Techno Line WS 9624 IT Manual


Læs nedenfor 📖 manual på dansk for Techno Line WS 9624 IT (46 sider) i kategorien Vejrstation. Denne guide var nyttig for 18 personer og blev bedømt med 4.5 stjerner i gennemsnit af 2 brugere

Side 1/46
Prod.-Nr. 095.689 6 L-Nr. L778/263
WIRELESS 868 MHz WEATHER STATION
Instruction Manual
INTRODUCTION:
Congratulations on purchasing this Weather station with wireless 868MHz transmission. It not
only displays the indoor temperature and humdity, but also the outdoor temperature and
humidity. It is further acting as a DCF-77 radio controlled clock. With the totally 15 different
weather forecast icons featured by "weather girl", users can easily observe the forecast weather
condition and will no longer worry the sudden weather change. This innovative product is ideal
for use in the home or office.
50
FEATURES:
51
LCD
Displa
y
The Weather station
DCF Radio controlled time function or manual time setting option
Function
Keys
Foldout
Stand
Battery
compartment
cover
Hanging hole
DCF time reception ON/OFF setting
12/24 hour display
52
Hour and minute and second display
Time zone option ±12 hours
Wireless transmission at 868 MHz
Signal reception intervals at 4-second
Display indoor and outdoor temperature and humidity (% RH)
Temperature display in degrees Celsius (°C) or Fahrenheit (°F) selectable
Weather forecasting with 15 easy-to-read weather forecast signs featured by weather
girl
Weather forecasting icon sensitivity setting
Indoor and Outdoor temperature and humidity display with MIN/MAX recording
MIN/MAX records show date and time received of the temperature, and all MIN/MAX
recordings can be reset
Can take up to three outdoor transmitters
Display Daily Outdoor Min and Max temperature
LCD contrast setting
Low battery indicator
Table standing/ Wall mounting
53
The Outdoor Thermo-hygro Transmitter
Remote transmission of outdoor temperature and humidity to
Weather Station by 868 MHz
Display alternately the outdoor temperature and humidity readings on
LCD
Shower proof casing
Wall mounting case (Mounting at a sheltered place. Avoid direct rain
and sunshine)
SETTING UP:
When one transmitter is used
1. First, insert the batteries into the Thermo-hygro transmitter. (seeInstall and replace
batteries in the Thermo-hygro transmitter transmitter“).
2. Immediately after and within 25 seconds, insert the batteries into Weather station (see
Install and replace batteries in the Weather station”). Once the batteries are in place,
all segments of the LCD will light up briefly. Following the time as 0:00 and the "weather
54
girl" icon will be displayed. If these are not displayed after 60 seconds, remove the
batteries and wait for at least 10 seconds before reinserting them.
3. After inserting the batteries, the Weather station will start receiving data from the
transmitter. The outdoor temperature & humidity and the signal reception icon should
then be displayed on the Weather station. If this does not happen after 3 minutes, the
batteries will need to be removed from both units and reset from step 1.
4. In order to ensure sufficient 868 MHz transmission however, this should under good
conditions be a distance no more than 100 meters between the final position of the
Weather Station and the transmitter (see notes on “Mounting” and “868 MHz
Reception”).
5. Once the remote temperature has been received and displayed on the Weather station,
the DCF time (radio controlled time) code reception is automatically started. This takes
typically between 3-5 minutes in good conditions. If after 10 minutes, the DCF time has
not been received, press the SET key to manually enter a time initially.
When more than one transmitter is used
1. User shall remove all the batteries from the weather station and transmitters and wait for
60 seconds if setting has been done with one transmitter before.
2. Insert the batteries to the first transmitter.
3. Within 25 seconds of powering up the first transmitter, insert the batteries to the Weather
Station. Once the batteries are in place, all segments of the LCD will light up briefly.
Following time as 0:00 and the weather girl icon will be displayed. If they are not shown in
55
LCD after 60 seconds, remove the batteries and wait for at least 60 seconds before
reinserting them.
4. The outdoor temperature and humidity from the first transmitter (channel 1) should then be
displayed on the Weather station. Also, the signal reception icon will be displayed. If this
does not happen after 2 minutes, the batteries will need to be removed from both units
and reset from step 1.
5. Insert the batteries to the second transmitter as soon as the outdoor temperature &
humidity readings from the first transmitter are displayed on the Weather station.
Note: User shall insert the batteries into the second transmitter within 10 seconds of reception
of the first transmitter.
6. The outdoor data from the second transmitter and the "channel 2" icon should then be
displayed on the Weather station. If this does not happen after 2 minute, the batteries will
need to be removed from all the units and reset from step 1.
