Hand held Anemometer
Operating Manual
Introduction:
Congratulations on purchasing this pocket-sized anemometer, this innovative product provides
wind speed, wind chill and temperature information for any outdoor activities. The operation of
this product is simple and straightforward and by reading this operating manual, users will
receive the optimum benefits of all its features.
The Anemometer
Features:
• Wind speed measure in mph, Km/h, m/s or Knots
• Wind speed in Beauford wind scale bar graph
• Wind chill display
• Temperature display in degrees Celsius or Fahrenheit
• LCD back-light
• Auto power OFF
• Neck band included
• Water resistance
Setting up:
1. Firstly, use a large coin to open the battery
cover at the back of the anemometer as
indicated above.
2. Checking the correct polarization, insert
1 x 3V (CR2032) lithium cell, positive (+) pole up
into the battery compartment and replace the
cover.
3. When the battery is inserted, all the segments of
the LCD and back-light will light up briefly.
Your anemometer is now operational.
Note:
After inserting the battery, test the anemometer by blowing directly at the Impeller for about 30
seconds. The reading on the LCD should change. If it is not the case, remove the battery. Wait
for 30 seconds, and re-insert the battery again.
Function keys:
The anemometer uses the following keys:
MODE/~
~
~
~~ key : To toggle between wind speed and temperature/wind chill display
: Power ON/OFF
: To enter the setting node
: Back-light-On
+ Key : To change operation mode
(PLUS) : To change parameter in setting mode
: Back-light-On
Selection of operation mode
There are two modes, one is wind speed, and another is temperature. By pressing the
“MODE/~
~
~
~~” key the display will toggle between wind speed and temperature/wind chill
Wind speed Mode
The wind speed mode can be selected into 3 different displays at any time.
To toggle between current wind speed, maximum wind speed and average wind speed, simply
press the “+” key:
Beaufort wind
scale (bft)
The Beaufort scale is
displayed in bar graph
(0-12). This is a system
for estimating wind
force without the use of
instruments based on
the visible effects of the
wind on the physical
environment.
Temperature and Wind chill Mode
The Temperature and wind chill modes can be selected into 2 different displays at any time.
Temperature Wind chill
By pressing the “+” key the display will toggle between temperature and wind chill.
When the temperature is outside the range from –29.9°C to +59°C, there will be no wind chill
measurement.
Wind chill
The anemometer calculates automatically wind chill, which can provide useful information for
preparing outdoor activities in cold weather. “Wind chill” provides an indication of how cold it feels
given the combined effects of the actual air temperature and the wind speed.
Power ON/OFF:
Press and hold down the “MODE/~
~
~
~~” key for 2 seconds to switch ON/OFF.
Note:
The anemometer is automatically switched OFF when no key is pressed in 34 minutes.
Manual setting
Before entering the manual setting mode, switch off the anemometer.
Press and hold down the “MODE/~
~
~
~~” key for about 4 seconds, the speed unit will start flashing
on the LCD when the manual setting mode is entered.
Measurement scale setting
1. After entering the manual setting mode, press “+” key to set the measurement scale in
Km/h (Kilometers per hour), mph (miles per hour), m/s (meters per seconds) or Kts
(Knots).
2. Now press the “MODE/~
~
~
~~” key to confirm and enter the “°C and °F setting”.
°C and °F setting:
1. Following from the measurement scale Setting °C will be flashing, use the “+” key to toggle
°C and °F.
2. Once the desired temperature unit has been chosen, press the “MODE/~
~
~
~~” key to confirm
and enter the “Average time for current speed measurement setting”.
Average time for current speed measurement setting
The current wind speed can be measured in average wind speed in a time interval 2-10 seconds
1. Following from the °C and °F Setting, press “+” key to set the desired average time. The
range runs from 2 to 10 seconds.
2. Once the desired average time has been chosen, press the “MODE/~
~
~
~~” key to confirm
and back to the normal mode.
LCD back-light:
The LCD back-light is automatically switched ON when any one of the 2 function keys are
pressed and held down about 2 seconds. The back-light will be switched on for approximately 8
seconds before automatically switching OFF.
