Vemer memo.RC2 Manual


Læs nedenfor 📖 manual på dansk for Vemer memo.RC2 (3 sider) i kategorien Ikke kategoriseret. Denne guide var nyttig for 13 personer og blev bedømt med 4.5 stjerner i gennemsnit af 2 brugere

Side 1/3
=LTLY:W(
0-LS[YL)3=PH*HTW3VUJ
;LS  -H_  
LTHPS!PUMV']LTLYP[^LIZP[L!^^^]LTLYP[
User manual
INFRARED REMOTE CONTROL
Read all instructions carefully
The remote controls of the memo.RC series are electronic devices designed to permit
transfers of programs from and to clocks of the memo series. Thanks to the equipped
infrared interface, it is in fact possible to copy a program generated on a clock onto the
remote control and then transfer it from the remote control to others clock (or to another
remote control).
The memo.RC1 is different from the memo.RC2 in that it only has the loaded language and
Italian cities.
Code Model Description
VE345500 memo.RC1 Infrared remote control for Italy
VE366100 memo.RC2 Infrared remote control for Ita/Eng/Spa/Fra/Deu
TECHNICAL CHARACTERISTICS
Power supply: 2 battery 1,5V (AAA type)
Battery duration ~ 3 years
Multilanguage menu: Italian, English, French, Deutsch, Spanish
Capacity: 126 programs presets
User interface:
- LCD display non-backlit
- Keypad 6 key with text-guide (on display)
Integrated IR interface with 0.5 m capacity with direct sun light (2m when dark)
IR transmission frequency: 31.25 kHz
Software class: A
Operating temperature: 0 ÷ 50°C
Storage temperature: -10 ÷ 70°C
Pollution degree: 2
Protection degree: IP20
INSTALLATION
Insert the batteries in the housing on the back of the
instrument:
remove the cover
insert the batteries, in respect to the polarity shows on
the instrument
secure the cover
At this point, the display segments turn on for a few seconds
and after shows the firmware version.
Then the instrument required the parameters to the correct
operating.
Setting the language (for memo.RC2 only)
5 languages are available:
Italian ´ ´ ´ English Spanish
French ´ German.
Select the language with and “+” “–”.
Confirm with “Ok”.
Setting the date format (for memo.RC2 only)
It is possible to select between the dd-mm-aa and
yy-mm-dd formats.
Select the format with and “+” “–”.
Confirm with “Ok”.
Setting the date
The parameter (year, month, day)
being changed will flash.
Select the desired value with and “+” “–”.
Press “Ok” to confirm and continue
with the next parameter
The insertion sequence is year ´ ´ month day
When the day is being entered, the display will show
a bar with the corresponding day of the week
(1´ Monday, 7 Sunday).´
DIMENSIONS
Setting the time
The parameter (hours, minutes) being changed will flash.
Select the desired value with and “+” “–”.
Press “Ok” to confirm and continue
with the next parameter
The insertion sequence is hours ´ minutes
At this point, the display will show the date, time, day of the week
(in letters on the top row, in numbers at the bottom).
OPERATION
COPY/PASTE mode
This mode allows to:
- transfer a program from a clock to the remote control (copy function)
- transfer the aforementioned program from the remote control to another clock (paste
function)
In this mode, the remote control acts as a transfer bridge for programs between clocks of the
same type.
Note: the copy/paste function can be used also for transferring programs between
remotes. For clarity, the communication will be discussed later between the
remote and watches series memos, speeches are similar still be made in case of
communication between remotes.
In detail, the stages that form this mode are:
COPY
- creation of a program on a clock of the memo series
- activation of the reception on the remote control
- activation of the transmission on the clock
- saving of the transferred program
PASTE
- connection to the network of the clock to be programmed
- resetting of the aforementioned clock and subsequent activation of the reception on the clock
- activation of the transmission on the remote control
- saving of the received program on the clock
Note: during the copy stage, in order to avoid interferences, only one clock must be
in transmission. During the paste stage, instead, it is possible to have more clocks
simultaneously in reception. In this way it is possible to transfer one program on
more clocks at once.
PRE-PROGRAMMING mode (only for memo AST)
This mode allows:
- to generate a program directly on the remote control
- to transfer the aforementioned program to a clock of the seriesmemo AST
INFRARED INTERFACE
The infrared interface allows to swap programs between remote controls and clocks of the memo
series. Hereafter are described the operations for receiving and transmitting a program.
Note: the data package that is sent during a program transfer
is formed, in addition to the program itself, also from other
parameters, such as:
- holiday programs
- pin code
- time change settings
- date format
- language
- geographical coordinates (only memo AST series)
- hour correctons (only memo AST series)
- program settings (only memo DW-Y series)
Note: during the reception and transmission stages keep the remote control aimed at
the display of the clock to be programmed at a distance of about 40 cm.
RECEPTION (copy function)
To receive a program on the remote control it is necessary to:
activate reception onto the remote control
- hold the key for 3 seconds and then confirm with “Rx”
the key“Ok”
activate the transmission on the clock
- hold the key for 3 seconds and then confirm with “Ok”
the key“Ok”
V3IS00554-010-072010
Mod. memo.RC1
memo.RC2
DISPLAY AND KEYPAD DESCRIPTION
Field “text1 / day”
Field “text2 / date”
Field “time”
Field “day of the week”
Field “key functions”
Field “program transfer activated”
Key : menu/esc/check battery activation
Key : confirm value“Ok”
Key : decreases the value/menu back“–”
Key : increases the value/menu forward“+”
Key : trasmission activated“TX
Key : reception activated“RX”
Ok
Ok
Ok
 