7. Insert the batteries to the third transmitter as soon as the "channel 2" icon and outdoor
data are displayed on the Weather station. Then within 2 minutes, the channel 3 outdoor
data from the third transmitter will be displayed and the channel icon will shift back to "1"
once the third transmitter is successfully received. If this is not happen, user shall restart
the setting up from step 1.
Note:
User shall insert the batteries into the third transmitter within 10 seconds of reception of
56
the second transmitter.
And user may require to check the displayed readings on the weather station
against those shown on the transmitters in order to recognise the Channel No. of
each transmitter.
8. In order to ensure sufficient 868 MHz transmission however, this should under good
conditions be a distance no more than 100 meters between the final position of the
Weather Station and the transmitter (see notes onMounting” and “868 MHz
Reception”).
IMPORTANT:
Transmission problems will arise if the setting for additional sensors is not followed as described
above. Should transmission problems occur, it is necessary to remove the batteries from all units
and start again the set-up from step 1.
9. Once the remote temperature has been received and displayed on the Weather station,
the DCF time (radio controlled time) code reception is automatically started. This takes
typically between 3-5 minutes in good conditions.
If after 10 minutes, the DCF time has not been received, press the SET key to manually enter a
time initially.
57
Note:
Daily DCF reception is done at 02:00 and 03:00 every day. If the reception at 03:00 is not
successful, then at 04:00 and 05:00 and 06:00 there are other tries, until one is successful. If the
reception at 06:00 is still not successful, then the next try takes place at 02:00 next day.
If reception is successful, the received time will override the manually set time. The date is also
updated with the received time. (Please refer also to notes on “DCF Reception” and “Manual
Time Setting”)
Please participate in the preservation of the environment. Return used
batteries to an authorised depot.
60
FUNCTION KEYS:
Weather station:
The weather station has four easy to use function keys.
SET key
MIN
/
MAX ke
y
+ key
CH ke
y
LCD SCREEN AND SETTINGS:
62
Indoor Relative
Humidity %
Weather
Tendency indicator
Weathe
r
Forecast icon
(Weather girl)
Time
Outdoor Temperature
Outdoor
Reception
Signal*
Transmitter identification
(channel No.)
Indoor Temperature
Radio controlled time
reception icon
Transmitter low
battery indicator
Outdoor Relative
Humidity %
Daily max outdoor
temp
Date
Daily min
outdoor temp
Receiver lo
w
battery indicato
r
64
TENDENCY")
Section 4 - OUTDOOR TEMPERATURE AND HUMIDITY
Display the outdoor temperature and humidity of the currently selected channel.
Section 5 - DAILY OUTDOOR MINIMUM AND MAXIMUM TEMPERATURE
Display the daily outdoor minimum and maximum temperature of the currently selected
channel.
DCF-77 RADIO CONTROLLED TIME:
The time base for the radio controlled time is a Cesium Atomic Clock operated by the
Physikalisch Technische Bundesanstalt Braunschweig which has a time deviation of less than
one second in one million years. The time is coded and transmitted from Mainflingen near
Frankfurt via frequency signal DCF-77 (77.5 kHz) and has a transmitting range of approximately
1,500 km. Your radio-controlled Weather station receives this signal and converts it to show the
precise time in summer or wintertime. The quality of the reception depends greatly on the
geographic location. In normal cases, there should be no reception problems within a 1,500 km
radius around Frankfurt.
Once the outdoor temperature is displayed on the Weather station after initial set-up, the DCF
tower icon in the clock display will start flashing in the upper left corner. This indicates that the
65
clock has detected that there is a radio signal present and is trying to receive it. When the time
code is received, the DCF tower becomes permanently lit and the time will be displayed.
If the tower icon flashes, but does not set the time or the DCF tower does not appear at all, then
please take note of the following:
Recommended distance to any interfering sources like computer monitors or TV sets is a
minimum of 1.5 - 2 metres.
Within ferro-concrete rooms (basements, superstructures), the received signal is naturally
weakened. In extreme cases, please place the unit close to a window and/or point its front
or back towards the Frankfurt transmitter.
MANUAL SETTINGS:
The following manual settings can be done in the setting mode:
LCD contrast setting
Time zone setting
Time reception ON/OFF setting
12/24-Hour setting
Manual time setting
Calendar setting
°C/ °F setting
Weather forecasting icon sensitivity setting
Press the SET key to advance to the setting mode:
LCD CONTRAST SETTING
66
The LCD contrast can be set to 8 different levels to suit the users needs (default LCD contrast
setting is LCD 4). To set the desired contrast level:
1. The above display will be seen. Press the + key to select the level of contrast desired.
