MKIS01075-010 Mod. FIUTO
Flush-mounting detector for monitoring air quality by measuring
CO2 equivalent (CO2eq), designed to be installed in closed environments
such as shops, offices, public places, etc.
The output relay is activated when the equivalent CO2 concentration exceeds
the intervention value set with the knob, and can be used, for example,
to activate ventilation units for air exchange. The device performs actions
of 1B type and is intended to operate in environments with pollution degree 2
and overvoltage category III (EN 60730-1).
Code Model Descritpion
VE788100 Fiuto Flush-mounting air quality detector
SAFETY WARNINGS
During product installation and operation it is necessary to observe
the following instructions:
1) The device must be installed by a qualified person, in strict compliance
with the connection diagrams.
2) Do not power or connect the device if any part of it is damaged.
3) After installation, inaccessibility to the connection terminals without
appropriate tools must be guaranteed.
4) The device must be installed and activated in compliance with current electric
systems standards.
5) Before accessing the connection terminals, verify that the leads are not live.
6) In the electrical system of the building where the instrument must be installed,
a protection device from the overcurrents must be present.
TECHNICAL SPECIFICATIONS
• Power supply: 230Vac (-15% ÷ +10%) 50/60Hz
• Absorption: 4VA (0.5W)
• Installation on 3 modules box (503 type)
• Terminals:
– 3 terminals for 1.5 mm2 cables for output relay
– 2 terminals for 1.5 mm2 cables for power supply
• Output: bistable relay 5(3)A / 250 Vac
• Minimum time between a switching and the next one: 1 minute
• Regulation type: on/off with fixed differential of 50 ppm
• Regulation range: 400 ppm÷ 2000 ppm
• 2-position selector switch: always off, automatic
• Operating temperature: 0 ÷ +50°C
• Storage temperature: -10°C ÷ + 60°C
• Operating humidity: 20 ÷ 90% non condensing
• Protection degree: IP40
• Insulation: reinforced among accessible parts (frontal) and all other terminals
• Mechanical locks on the knob to limit the adjustment range
The adapters inside the box allow the monitoring of the following cover plates:
For information about the possibility to adapt the device with different
cover plates from those listed, contact the Technical Service.
* through mount that you can buy on request (code VE767500)
• All the above trademarks are the property of their respective owners
ABB Chiara series
ABB Mylos series
Ave S44 series
Bticino Axolute series
Bticino Axolute Air*
Bticino Light series
Bticino Light tech series
Bticino Living series
Bticino Livinglight series
Bticino Livinglight Air series
Bticino Matix series
Gewiss Chorus series
Vimar Eikon series
Vimar Eikon Evo series
Vimar Idea series
Vimar Plana series
Vimar Arké series
User Manual
FLUSH-MOUNTING AIR QUALITY DETECTOR
Read all instructions carefully
OPERATION
PACKAGE CONTENTS
WIRING DIAGRAMS
ADJUSTABLE COVER PLATES
5
When we talk about air quality, we usually mean the concentration
of carbon dioxide present.
However, it is established that there are, in addition to carbon dioxide (CO
2),
also other gases responsible for the decay of air quality and, consequently,
of the greenhouse effect: methane (CH
4), protoxide nitrogen (N2O),
hydrofluorocarbons (HFC), perfluorocarbons (PFC) and sulfur hexafluoride (SF
6)
Each of these gases contributes to the greenhouse effect with a different
weight (called GWP or Global Warming Potential).
The measurement of all these gases that also takes account
of their specific GWP is called CO
2 equivalent (CO2eq).
WHAT IS CO2 EQUIVALENT
Cover, knob and plastic elements are available in white and anthracite grey colours
Detector
Covers VI plastic
elements
BM plastic
elements
A mount B mount
• Use the selector placed on the front to turn on or off the device:
- position : device off, no regulation0
- position |: device switched on, active regulation.
• Use the knob to set the intervention value.
It’s possible to set values between 400 ppm and 2000 ppm.