Fastening the necklace
The carry necklace is supplied with the anemometer.
To fasten, simply insert the clip of the necklace into the buckle end
of the anemometer until it clicks into place.
To unfasten, simply press both sides of the clip until it can be
removed from the buckle.
Battery change:
It is recommended to replace the battery in the unit on an annual basis to ensure optimum
accuracy of this unit.
Please help in the preservation of the environment. Return used batteries to an
authorised depot.
Maintenance:
• Avoid placing anemometer in areas prone to vibration and shock as these may damage and
inaccurate readings.
• Avoid exposure to sudden changes in temperature such as direct sunlight, extreme cold and
wet or moist conditions.
• When cleaning the display and casing, use a soft damp cloth only.
Do not use solvents or souring agents as they may mark the LCD and casing.
• Do not make or attempts to make any repairs to the anemometer. Return it to its original point
of purchase for repair by a qualified engineer. Opening and tampering with the unit may
invalidate its guarantee.
Specifications:
Recommended operating temperatures : -29.9°C to +59°C with 0.1°C resolution
(“---“ displayed if outside this range)
Temperature checking interval : every 10 seconds
Wind speed measuring range : Minimum 0.2 m/s
Maximum 30 m/s
Wind speed accuracy : ±5% or ± least significant digit
Power source : 1 x 3V lithium cell (CR2032)
Battery life : Approximately 12 months
(The battery life might be shorter than 12
months depending on the use of the
backlight.)
Dimensions (L x W x H) : 39 x 17 x 98 mm
Liability Disclaimer:
• The manufacturer and supplier cannot accept any responsibility for any incorrect readings
and any consequences that occur should an inaccurate reading take place.
• This product is not to be used for medical purposes or for public information.
• The specifications of this product may change without prior notice.
• This product is not a toy. Keep out of the reach of children.
• No part of this manual may be reproduced without written consent of the
manufacturer.
Batter
y
cove
r
Battery
compartment
Current wind speed Maximum wind speed
Since power on Average wind s eedp
Since power on
Battery
cover
+ key
MODE/~
~
~
~~ key
Im
p
elle
r
+
Lithium cell
(CR2032)
Force Description Kts m/s Km/h mph
0 Calm 0 0 0 0
1 Light Air 1 0.5 1.8 1.1
2 Light Breeze 4 2.1 7.4 4.6
3 Gentle Breeze 7 3.6 13.0 8.1
4 Moderate Breeze 11 5.7 20.4 12.7
5 Fresh Breeze 17 8.8 31.5 19.6
6 Strong Breeze 22 11.3 40.8 25.4
7 Near Gale 28 14.4 51.8 32.3
8 Gale 34 17.5 63.0 39.2
9 Strong Gale 41 21.1 75.9 47.2
10 Storm 48 24.7 88.9 55.3
11 Violent Storm 56 28.8 103.7 64.5
12 Hurricane 64 32.9 118.5 73.7
Produkt Specifikationer
Mærke: | Techno Line |
Kategori: | Vejrstation |
Model: | EA 3010 |
Har du brug for hjælp?