2. Press the SET key to confirm and enter the “Time Zone setting” or exit the setting mode
by pressing the CH key
TIME ZONE SETTING:
flashing
flashing
The time zone default is "0 hour". To set a different time zone:
1. The current time zone value starts flashing.
2. Use the + key to set the time zone. The range runs from 0, -1, -2…-12, 12, 11, 10… 2, 1,
0, in consecutive 1-hour intervals.
3. Confirm with the SET key and enter the Time reception On/ Off setting.
TIME RECEPTION ON/OFF SETTING
flashing
Flashing
(time reception icon)
In area where reception of the radio-controlled time (DCF time) is not possible, the time
reception function can be turned OFF. The clock will then work as a normal Quartz clock.
(Default setting is ON).
1. The digit “ON” and the time reception icon will start flashing on the LCD.
2. Use the + key to turn OFF the time reception function.
3. Confirm with the SET key and enter the or exit the setting “12/24-Hour Display setting”
mode by pressing the CH key.
67
Note:
If the Time Reception function is turned OFF manually, the clock will not attempt any
reception of the radio-controlled time (DCF time) as long as the Time Reception OFF
function is activated. The Time Reception icon will not be displayed on the LCD.
12/24 HOUR TIME DISPLAY SETTING
flashing
1. After setting time reception ON/OFF, press the SET key, “12h” or “24h” flashes in the LCD.
(default 24 h)
2. Press the + key to select the “12h” or “24h” display mode.
3. Press the SET again to confirm and to enter the “Manual Time setting” or exit the setting
mode by pressing the CH key.
Note: When 24h mode display is selected, the calendar format will be "Day. Month." display.
When 12h mode display is selected, the calendar format will be "Month. Day." display.
68
MANUAL TIME SETTING
In case the Weather station is not able to detect the radio-controlled time (DCF time) signal
(disturbances, transmitting distance, etc.), the time can be manually set. The clock will then work
as a normal Quartz clock.
Hours (flashing)
Minutes (flashing)
To set the clock:
1. The hour digits start flashing in the time display section.
2. Use the + key to adjust the hours and then press SET key to go to the minute setting.
3. The minute will be flashing. Press the + key to just the minutes.
4. Confirm with the SET key and enter the “Calendar Setting” or exit the setting mode by
pressing the CH key
CALENDAR SETTING
Year
69
°C/°F TEMPERATURE UNIT SETTING
flashing
The default temperature reading is set to °C (degree Celsius).
To select °F (degree Fahrenheit):
1. The “°C or F” will be flashing, use the + key to toggle between “°C” and “°F”. °
2. Once the desired temperature unit has been chosen, confirm with the SET key and enter
the “Weather Forecast Icon Sensitivity setting” or exit the setting mode by pressing the
CH key.
WEATHER FORECASTING ICON SENSITIVITY SETTING
For locations with rapid changes of weather conditions, the threshold can be set to a different
level for faster display of changing weather conditions.
71
Sensitivity level
(flashing)
1. Using the + key to set the weather sensitivity level. There are 3 levels of setting: 2, 3 and
4 (hPa). It is the threshold value of pressure change that will activate a change in weather
icon. For example, when "2" is selected, it means that a change in 2 hPa will make the
weather icon change. So '2" is the most sensitive setting, "4" is the least sensitive setting
(default setting is "3").
2. Confirm with the SET key and exit the Manual settings.
WEATHER FORECAST AND TENDENCY:
The weather forecast icons (Weather girl):
One of the 15 different weather icons (featured by Weather girl with different clothing) is
displayed in the centre of LCD, which indicate the different forecast weather condition due to air
pressure level (Sunny, Sunny + Cloudy or Cloudy + Rainy) and the current outdoor temperature
72
(Temperature value detected by Transmitter channel 1) :
°
°
°
°° 78.8 F
(
26°
°
°
°°C)
66.2 to 78.6°
°
°
°°F
(19 to 25.9°
°
°
°°C)
50 to 66°
°
°
°°F
(10 to 18.9°
°
°
°°C)
32 to 49.8°
°
°
°°F
(0 to 9.9°
°
°
°°C)
< 32°
°
°
°°F
(< 0°
°
°
°°C)
Sunny
73
75
For every sudden or significant change in the air pressure, the weather icons will update
accordingly to represent the change in weather. If the icons do not change, then it means either
the air pressure has not changed or the change has been too slow for the Weather Projection
Station to register. However, if the icon displayed is a sun or raining cloud, there will be no
change of icon if the weather gets any better (with sunny icon) or worse (with rainy icon) since
the icons are already at their extremes.
The icons displayed forecasts the weather in terms of getting better or worse and not necessarily
sunny or rainy as each icon indicates. For example, if the current weather is cloudy and the rainy
icon is displayed, it does not mean that the product is faulty because it is not raining. It simply
means that the air pressure has dropped and the weather is expected to get worse but not
necessarily rainy.
Note :
After setting up, readings for weather forecasts should be disregarded for the next 12-24 hours.
