than 65A
NL
1.2Nm
1.2Nm
Connect to L3 when using this meter in 1Ø grid
Connect to L3 when using this meter in 1Ø grid
1.2Nm
RS485 Defaults:
Termination = ON
ID = 2
1
2
3
4
3 /X 230 400 VAC Wye Grid
(max. 65A per each phase)
3 /X 230 400 VAC Wye Grid
(max. 65A per each phase)
1.1Nm
2
Scan for External Energy Net
antenna installation guide
1 - 2%)Ø Meter Wiring Accuracy class A (
NL
NL
Cross-section: 1.5 –
25 mm2/ 15 3 - AWG
CAUTION! DO
NOT use circuit
breaker with a
rated current of
more than 65A 230 400 / VAC Wye
Grid (max. 65A)
1.2Nm
DE FR HU IT
NL PL SP SWE


Produkt Specifikationer

Mærke: SolarEdge
Kategori: Ikke kategoriseret
Model: MTR-240-3PC1-D-A-MW

Har du brug for hjælp?

Hvis du har brug for hjælp til SolarEdge MTR-240-3PC1-D-A-MW stil et spørgsmål nedenfor, og andre brugere vil svare dig




Ikke kategoriseret SolarEdge Manualer

Ikke kategoriseret Manualer

Nyeste Ikke kategoriseret Manualer

Snom

Snom HD300A Manual

4 November 2024
Atlona

Atlona NETGEAR-AXM Manual

4 November 2024
Sanus

Sanus VMF822 Manual

4 November 2024
Sanus

Sanus VLF828 Manual

4 November 2024
Sanus

Sanus VSF817 Manual

4 November 2024
BEKO

BEKO BHCP65422BCH Manual

4 November 2024
Blaupunkt

Blaupunkt GG3010 Manual

4 November 2024
Blaupunkt

Blaupunkt BP-YF07D Manual

4 November 2024
Blaupunkt

Blaupunkt GG6010 Manual

4 November 2024