When the CO2 concentration present in the room exceeds the set value,
the red led lights up and the relay switches between contacts 1-2.
Note: in order to preserve the life of the system, the minimum time
between a relay switching and the next one is 1 minute. However, the led
status updating is immediate. Therefore, after using the regulation knob, it
is possible to find a momentary discrepancy between what is indicated by
the led and the actual status of the relay.
This condition lasts for up to 1 minute.
Setpoint modification
The device signals the probe error condition with the LED flashing.
In this case the regulation is inhibited and the relay contact remains
between terminals 2 and 3. Contact Vemer Technical Support.
Probe error signal
AIR mount
COM
NO NC
N L
230Va
1 2 3 4 5
• Install the device at a height of about 1.5-2 m from the floor, avoiding positions
with excess or total lack of ventilation. Also make sure that the detector is
installed away from direct radiation, at a distance of at least 30 centimeters
from doors, windows and heat sources. Pay attention that the flow of air that
hits the detector is not obstructed by curtains or wardrobes placed nearby.
Avoid installing the detector in a humid area or with temperatures outside
the operating range. Also avoid positioning the detector near sinks, hobs
or near extractor hoods or vents and, more generally, areas where dirt
and dust could obstruct the slots, preventing correct operation
• The device is sold already mounted with anthracite colour.
To transform it in the white version, remove the knob and the cover, acting
on the hooks placed on the upper and lower side of the device and mount
the cover and the white knob included in the package.
• Make the connections by respecting
the diagrams described in this manual.
• Fix the device inside the 3 modules box
in compliance with the assembly diagrams
described on the back of this instruction sheet.
The accessories for the installation
included in the package allow the mounting
of the plates described in the diagram
“adjustable cover plates”.
INSTALLATION
Reduction of the adjustment range
It is possible to mechanically limit the adjustment range if the device
is installed, for example, in public places or in hotel rooms.
To limit the adjustment range, proceed as follows:
- position the knob in an intermediate value to the desired range
(for example, if the desired adjustment range is 1000-1600 ppm,
bring the knob indicator to the 1300 ppm position)
- remove the knob.
- under the knob there are two rings marked from the words “min”
and “MAX”, respectively for the lower limit and above.
- turn the “min” ring nut clockwise
and position it at the minimum
value of the desired adjustment
range (refer to the ppm values
shown on the cover).
- turn the “MAX” ring nut
anticlockwise and position
it corresponding to the
maximum value of the
desired adjustment range
(refer to the ppm values shown on the cover).
- reposition the knob, making sure that the indicator of the setpoint on
the knob is in the same position as when the knob has been removed.
To remove the setpoint limitation, turn the two ring nuts until the limitation
blocks are in an external position in the range 400 ppm ÷ 2000 ppm.
6
7
REFERENCE STANDARDS
Compliance with Community Directives
2014/35/UE (LVD) and 2014/30/UE (EMCD)
is declared with reference to the following harmonized standards: • EN 60730-2-15
03-2021
Fiuto does not require any particular maintenance.
However, it is necessary to ensure the cleanliness of the slots placed
on the front to ensure proper air flow. Do not use chemicals, polishes
or bleach for cleaning. Simply dust with a damp cloth.
CARE AND MAINTENANCE
After powering up, the device performs the starting phase, which is
necessary to warm up the detector. In this phase, which lasts a total of about
20 seconds, the red led flashes and in the initial 2 seconds the relay switches
twice. In this phase the device does not perform any adjustment and the relay
remains between terminals 2 and 3.
After the starting phase, the device performs the detector self-calibration.
This phase has a variable duration, from about 30 minutes in the best case
(which occurs if the room is well ventilated, with a CO
2eq concentration of
about 400 ppm) up to 8 hours in the worst case. During the self-calibration
phase, the adjustment is still active, even if the CO
2eq measurement carried
out by the detector can take place with lower accuracy.
Note: the starting and self-calibration phase are performed every time
the device is powered.