This will allow sufficient time for the Weather Station to collect air pressure data at a constant
altitude and therefore result in a more accurate forecast.
Common to weather forecasting, absolute accuracy cannot be guaranteed. The weather
forecasting feature is estimated to have an accuracy level of about 75% due to the varying areas
the Weather Station has been designed for use in. In areas that experience sudden changes in
weather (for example from sunny to rain), the Weather Station will be more accurate compared
to use in areas where the weather is stagnant most of the time (for example mostly sunny).
76
If the Weather Station is moved to another location significantly higher or lower than its initial
standing point (for example from the ground floor to the upper floors of a house), remove the
batteries and re-insert them after about 30 seconds. By doing this, the Weather Station will not
mistake the new location as being a possible change in air-pressure when really it is due to the
slight change of altitude. Again, disregard weather forecasts for the next 12 to 24 hours as this
will allow time for operation at a constant altitude.
THE WEATHER TENDENCY INDICATOR
Working together with the weather icons are the weather tendency indicators (the upward and
downward arrows located on the right hand side of the weather girl icon). When the indicator
points upwards, it means that the air-pressure is increasing and the weather is expected to
improve, but when indicator points downwards, the air-pressure is dropping and the weather is
expected to become worse.
Therefore, user may see how the weather has changed and is expected to change. For example,
if the indicator is pointing downwards together with cloudy icons, it means that the last noticeable
change in the weather was when it was sunny (the sunny icon only). Therefore, the next change
in the weather will be the cloudy icons since the indicator is pointing downwards.
Note:
Once the weather tendency indicator has registered a change in air pressure, it will remain
permanently visualized on the LCD.
DISPLAY OF INDOOR TEMPERATURE AND HUMIDITY READING:
The indoor temperature and humidity are measured and displayed on the second section of the
LCD.
77
DISPLAY OF OUTDOOR TEMPERATURE AND HUMIDITY READING:
The outdoor temperature and humidity are measured and displayed on the fourth section of the
LCD.
Indoo
r
Temperature
Indoor Relative
Humidity %
Indoor icon
Outdoor
Humidity
Transmitter identification No.
(shown when more than one
transmitter is used)
Outdoor icon
Outdoor
Temperature
78
Note:
The channel number will shown if more than one transmitter has been used.
DISPLAY OF OUTDOOR MAXIMUM AND MINIMUM RECORDS:
1. In normal display mode, press the CH button to select the desired channel. The channel
ID will be displayed next to the outdoor temperature reading.
2. Press the MIN/MAX button once, the max outdoor temperature and humidity of the
selected channel will be displayed. Also the time and date of recording this temperature
will be displayed:
Note: The time and date of recording the min/max humidity reading will not be shown.
79
3. By pressing MIN/MAX button once more, the min temperature and humidity of the
selected channel will be shown. Also the time and date of recording this temperature will
be displayed.
Outdoor icon
Time and date
of recording
the Max
temperature
Channel No.
Ma
temperature Max icon
Max humidity
4. Press one more time the MIN/ MAX button to advance to the indoor Max/ Min temp
display.
80
Note: The time of recording the minimium or maximum humidity is not recorded.
RESETTING THE OUTDOOR MAXIMUM/ MINIMUM RECORDS
Note:
It is required to reset the outdoor max/ min records of different channels separately.
The outdoor minimum and maximum records are to be reset separately.
1. In normal display mode, press the CH button to select a channel. The channel
Identification No. (channel No.) will be displayed near the outdoor temperature reading.
Note: The transmitter number will only be displayed if more than one transmitter is
applied.
2. Press the MIN/MAX button once. The "max" icon will be displayed.
3. Press the SET button, this will reset the outdoor maximum temperature, humidity and
time (of recording the temp) to the current value.
4. Press MIN/ MAX button once more to show the minimum data. The "min" icon will be
displayed.
5. Press the SET button, this will reset the outdoor minimum temperature , humidity and
time (of recording the temp) record to the current value.
6. Press three more times the MIN/MAX key to return to the normal display.
DISPLAY OF INDOOR MAXIMUM AND MINIMUM RECORDS:
1. In normal display mode, press the MIN/MAX button three times. The maximum indoor
temperature and humidity will be shown in the bottom section of LCD. Also the time and
date of recording this temperature will be displayed.
2. Then press the MIN/MAX button one more time, the minimum indoor temperature and
humidity will be shown in the bottom section of LCD. Also the time and date of recording
this temperature will be displayed:
Indoor icon
Time and date of