Hvis du har brug for hjælp til Techno Line EA 3010 stil et spørgsmål nedenfor, og andre brugere vil svare dig
Vejrstation Techno Line Manualer
16 November 2024
4 September 2024
3 September 2024
2 September 2024
2 September 2024
26 August 2024
21 August 2024
21 August 2024
21 August 2024
21 August 2024
Vejrstation Manualer
- Vejrstation OBH Nordica
- Vejrstation Denver
- Vejrstation Sencor
- Vejrstation Day
- Vejrstation Beurer
- Vejrstation Daikin
- Vejrstation Extech
- Vejrstation Vitek
- Vejrstation Medisana
- Vejrstation Braun
- Vejrstation Tanita
- Vejrstation Emos
- Vejrstation Daewoo
- Vejrstation Lowrance
- Vejrstation TFA
- Vejrstation Livoo
- Vejrstation Pyle
- Vejrstation Biltema
- Vejrstation Hama
- Vejrstation Muse
- Vejrstation Thomson
- Vejrstation Hyundai
- Vejrstation Theben
- Vejrstation Clas Ohlson
- Vejrstation Optex
- Vejrstation Trevi
- Vejrstation Rocktrail
- Vejrstation Blaupunkt
- Vejrstation Honeywell
- Vejrstation Clatronic
- Vejrstation Soehnle
- Vejrstation König
- Vejrstation Elro
- Vejrstation Auriol
- Vejrstation Ventus
- Vejrstation Balance
- Vejrstation Sjöbo
- Vejrstation Bresser
- Vejrstation Davis
- Vejrstation Jacob Jensen
- Vejrstation National Geographic
- Vejrstation Alecto
- Vejrstation Krontaler
- Vejrstation GlobalTronics
- Vejrstation Rain Bird
- Vejrstation Velleman
- Vejrstation Perel
- Vejrstation JUNG
- Vejrstation Netatmo
- Vejrstation Eurochron
- Vejrstation Technoline
- Vejrstation Fluke
- Vejrstation EQ3
- Vejrstation La Crosse Technology
- Vejrstation ADE
- Vejrstation Cotech
- Vejrstation ECG
- Vejrstation Elgato
- Vejrstation EVE
- Vejrstation Renkforce
- Vejrstation Waldbeck
- Vejrstation Brandson
- Vejrstation Orion
- Vejrstation Irox
- Vejrstation Majestic
- Vejrstation Mebus
- Vejrstation Vimar
- Vejrstation Oregon Scientific
- Vejrstation PeakTech
- Vejrstation Chacon
- Vejrstation Lexibook
- Vejrstation Ascot
- Vejrstation AcuRite
- Vejrstation Avidsen
- Vejrstation Chauvin Arnoux
- Vejrstation Taylor
- Vejrstation GoGen
- Vejrstation Levenhuk
- Vejrstation Minox
- Vejrstation Homematic IP
- Vejrstation ClimeMET
- Vejrstation Steren
- Vejrstation Bearware
- Vejrstation Setti+
- Vejrstation Profile
- Vejrstation Cresta
- Vejrstation Brigmton
- Vejrstation Marquant
- Vejrstation UPM
- Vejrstation Gira
- Vejrstation ELV
- Vejrstation Dexford
- Vejrstation Kemot
- Vejrstation Buienradar
- Vejrstation Saxon
- Vejrstation HomeMatic
- Vejrstation La Crosse
- Vejrstation Durabase
- Vejrstation Meade
- Vejrstation Guardo
- Vejrstation Sempre
- Vejrstation Digi-tech
- Vejrstation Unitec
- Vejrstation TFA Dostmann
- Vejrstation Greisinger
- Vejrstation Nor-tec
- Vejrstation DMV Electronics
- Vejrstation Inovalley
- Vejrstation Balance Meteo
- Vejrstation Ease Electronicz
- Vejrstation Rebel
- Vejrstation Saphir
- Vejrstation Paget Trading
- Vejrstation YONO
- Vejrstation Ytora
- Vejrstation JDC
- Vejrstation Greenure
- Vejrstation PCE Instruments
- Vejrstation Nasa
- Vejrstation Global Water
- Vejrstation ChiliTec
- Vejrstation Uzoli
- Vejrstation Xeecom ApS
- Vejrstation Marathon
- Vejrstation Ea2 LABS
- Vejrstation Hesdo
- Vejrstation Weinberger
- Vejrstation EMOS SELECT
- Vejrstation Prologue
- Vejrstation Gewiss
- Vejrstation Browin
- Vejrstation Otio
- Vejrstation Baldr
- Vejrstation Thierry Mugler
Nyeste Vejrstation Manualer
17 November 2024
17 November 2024
12 November 2024
8 Oktober 2024
5 Oktober 2024
5 Oktober 2024
4 Oktober 2024
3 Oktober 2024
2 Oktober 2024
1 Oktober 2024