TriStar AC-5670 Airconditioner - Aircooler Manual

TriStar Klimaanlæg - Luftkøler AC-5670 Airconditioner - Aircooler

Læs nedenfor 📖 manual på dansk for TriStar AC-5670 Airconditioner - Aircooler (11 sider) i kategorien Klimaanlæg - Luftkøler. Denne guide var nyttig for 22 personer og blev bedømt med 4.5 stjerner i gennemsnit af 2 brugere

Side 1/11
AC-5670
EN | Instruction manual
NL | Gebruiksaanwijzing
FR | Mode d’emploi
DE | Bedienungsanleitung
ES | Manual de usuario
PT | Manual de utilizador
IT | Manuele utente
SV | Bruksanvisning
PL | Instrukcja obsługi
CS | Návod na použití
SK | Návod na použitie
PARTS DESCRIPTION / ONDERDELENBESCHRIJVING / DESCRIPTION DES PIÈCES / TEILEBESCHREIBUNG /
DESCRIPCIÓN DE LAS PIEZAS / DESCRIÇÃO DOS COMPONENTES / DESCRIZIONE DELLE PARTI /
BESKRIVNING AV DELAR / OPIS CZĘŚCI / POPIS SOUČÁSTÍ / POPIS SÚČASTÍ
1
5
3
9
12
11
6
4
7
810
13
WWW.TRISTAR.EU
Tristar Europe B.V. | Jules Verneweg 87
5015 BH Tilburg | The Netherlands
Wireless technology: Wi-Fi
Operating frequency: 2,4 Ghz
Max. radio-frequency power: 20.5dBm
ENInstruction manual
SAFETY
Please read this user’s manual carefully to
ensure proper use, maintenance and
installation.
By ignoring the safety instructions the
manufacturer cannot be held responsible for
the damage.
The appliance is for indoor use only.
Do not use the unit on a socket that is
damaged or that has not been installed
correctly.
Do not use the unit:
near a source of fire.
in an area where oil is likely to splash.
in an area exposed to direct sunlight.
in an area where water is likely to splash.
near a bath, a shower or a swimming pool.
Never insert your fingers or objects into the air
outlet. Take special care to warn children of
these dangers.
Keep the unit upright during transport and
storage.
Before cleaning the unit, always turn off or
disconnect the power supply.
Always turn off and disconnect the power
supply before moving the unit.
WARNING: To avoid the risk of fire, do
not cover the unit.
All the unit sockets must comply with the local
electric safety requirements. If necessary
please check.
If the power cord is damaged, it must be
replaced by the manufacturer, service agent
or qualified person(s) in order to avoid a
hazard.
This appliance can be used by children aged
8 years and above, persons with reduced
physical, sensory, and mental capabilities or
persons with a lack of experience and
knowledge if they have been given correct
supervision or instruction concerning the use
of the appliance in a safe way and understand
the hazards involved. Children should not play
with the appliance. Cleaning and user
maintenance should not be carried out by
children without supervision.
This appliance is only to be used for
household purposes and only for the purpose
it is made for.
• Notes:
In the case of any damage, please disconnect
the power supply and contact the dealer or a
designated repair shop.
In any case, the power cord shall be firmly
grounded.
To avoid the possibility of danger, if the power
cord is damaged, please disconnect the
power supply. It must be replaced by the
dealer or a designated repair shop.
Warning
Please use the recommended defrosting and
cleaning process from the manufacturer only.
Do not accelerate the defrosting or cleaning
process in any other way.
The appliance shall be stored in a room
without continuously operating ignition
sources (for example: open flames , an
operating gas appliance or an operating
electric heater).
Do not pierce or burn.
Be aware that refrigerants may not contain an
odor.
The appliance should be installed, operated
and stored in a room with a floor area larger
than X m2. (X=4 for 7000Btu/h)
Only contact an authorized service technician
for repair or maintenance of this unit.
Do not pull , deform or modify the power
supply cord or immerse in water . Pulling or
misuse of the power supply cord could result
in damage to the unit and cause an electrical
shock.
Compliance with national gas regulations
should be observed.
Keep ventilation openings clear of
obstructions.
Any person who is involved with working on or
opening a refrigerant circuit should hold a
current valid certificate from an industry
accredited assessment authority which
authorizes their competence to handle
refrigerants safely in accordance with an
industry recognized assessment specification.
Do not stop the unit by pulling out the power