recording the Min
temperature
Min temperature
Min icon
Min humidity
81
82
3. Press one more time the MIN/ MAX button to go back to the normal display.
Note: The time of recording the minimium or maximum humidity is not recorded.
RESETTING THE INDOOR MAXIMUM/ MINIMUM RECORDS
1. In normal display mode, press the MIN/MAX button three times to advance to the indoor
MAX display.
2. Press the SET key once, this will reset the currently shown indoor maximum temp ,
humidity and time (of recording the temp) to the current time, date and temperature.
3. Press the MIN/MAX button once more to advance to the indoor MIN display.
4. Press the SET key once, this will reset the currently shown indoor minimum temp ,
humidity and time (of recording the temp) to the current time, date and temperature.
5. Press the MIN/MAX button once more to return to the normal display.
DAILY MIN AND MAX OUTDOOR TEMPERATURE DISPLAY
This weather station will display the daily maximum and minimum outdoor temperature for each
outdoor channel, at the bottom of the LCD, in normal display.
Channel No.
Max daily temp of
the channel
Min daily temp
of the channel
To view the daily max and min temperature of another channel, user shall press the CH key in
normal display.
Note:
The daily minimum temperature record is reset automatically at 8:00 pm and the daily maximum
temperature is reset automatically at 8:00 am every day.
868 MHz RECEPTION
The Weather station should receive the temperature data within 5 minutes after set-up. If the
outdoor data signal cannot be received 5 minutes after setting up or in normal mode the signal
reception is "disturbed" continuously, the outdoor display will show “- - -” . Then user shall check
the following points:
83
MOUNTING
POSITIONING THE WEATHER STATION:
The Weather Station may be hung onto wall easily or free standing.
To wall mount
Choose a sheltered place. Avoid direct rain and sunshine.
85
received from the d
Before wall mounting, please check that the outdoor temperature and humidity values can be
esired locations.
1. Fix a screw (not supplied) into the desired wall, leaving the head
extended out the by about 5mm.
2. Hang the station onto the screw. Remember to ensure that it locks
into place before releasing.
Free standing
With the stand, the weather station can be placed onto any flat surface.
86
POSITIONING THE THERMO-HYGRO TRANSMITTER:
The Transmitter is supplied with a holder that may be attached to a wall with the two screws
supplied. The Transmitter can also be position on a flat surface by securing the stand to the
bottom to the Transmitter.
87
To wall mount:
1. Secure the bracket onto a desired wall using the screws and plastic
anchors.
2. Clip the remote thermo-hygro transmitter onto the bracket.
Note:
Before permanently fixing the transmitter wall base, place all units in the desired locations to
check that the outdoor temperature reading is receivable. In event that the signal is not received,
relocate the transmitters or move them slightly as this may help the signal reception.
CARE AND MAINTENANCE:
Extreme temperatures, vibrations and shocks should be avoided as these may cause
damage to the unit and give inaccurate forecasts and readings.
88
89
When cleaning the display and casings, use a soft damp cloth only. Do not use solvents or
scouring agents as they may mark the LCD and casings.
Do not submerge the units in water. Furthermore, fix all parts in place where the units are
adequately protected against moisture and rain.
Immediately remove all low powered batteries to avoid leakage and damage. Replace
only with new batteries of the recommended type.
Do not make any repair attempts to the unit. Return them to their original point of
purchase for repair by a qualified engineer. Opening and tampering with the unit may
invalidate their guarantee.
Do not expose the units to extreme and sudden temperature changes, this may lead to
rapid changes in forecasts and readings and thereby reduce their accuracy.
SPECIFICATIONS:
Temperature measuring range:
Indoor : -9.9ºC to +59.9ºC with 0.1ºC resolution (14.1°F to +139.8°F with 0.2°F
resolution); “OF.L” displayed if outside this range
Outdoor : -39.9ºC to +59.9ºC with 0.1ºC resolution (-39.8°F to +139.8°F with 0.2°F
resolution); “OF.L” displayed if outside this range
Relative humidity measuring range:
Indoor: 1% to 99% with 1% resolution (displays - -” when lower than 1 %;
displays "99" % if higher than 99 %)
90
Outdoor: 1% to 99% with 1% resolution (displays “ ”1 when lower than 1 %;
displays "99" % if higher than 99 %)
Indoor temperature checking interval : every 15 seconds
Indoor humidity checking interval : every 20 seconds
Outdoor data reception : every 4 seconds
Power supply:
Weather station : 2 x AA, IEC, LR6, 1.5V
Thermo-hygro transmitter : 2 x AA, IEC, LR6, 1.5V
Battery life cycle (Alkaline batteries recommended)
Weather station : Approximately 24 months
Thermo-hygro transmitter : Approximately 24 months
Dimensions (L x W x H)
Weather station : 122.8 x 23.1 x 169.7 mm (4.83" x 0.91" x 6.68")
Thermo-hygro transmitter : 38.2 x 21.2 x 128.3 mm (1.50" x 0.83" x 5.05")


