SPECIFICATION
MODEL
DC VOLTAGE
RATED CURRENT
RATED POWER
OUTPUT
VOLTAGE ADJ. RANGE Note.6
CURRENT ADJ. RANGE
LINE REGULATION
LOAD REGULATION Note.8
SETUP, RISE TIME Note.9
HOLD UP TIME (Typ.)
VOLTAGE RANGE Note.5
FREQUENCY RANGE
POWER FACTOR (Typ.)
EFFICIENCY (Typ.)
AC CURRENT (Typ.)
INPUT
INRUSH CURRENT (Typ.)
LEAKAGE CURRENT
SAFETY STANDARDS Note.7
WORKING TEMP.
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
MTBF
DIMENSIONOTHERS
NOTE
PACKING
OVER CURRENT Note.4
OVER VOLTAGE
OVER TEMPERATURE
Can be adjusted by internal potentiometer A type and C type only
1000ms,80ms/115VAC 500ms,80ms/230VAC at full load
15ms at full load 230VAC /115VAC
90 ~ 305VAC 127 ~ 431VDC
47 ~ 63Hz
PF>0.98/115VAC, PF>0.95/230VAC at full load (Please refer to "Power Factor Characteristic" curve)
4A / 115VAC 2A / 230VAC 1.2A / 277VAC
<0.75mA / 277VAC
95 ~ 108%
Protection type : Constant current limiting, recovers automatically after fault condition is removed
Compliance to EN55015, EN55022 (CISPR22) Class B, EN61000-3-2 Class C ( 50% load) ; EN61000-3-3
Compliance to EN61000-4-2,3,4,5,6,8,11, EN61547, EN55024, light industry level (surge 4KV), criteria B
-40 ~ +70 (Refer to "Derating Curve")
20 ~ 95% RH non-condensing
-40 ~ +80 , 10 ~ 95% RH
± ℃ 0.03%/ (0 ~ 50 )
10 ~ 500Hz, 5G 12min./1cycle, period for 72min. each along X, Y, Z axes
207.9K hrs min. MIL-HDBK-217F (25 )
244.2*68*38.8mm (L*W*H)(HLG-240H-Blank/A/B) 251*68*38.8mm (L*W*H)(HLG-240H-C)
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Rippl noise are measured at 20MHz of bandwidth by usine & g a 12" twisted h a 0.1uf & pair-wire terminated wit 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. Please refer to "DRIVING METHODS OF LED MODULE".
5. Derating may be needed under low input voltages. Please check the for more details. static characteristics
6. A type and C type only.
7. Safety and EMC design refer to EN60598-1, subject 8750(UL), CNS15233, GB7000.1, FCC part18.
8. Length of set up time is measured at cold first start. Turning ON/OFF the power supply may lead to increase of the set up time.
9. The power supply is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the
complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again.
10. Refer to warranty statement.
11. To fulfill requirements of the latest ErP regulation for lighting fixtures, this LED power supply can only be used behind a switch without permanently
connected to the mains.
1.3Kg; 12pcs/16.6Kg/0.84CUFT(HLG-240-Blank/A/B) 1.23Kg; 12pcs/15.8Kg/1.16CUFT(HLG-240-C)
Protection type : Shut down and latch off o/p voltage, re-power on to recover
240W Single Output Switching Power Supply
Universal AC inpu Full range (up to 305VAC)t /
Built-in active PFC function
Protections: Short circui Over curren Over voltag Over temperature t / t / e /
Cooling by free air convection
OCP point adjustable through output cable or internal potentiometer
IP67 / IP65 design for indoor or outdoor installations
Three in one dimming function (1~10Vdc or PWM signal or resistance)
Suitable for LED lighting and street lighting applications
Compliance to worldwide safety regulations for lighting
Suitable for dry / damp / wet locations
Type HL for use in class , Divisio hazardous(Classified) location luminairesn 2
7 years warranty (Note.10)
Features :
H LG - 24 0H s er i e s
RIPPLE & NOISE (max.)
Note.2
VOLTAGE TOLERANCE Note.3
ENVIRONMENT
SAFETY &
EMC
PROTECTION
Shut down o/p voltage, recovers automatically after temperature goes down
F
110
SELV
IP65 IP67
SHORT CIRCUIT
Hiccup mode, recovers automatically after fault condition is removed
Blank : IP67 rated. Cable for I/O connection.
90% 90% 91.5% 92.5% 92.5% 92.5% 93%92.5% 93.5%
±2.5%
8 ~ 16A
±2.0%
7.5 ~ 15A
±1.0%
6 ~ 12A
±1.0%
5 ~ 10A
±1.0%
4 ~ 8A
±1.0%
3.3 ~ 6.7A
±1.0%
2.5 ~ 5A
± ± ± ± ±0.5% 0.5% 0.5% 0.5% 0.5% ±0.5% ±0.5%
±2.0% ± ± ± ±1.5% 1.0% 0.5% 0.5% ±0.5% ±0.5%
±1.0%
2.23 ~ 4.45A
±0.5%
±0.5%
±1.0%
2.86 ~ 5.72A
±0.5%
±0.5%
HLG-240H-12
HLG-240H-15
HLG-240H-20
HLG-240H-24
HLG-240H-30
HLG-240H-36
HLG-240H-48
12V
6 ~12V
15V
7.5 ~ 15V
20V
10 ~ 20V
24V
12 ~ 24V
30V
15 ~ 30V
36V
18 ~ 36V
48V
24 ~ 48V
16A 15A 12A 10A 8A 6.7A 5A
192W 225W 240W 240W 240W 241.2W 240W
150mVp-p 150mVp-p
14 ~ 16V
150mVp-p
18.6 ~ 21.4V
150mVp-p
22.4 ~ 25.6V
200mVp-p
28 ~ 32V
250mVp-p
33.5 ~ 38.5V
250mVp-p
44.8 ~ 51.2V11.2 ~ 12.8V
HLG-240H-54
54V
27 ~ 54V
4.45A
240.3W
350mVp-p
50 ~ 57V
HLG-240H-42
42V
21 ~ 42V
5.72A
240.24W
250mVp-p
39 ~ 45V
EMC IMMUNITY
EMC EMISSION
B : IP67 rated. Constant current level adjustable through output cable with 1~10Vdc or 10V PWM signal or resistance.
13.5 ~ 18V 17.5 ~ 21.5V 23.5 ~ 27.5V 27 ~ 34V 33 ~ 39V 43 ~ 49V 55 ~ 63V48 ~ 54V 60 ~ 67V
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
I/P-O/P:3.75KVAC I/P-FG:2KVAC O/P-FG:1.5KVAC
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 / 70% RH
CONSTANT CURRENT REGION Note.4
HLG-240H-12 A
A : IP65 rated. Output voltage and constant current level can be adjusted through internal potentiometer.
C : Terminal block for I/O connection. Output voltage and constant current level can be adjusted through internal
potentiometer.
D (option, safety pending IP67 rated. Timer dimming function, contact MEAN WELL for details.) :
UL1012, CAN/CSA-C22.2 No. 107.1-01, UL8750(typeHL), CSA C22.2 No. 250.0-08, TUV EN61347-1, EN61347-2-13 independent
(except for HLG-240H C type), UL60950-1, UL8750, TUV EN60950-1, IP65 or IP67, J61347-1, J61347-2-13 approved
COLD START 75A(t =570 s measured at 50% I ) at 230VAC
width peak
μ
THD< 20% when output loading 50% at 115VAC/230VAC input and output loading 75% at 277VAC input≧ ≧
TOTAL HARMONIC DISTORTION
MAX. No. of PSUs on 16A
CIRCUIT BREAKER 2 units (circuit breaker of type B) / 4 units (circuit breaker of type C) at 230VAC
Type HL
Bauar
Sicherheit
egel gema
t gepruft
od
be
www.
ID 2000000000
tuv.com
wac g
o s
File Name:HLG-240H-SPEC 2015-08-19