plug whilst in operation as this may cause an
electric shock or fire due to heat generation
unless strange sounds are heard or if strange
smells or smoke appear from the unit.
Specific information regarding appliances with R 290 refrigerant gas.
Thoroughly read all of the warnings.
When defrosting and cleaning the appliance ,
do not use any tools other than those
recommended by the manufacturing company.
The appliance should not be stored in a room
with continuously operating ignition sources (for
example: open flames , an operating gas
appliance or an operating electric heater).
Do not puncture and do not burn.
This appliance contains Y g (see rating label
back of unit ) of R290 refrigerant gas.
R290 is a refrigerant gas that complies with the
European directives on the environment. Do not
puncture any part of the refrigerant circuit.
If the appliance is installed, operated or stored
in a non-ventilated area, the room must be
designed to prevent to the accumulation of
refrigerant leaks that could result in a fire risk or
explosion due to ignition of the refrigerant
caused by electric heaters, stoves, or other
sources of ignition.
The appliance must be stored in such a way as
to prevent mechanical failure.
Individuals who operate or work on the
refrigerant circuit must have the appropriate
certification issued by an accredited
organization that ensures competence in
handling refrigerants according to a specific
evaluation recognized by associations in the
industry.
Repairs must be performed based on the
recommendation from the manufacturing
company. Maintenance and repairs that require
the assistance of other qualified personnel must
be performed under the supervision of an
individual specified in the use of flammable
refrigerants.
Batteries
Do not expose the battery to high temperatures
or direct sunlight. Never throw batteries into the
fire. There is a danger of explosion!
Keep batteries away from children. Batteries are
not a toy!
Do not open the batteries by force.
Avoid contact with metallic objects.(Rings, nails,
screws et cetera) there is a danger of short-
circuiting!
As a result of a short-circuit batteries may heat
up consider-ably or even catch fire. this may
result in burns.
For your safety the battery poles should be
covered with adhesive strips during transport.
Do not touch a ruptured and/or leaking battery.
If the liquid from the battery gets into your eyes,
rinse your eyes as soon as possible with clean
water, without rubbing your eyes. Immediately
go to the hospital. If it is not treated properly, it
can cause eye problems.
Refrigerant
(CE) N 842/2006: This unit contains the refrigerant R290. The amount of
refrigerant is less than 1kg, and is in a closed cooling circuit. The coolant
does have zero ozone depletion potential, but is a so-called greenhouse
gases under the Kyoto Protocol and may thus contribute to global
warming, if it is released to the atmosphere. Therefore only trained
technicians with refrigerant certificate make a filling or emptying. Your
appliance does not have be refilled with refrigerant if used properly and
has an undamaged coolant circuit. GWP: R290: 3
This product complies with conformity requirements of the applicable
European regulations or directives.
Waste electrical products should not be disposed of with household waste.
Please recycle where facilities exist. Check with your local Authority or
local store for recycling advice.
PARTS DESCRIPTION
1. Air inlet 8. Hose connector (window end)
2. Air filter 9. Hot-air exhaust hose
3. Control panel 10. Hose connector (Air conditioner end)
4. Power cord 11. Windows slider kit + fixing plugs
5. Air outlet 12. Remote control
6. Castor 13. Batteries
7. Drainage hole
FUNCTION OF CONTROL PANEL
1. Power (on/off) button
2. Temperature buttons
3. Mode button
4. Fan speed adjustment button
5. Timer (on/off) button
REMOTE CONTROL
1. Power (on/off) button
2. Timer button
3. Mode button
4. Fan speed adjustment button
5. Temperature up (+) button
6. Temperature down (-) button
2xAAA size batteries are required.
Ensure batteries are inserted in the correct direction.
When replacing, ensure both batteries are changed simultaneously.
BEFORE THE FIRST USE
Before starting operations in this section:
Find a place where there is power supply nearby.
Install the exhaust hose and adjust the window position well.
The supplied small white clips must be mounted on the window kit.