Produkt Specifikationer

Mærke: Techno Line
Kategori: Vejrstation
Model: WS 9624 IT

Har du brug for hjælp?

Hvis du har brug for hjælp til Techno Line WS 9624 IT stil et spørgsmål nedenfor, og andre brugere vil svare dig




Vejrstation Techno Line Manualer

Techno Line

Techno Line WS 9620 Manual

27 December 2024
Techno Line

Techno Line WS 9310 Manual

27 December 2024
Techno Line

Techno Line WS 9135 Manual

27 December 2024
Techno Line

Techno Line WS 6870 Manual

27 December 2024
Techno Line

Techno Line WS 9450 Manual

27 December 2024
Techno Line

Techno Line WS 9257 Manual

27 December 2024
Techno Line

Techno Line WS 9125 Manual

27 December 2024
Techno Line

Techno Line WS 9060 Manual

27 December 2024
Techno Line

Techno Line MA 10920 Manual

27 December 2024

Vejrstation Manualer

Nyeste Vejrstation Manualer

Bresser

Bresser VentAir V Manual

14 Marts 2025
Irox

Irox Aqua Manual

9 Marts 2025
Irox

Irox Easy 49 Manual

9 Marts 2025
Irox

Irox Comfo-X Manual

9 Marts 2025
Irox

Irox Easy 79 Manual

9 Marts 2025
Irox

Irox ETG38 Manual

9 Marts 2025
Irox

Irox ETS50 Manual

9 Marts 2025
Irox

Irox ETS69 Manual

9 Marts 2025
Irox

Irox HBR553 Manual

9 Marts 2025
Irox

Irox HBR558 Manual

9 Marts 2025