5020-0105 CO2ntrol Life - Operating Instructions
1. Green LED Display (<800ppm)
2. Yellow LED Display (800-1200ppm)
3. Red LED Display ( >1200ppm & buzzer alarm)
4. Mute Button
5. Power lnlet
6. Housing Stand
7. Screw Position
EMC/RFI
Readings may be affected if the uni! is operated within radio frequency electromagneticeld strength of approximately 3 volts per meter, but the performance of
the instrument will not be permanently affected. Note: Under the electromagnetic eld of 3V/m, the reading will not meet the specication.
Product Overview
Thank you for selecting 5020-0105 desktop C0 2 monitor, 5020-0105 C02 monitor is smart, compact and easy-to-use. In addition to measuring the C0 2
concentration, 5020-0105 can also measure the ambient temperature and the relative humidity (CO 2+Temp.+RH). This product is developed to detect
the presence of C02 in ambient air and help people to take care of lndoor Air Quality. 5020-0105 can be widely used in the ofce building, school,
exhibition hall, shopping mall, meeting room, tness center, restaurant and other public places where personal comfort, healthy is important.
Features:
· Three different LED display shows the current lndoor Air Quality
· Press MUTE button for alarm on/off.
· Built in the LCD Backlight for easy reading in the dark.
Warnings:
· Please take off the AC power adapter and store it weil when this C0 2 monitor left idle for long.
· This C02 monitor is for harne use, not suitable for certifying the lest results.
· lf use this C02 monitor for testing, 5020-0105 does not guarantee the lest results.
1. 2 min. warm-up time when rst time power.
2. The LCD shows 4 bars with 1sec blank cycle during warm-up
3. The MUTE button is disabled during warm-up
4. The device shows the C02 readin after warm-u
Warm-Up Time: 2 MIN.
Press MUTE button to select buzzer on/off. lf the „MUTE“function is off, while C0 2
concentration exceed the alarm level (>1200 ppm), there will be a buzzer.
Note: The device settin with alarm is buzzer on when power on rst time, user can
set the alarm on/off under MUTE function
Usin the MUTE function:
Safety Instructions:
Warning: Your safety is very important to us .To ensure to use the product correctly and safely, we would like to draw your attention to read the warning
and entire User Manual before using the product. These are important safety information and should be observed at all times.
1. Check if the contents of the package are undamaged and complete.
2. For cleaning the instrument please do not use an abrasive cleaner only a dry or moist piece of soft cloth. Do not allow any liquid into the interior
of the device.
3. Please store the measuring instrument in a dry and clean place.
4. Avoid any force like shocks or pressure to the instrument.
5. No responsibility is taken for irregular or incomplete measuring values and their results, the liability for subsequent damages is excluded!
6. Do not keep the product under the hol and moisture environment. Keep the product away from the heat source or near water.
7. Please use only the included power adaptor. lmproper power adaptor or power sources can cause serious damage to the product, or result in injury
or death to the user.
!