Insert the power cord into a grounded AC220-240V~/50Hz socket.
Press the power button to turn on the air-conditioner.
Set the temperature range: 16°C-31°C.
Check whether the exhaust hose has been mounted properly.
When using functions on cooling and dehumidifying, allow at least 3
minutes between powering off and powering on.
USING THE ON DEVICE BUTTONS
Cooling operation
Press the “Mode“ button till the “Cool“ icon appears.
Press the + <Temperature up> or - <Temperature down> button to select
a desired room temperature.
Allow around 5 minutes for the cooling to start.
Press the “Fan speed” button to adjust airflow speed.
Dehumidifying operation
Press the “Mode“ button until the “Dehumidify” icon appears.
The temperature will automatically be selected.
The fan speed will automatically be selected.
Fan operation
Press the “Mode“ button till the “Fan“ icon appears.
Press the “Fan speed” button to adjust airflow speed.
Timer operation
Timer ON setting
When the air-conditioner is OFF, press the “Timer“ button and select a
desired ON time and adjust by using the <Temperature up> and
<Temperature down> buttons.
The ON time can be adjusted to anytime in 0-24 hours.
Timer OFF setting
When the air-conditioner is ON, press the “Timer“ button and select a
desired OFF time and adjust by using the <Temperature up> and
<Temperature down> buttons.
The OFF time can be adjusted to anytime in 0-24 hours.
Drainage
After a lengthy operation and before storage, you will need to drain the
water that has been collected. Please prepare a suitable location or tray
to collect the water and remove the rubber stop from the drainage hole at
the bottom of the unit. The water will then begin to drain. After this has
stopped, you can insert the drain stop.
Internal Tank Water Full Alarm Function
The inner water tank in the air-conditioner has one water level safety
switch that controls the water level. When the water level reaches an
anticipated height, the water full indicator lamp lights up. Follow previous
steps to drain the water.
INSTALLATION
The air-conditioner should be installed on a flat and stable surface. Do
not block the air outlet and allow at least 30cm around the unit.
Socket wiring should be in accordance with the local electric safety
requirements.
Exhaust Hose Installation
Twist both ends of the hot-air exhaust hose(9) into the hose connector
window end(8) and the hose connector air conditioner end(10).
Insert the hose connector air conditioned end(10) into the openings at
the back of the air conditioner.
Fix the hose connector window end(8) to the nearest windowsill.
Window Slider Kit Installation
Adjust the width (picture 1) or height (picture 2) of the windows slider(11)
to fit the window opening and fixate the position of the windows slider(11)
with the fixing plugs.
Slide the window up to the slider.
USING THE APPLIANCE WITH CLIMATE APP
The appliance can be used manually with its built-in controls, remote
control or you can use a smart phone or voice to control it. Before you
begin, ensure the Homewizard Climate app is downloaded. The
Homewizard Climate app is available on Android and iOS.
Pair your appliance to HomeWizard Climate app
Make sure the appliance is powered.
Open HomeWizard Climate APP.
Create an account or if you already have a HomeWizard account, please
log in using those details.
Click "Add new Climate Device" to add a new device.
Select the device you want to connect.
Follow the instructions on the app to connect the appliance.
TABLE AC WIFI AC-5670 & AC-5670BS
Information requirements for single and double duct air
conditioners P
Information to identify the model(s) to which the information relates to:
Description Symbol Value Unit
Rated capacity for cooling Prated for
cooling 2.10 kW
Rated capacity for heating Prated for
heating N/A kW
Rated power input for cooling Peer 0.807 kW
Rated power input for heating Pcop N/A kW
Rated Energy efficiency ratio EERd 2.60 -
Rated Coefficient of
performance COPd N/A -
Information to identify the model(s) to which the information relates to:
Description Symbol Value Unit
Power consumption in
thermostat-off mode Pto - W
Power consumption in standby
mode Psb 0,5/2,0
(with Wi-Fi) W
Electricity consumption of
single/double duct appliances
(indicate for cooling and heating
separately)
Qsd SD: 0.807
(Cooling) kWh/h
Sound power level Lwa 65 dB(A)
Global warming potential GWP 3 kgCO²e