Produkt Specifikationer

Mærke: Velleman
Kategori: Ikke kategoriseret
Model: HLG-240H-24B

Har du brug for hjælp?

Hvis du har brug for hjælp til Velleman HLG-240H-24B stil et spørgsmål nedenfor, og andre brugere vil svare dig




Ikke kategoriseret Velleman Manualer

Velleman

Velleman VMA209 Manual

2 Oktober 2024
Velleman

Velleman VMA329 Manual

10 September 2024
Velleman

Velleman VMA323 Manual

9 September 2024
Velleman

Velleman WSAA108 Manual

3 September 2024
Velleman

Velleman K8042 Manual

3 September 2024
Velleman

Velleman K1823 Manual

3 September 2024
Velleman

Velleman K8101 Manual

3 September 2024
Velleman

Velleman VM167 Manual

3 September 2024
Velleman

Velleman EDU05 Manual

3 September 2024
Velleman

Velleman K2655 Manual

3 September 2024

Ikke kategoriseret Manualer

Nyeste Ikke kategoriseret Manualer

Elektron

Elektron Overbridge Manual

26 November 2024
Elektron

Elektron Sidstation Manual

26 November 2024
SoundTube

SoundTube IPD-RS82-EZ Manual

26 November 2024
Kramer

Kramer 4x1VB Manual

26 November 2024
Kramer

Kramer RC-63A Manual

26 November 2024
SoundTube

SoundTube IPD-HP82-EZ Manual

26 November 2024
Kramer

Kramer RK-KVM-1U-PP3 Manual

26 November 2024
Gioteck

Gioteck VX-2 (PS3) Manual

26 November 2024