Start up
Produkt Specifikationer
Mærke: | Vemer |
Kategori: | Detektor |
Model: | Fiuto |
Har du brug for hjælp?
Hvis du har brug for hjælp til Vemer Fiuto stil et spørgsmål nedenfor, og andre brugere vil svare dig
Detektor Vemer Manualer
21 April 2024
Detektor Manualer
- Detektor Bosch
- Detektor Denver
- Detektor Hager
- Detektor Extech
- Detektor Ei Electronics
- Detektor Silverline
- Detektor Skil
- Detektor IFM
- Detektor Pioneer
- Detektor Soler & Palau
- Detektor Garmin
- Detektor Pyle
- Detektor Nedis
- Detektor Abus
- Detektor Edimax
- Detektor Optex
- Detektor Smartwares
- Detektor Kyoritsu
- Detektor Laserliner
- Detektor Black And Decker
- Detektor Dometic
- Detektor Busch-Jaeger
- Detektor Trotec
- Detektor Honeywell
- Detektor Uniden
- Detektor König
- Detektor FireAngel
- Detektor Elro
- Detektor Steinel
- Detektor Powerfix
- Detektor Maginon
- Detektor Tripp Lite
- Detektor Mercury
- Detektor Genie
- Detektor National Geographic
- Detektor Alecto
- Detektor Olympia
- Detektor Techly
- Detektor B/R/K
- Detektor Voltcraft
- Detektor GEV
- Detektor Testboy
- Detektor Cobra
- Detektor Velleman
- Detektor FLIR
- Detektor Perel
- Detektor JUNG
- Detektor Byron
- Detektor ORNO
- Detektor Netatmo
- Detektor Amprobe
- Detektor Fluke
- Detektor Hikvision
- Detektor Sun Joe
- Detektor Gossen
- Detektor Pentatech
- Detektor Testo
- Detektor Grothe
- Detektor Siedle
- Detektor Evolveo
- Detektor Multimetrix
- Detektor Steinberg
- Detektor Axis
- Detektor X-Sense
- Detektor Vimar
- Detektor Dahua Technology
- Detektor ZKTeco
- Detektor Joy-It
- Detektor Nexa
- Detektor HT Instruments
- Detektor AcuRite
- Detektor Toolcraft
- Detektor AstralPool
- Detektor Homematic IP
- Detektor V-TAC
- Detektor Schwaiger
- Detektor Beha-Amprobe
- Detektor Bearware
- Detektor Ferguson
- Detektor Inovonics
- Detektor AngelEye
- Detektor Royal Sovereign
- Detektor Marquant
- Detektor Safescan
- Detektor Xavax
- Detektor X4-Tech
- Detektor FireX
- Detektor DSC
- Detektor Iget
- Detektor Satel
- Detektor Sauter
- Detektor Garrett
- Detektor Kreator
- Detektor Gamma Scout
- Detektor Winland
- Detektor Escort
- Detektor Ebode
- Detektor System Sensor
- Detektor Guardian Avionics
- Detektor Thitronik
- Detektor Whistler
- Detektor Cavius
- Detektor PCE Instruments
- Detektor Flow Smoke Detector
- Detektor Benewake
- Detektor BeeSecure
- Detektor Fisher
- Detektor SureCall
- Detektor STI
- Detektor Schabus
- Detektor Zircon
- Detektor Protector
- Detektor Sanwa
- Detektor Minelab
- Detektor Resideo
- Detektor BlendMount
- Detektor K40
- Detektor Gewiss
- Detektor Seco-Larm
- Detektor Silent Knight
- Detektor S.E. International
- Detektor Rocky Mountain
- Detektor Skyscan
- Detektor Noyafa
- Detektor Gigahertz Solutions
Nyeste Detektor Manualer
21 December 2024
16 December 2024
16 December 2024
16 December 2024
16 December 2024
15 December 2024
15 December 2024
15 December 2024
15 December 2024
14 December 2024