q.
CLEANING MAINTENANCE
Before cleaning, disconnect the unit from any electric supply outlet.
First clean the surface with a neutral detergent and wet cloth, and then
wipe it with a dry cloth.
Do not use gasoline or other chemicals to clean the unit.
Do not wash the unit directly.
Air filter
The air filter should be cleaned once every two weeks.
Open the air inlet grille and take off air filter.
Clean the air filter with neutral detergent in lukewarm 40°C water and
allow to dry (not in direct sunlight).
Re-install the air filter into the inlet grille.
TROUBLESHOOTING
Troubles Possible Causes Suggested Remedies
The unit
does not
start when
pressing
power
button.
Water full indicator lamp
blinks and water tank is
full.
Room temperature is
higher than the setting
temperature.(Electric
heating mode)
Room temperature is
lower that the setting
temperature.(Cooling
mode)
Drain the water out of the
water tank.
Adjust the temperature.
The unit
doesn’t
cool
enough.
The doors or windows are
not closed.
There are heat sources
inside the room.
Hot air exhaust hose is not
connected or blocked.
Temperature setting is too
high.
Air inlet in blocked.
Make sure all the windows
and doors are closed.
Remove the heat sources if
possible.
Connect or clean the hot air
exhaust hose.
Reset the temperature.
Clean the air inlet.
Noisy. The ground is not level or
not flat enough.
The sound comes from the
flowing of the refrigerant
inside the air conditioner.
Place unit on a flat, level
ground if possible.
E0 Code. Room temperature sensor
failed. Replace room temperature
sensor.
E1 Code. Condenser temperature
sensor failed. Replace condenser
temperature sensor.
E2 Code. Water tank full. Please empty the water tank.
E3 Code. Evaporator temperature
sensor failed. Replace evaporator
temperature sensor.
E4. Code Water tank full. Please empty the water tank.
THE PRODUCT OR EQUIPMENT CONTAINS FLUORINATED
GREENHOUSE GAS.
Art.nr. AC-5670
Coolant: R290
Quantity in kg: 0.14
Global Warming Potential: 3
CO2 Equivalent in tonnes: 0.00042
DECLARATION OF CONFORMITY
Hereby, Smartwares Europe declares that the radio equipment type
AC-5670 is in compliance with Directive 2014/53/EU
The full text of the EU declaration of conformity is available at the
following internet address: www.princesshome.eu/doc
ENVIRONMENT
This appliance should not be put into the domestic garbage at the
end of its durability, but must be offered at a central point for the recycling
of electric and electronic domestic appliances. This symbol on the
appliance, instruction manual and packaging puts your attention to this
important issue. The materials used in this appliance can be recycled. By
recycling of used domestic appliances you contribute an important push to
the protection of our environment. Ask your local authorities for information
regarding the point of recollection.
The European directive for batteries (2006/66/EC) states that it is not
permitted to throw batteries away with the household waste. They may
contain substances which are harmful to the environment. Empty batteries
can be handed over to a local, public collection point or a local recycling
centre. To avoid overheating as a result of a short circuit, lithium batteries
must be removed from the product and the poles must be protected using
insulation tape or some other means against short-circuiting.
You can find all available information and spare parts at www.tristar.eu!
NLGebruiksaanwijzing
VEILIGHEID
Lees deze gebruiksaanwijzing zorgvuldig door
voor een correct(e) gebruik, onderhoud en
installatie.
Als u de veiligheidsinstructies negeert, kan de
fabrikant niet verantwoordelijk worden
gehouden voor de mogelijke schade.
Het apparaat is alleen geschikt voor gebruik
binnenshuis.
Sluit het apparaat niet aan op een stopcontact
dat beschadigd is of niet correct is
geïnstalleerd.
Gebruik het apparaat niet:
in de buurt van vuur.
in een gebied met een grote kans op spattende
olie.
in een gebied dat wordt blootgesteld aan direct
zonlicht.


Produkt Specifikationer

Mærke: TriStar
Kategori: Klimaanlæg - Luftkøler
Model: AC-5670 Airconditioner - Aircooler

Har du brug for hjælp?

Hvis du har brug for hjælp til TriStar AC-5670 Airconditioner - Aircooler stil et spørgsmål nedenfor, og andre brugere vil svare dig




Klimaanlæg - Luftkøler TriStar Manualer

Klimaanlæg - Luftkøler Manualer

Nyeste Klimaanlæg - Luftkøler Manualer