Preface
Thank you for purchasing this brand new product. In order to use this product safely and
correctly, please read this manual thoroughly, especially the safety notes.
After reading this manual, it is recommended to keep the manual at an easily
accessibleplace, preferably close to the device, for future reference.
Limited Warranty and Liability
Uni-Trend guarantees that the product is free from any defect in material and workmanship
within one year from the purchase date. This warranty does not apply to damages
caused by accident, negligence, misuse, modification, contamination or improper handling.
The dealer shall not be entitled to give any other warranty on behalf of Uni-Trend. If you
need warranty service within the warranty period, please contact your seller directly.
Uni-Trend will not be responsible for any special, indirect, incidental or subsequent
damage or loss caused by using this device.
I. Appearance
Short press Long pressDescription
Distance button
Function button
Log button
Unit/Reference button
Add/Subtract button
Sound button
Clear/Off button
Tripod mounting hole
(size: ¼ inch)
Battery compartment
Enter single
measurement mode
Switch measurement
function
Scroll up log
Switch reference
Add
Turn on/off buzzer
Delete log/Return
after clearance
N/A
N/A
Power on meter (in the
off state)/Enter continuous
measurement mode
N/A
Save log
Switch unit
Subtract
N/A
Power off meter
N/A
N/A
No.
1
2
3
4
5
6
7
8
9
Single/Continuous measurement
Area measurement
Triangular area measurement
Volume measurement
Direct Pythagoras measurement
Indirect Pythagoras measurement
Indirect Pythagoras measurement
Auto horizontal measurement
Auto vertical measurement
II. Measurement Function Icons
III. Operating Instructions
Turn on the meter and it will enter the single measurement mode by default. Press the
button and the flashing edge is the edge to be measured.
Please pay attention to the measurement reference. The starting point will be different
when different reference points are selected.
This function will stop automatically after 5 minutes of continuous
measurement.
3. Area Measurement
1) Press the button to switch to the area
measurement .
2) According to the flashing edge, point the laser at the first
point of the target, and press the button to measure
the first edge (length).
3) Point the laser at the second point of the target, and press
the button again to measure the second edge (width).
4) The calculation results of the length, width, circumference
and area will be displayed on the screen successively.
4. Triangular Area Measurement
1) Press the button to switch to the triangular area
measurement .
2) According to the flashing edge, point the laser at the first
point of the target, and press the button to measure
first edge. the
3) Point the laser at the second point of the target, and press
the button again to measure the second edge.
4) Point the laser at the third point of the target, and press
the button again to measure the third edge.
5) The calculation result of the triangular area will be displayed
at the bottom of the screen.
5. Volume Measurement
1) Press the button to switch to the volume
measurement .
2) According to the flashing edge, point the laser at the first
point of the target, and press the button to measure the
first edge (length).
3) Point the laser at the second point of the target, and press
the button to measure the second edge (width).
4) Point the laser at the third point of the target, and press
the button again to measure the third edge (height).
5) The volume calculation result will be displayed at the
bottom of the screen.
The measurement reference in this manual refers to the rear reference.
1. Single Measurement
Turn on the meter and it will enter the single measurement mode by default. Point the
laser at the measurement target, then press the button and the measurement result
will be displayed at the bottom of the screen.
2. Continuous Measurement (Max/Min Measurement)
This function can be used to measure the diagonal of a house, look for levels, stake
out, etc.
Long press the button to enter the continuous measurement mode. Point the laser
at the measurement target, and then press the button to stop measuring. The MIN/
MAX/current measured value will be displayed on the screen successively.
6. Pythagoras Measurement
All the Pythagoras measurement can be applied to different
plane measurement, as long as the right-angle side is
perpendicular to the object being measured.
Note: In Pythagorean Theorem, the right-angle side cannot
be longer than the hypotenuse; otherwise a calculation error
will occur.
1) Press the button to switch to the direct Pythagoras
measurement .
2) According to the flashing edge, point the laser at the first
point of the target, and press the button to measure the
hypotenuse.
3) Rotate to the direction perpendicular to the target with the
set reference as center, and press the button to measure
one right-angle side.
4) The calculation result of the other right-angle side is
displayed at the bottom of the screen.
P/N:110401109313X


Produkt Specifikationer

Mærke: Uni-T
Kategori: Fjernbetjening
Model: LM100G

Har du brug for hjælp?

Hvis du har brug for hjælp til Uni-T LM100G stil et spørgsmål nedenfor, og andre brugere vil svare dig




Fjernbetjening Uni-T Manualer

Uni-T

Uni-T LM60Mi Manual

1 September 2024
Uni-T

Uni-T LM60E Manual

31 August 2024
Uni-T

Uni-T LM120PRO Manual

31 August 2024
Uni-T

Uni-T LM200C Manual

31 August 2024
Uni-T

Uni-T LM100D Manual

31 August 2024
Uni-T

Uni-T LM100EX Manual

31 August 2024
Uni-T

Uni-T LM100G Manual

31 August 2024
Uni-T

Uni-T LM40T Manual

31 August 2024
Uni-T

Uni-T LM120A Manual

31 August 2024
Uni-T

Uni-T LD50 Manual

31 August 2024

Fjernbetjening Manualer

Nyeste Fjernbetjening Manualer

Morel

Morel MPS-R1 Manual

18 November 2024
One For All

One For All URC 2110 Manual

16 November 2024
One For All

One For All KE4910 Manual

16 November 2024
Canon

Canon BG-E20 Manual

12 Oktober 2024
DSC

DSC WS4949 Manual

8 Oktober 2024
Neewer

Neewer RT112 Manual

7 Oktober 2024
Neewer

Neewer RT113 Manual

7 Oktober 2024