StarTech.com PDU08C13AU Manual


Læs nedenfor 📖 manual på dansk for StarTech.com PDU08C13AU (2 sider) i kategorien Strømskinne. Denne guide var nyttig for 5 personer og blev bedømt med 4.5 stjerner i gennemsnit af 2 brugere

Side 1/2
Instruction manual
FR: Guide de l’utilisateur - fr.startech.com
DE: Bedienungsanleitung - de.startech.com
ES: Guía del usuario - es.startech.com
NL: Gebruiksaanwijzing - nl.startech.com
PT: Guia do usuário - pt.startech.com
IT: Guida per l’uso - it.startech.com
Manual Revision: 09/27/2016
For the latest information, technical specications, and support for
this product, please visit www.StarTech.com/PDU08C13AU.
PDU08C13AU
8-Port Rack-Mount PDU with C13 Outlets - 1U - 16 A
*actual product may vary from photos
Introduction
The PDU08C13AU is a cost-eective power distribution solution
that you can mount in your rack to deliver power to your rack-
mounted equipment. The PDU is constructed from durable steel and
mounts horizontally in your rack, taking up only 1U of space. The
PDU features a dual circuit breaker that is designed to protect your
equipment from power surges, and two reset buttons that you can
use to reset the PDU after a power surge.
Product diagram
C13 outlets Reset buttons
C20 power port
Mounting
holes Mounting
holes
Package contents
1 x rack-mount PDU
1 x 10 ft. (3 m) C19 to AS3112 power cord
4 x screws
4 x cage nuts
1 x instruction manual
Requirements
Power source
1U of space in a server rack
Requirements are subject to change. For the latest requirements,
please visit www.StarTech.com/PDU08C13AU.
Install the rack-mount PDU
The rack-mount PDU takes up 1U of space.
1. Line up the on the rack-mount PDU with the Mounting holes
mounting holes on your server rack.
2. Use the provided screws and cage nuts or the mounting hardware
that came with your rack to attach the rack-mount PDU to your
server rack.
3. Connect the power cord to the C20 power port on the rack-
mount PDU and a power source. Make sure that you connect the
power cord directly to the power source and not another PDU.
4. Connect the devices in your server rack to the on the C13 outlets
rack-mount PDU.
Caution! The combined power draw of all of the devices attached to
the rack-mount PDU shouldn’t exceed 16 A, otherwise you will trip
the built-in circuit breaker.
Troubleshooting
What do I do if I trip the circuit breaker?
If you trip the circuit breaker, complete the following:
1. Make sure that the combined power draw of all of the devices
attached to the rack-mount PDU doesn’t exceed 16 A.
2. Press one of the on the rack-mount PDU.Reset buttons
Specications
Input C20
Output C13 (x8)
Voltage 100 to 240 V ac
Maximum current 16 A
Number of fuses 2