Main page
wait for the transfer of the package data.
- on the clock:
the writing appears.
- on the remote:
and the symbol appears and the remote
control emits “beeps”
- at the end the clock display shows the writing scritta
at the end the clock display
shows the writing .
saving the received program.
- the first letter of the name flashes:
1. use the and keys to choose the desired letter“+” “–”
2. confirm with and move on to the next letter“Ok”
Repeat points 1 and 2 until all the letters have been inserted. In case of error in inserting
the name, it is possible to delete the characters inserted until that time pressing the
key. Holding the key for 3 seconds exits without saving. When the last letter
has been inserted, hold the key for 3 seconds. The display shows the name of the “Ok”
program followed by the writing and the number of the program in memory.
The remote control memory allows to memorize up to 126 programs. If the memory is full,
the attempt to insert a new program shows the writing upon the display.
In case the reception is not succesful, the remote control displays the writing
. The causes may be:
- interruption of the physical signal
- excessive distance between the remote control and the clock
- pressure of a key during reception
- time out (maximum 3 minutes)
TRANSMISSION (paste function)
To transmit a program to one or more clocks it is necessary to:
activate reception on the clock (or clocks)
- press the to reset and activate reception“R”
activate transmission on the remote control.
- hold the key for 3 seconds“Tx
choose what program to transmit.
- press the and key to choose the program to “+” “–”
be transferred and confirm with . In order to “Ok”
facilitate the copy-paste operations, upon activation
of the transmission, the last program received by
the remote control is suggested as program to be
transferred.
wait for the transfer of the package data.
- on the remote:
and the symbol appear and the remote
control emits “beeps”
- on the clock:
the writing appears.
- At the end the remote control display shows the
writing while the clock display shows the writing
while the clock display shows
the writing .
In case the transmission is not succesful, the remote control displays the writing
. The causes may be:
- pressure of a key during transmission
- an error linked to the time of the operations to be carried out
PROGRAMS MENU
The program menu allows to:
• display the programs saved on the remote control
• delete a single program or all together
• transfer a program from the remote control to a clock
• create a new program (only for memo AST clocks)
The program menu is organized as follows:


Produkt Specifikationer

Mærke: Vemer
Kategori: Ikke kategoriseret
Model: memo.RC2

Har du brug for hjælp?

Hvis du har brug for hjælp til Vemer memo.RC2 stil et spørgsmål nedenfor, og andre brugere vil svare dig




Ikke kategoriseret Vemer Manualer

Vemer

Vemer TCR Manual

2 Oktober 2024
Vemer

Vemer Set PC RF8 Manual

1 Oktober 2024
Vemer

Vemer ADR-D Vision Manual

22 September 2024
Vemer

Vemer ES Manual

10 September 2024
Vemer

Vemer Thalos RF Manual

3 September 2024
Vemer

Vemer VE 502E Manual

1 September 2024
Vemer

Vemer VE LAN Manual

10 August 2024
Vemer

Vemer LCR048 Manual

10 August 2024
Vemer

Vemer PSR400 Manual

8 August 2024

Ikke kategoriseret Manualer

Nyeste Ikke kategoriseret Manualer

Smeg

Smeg KIT6PX Manual

23 December 2024
Smeg

Smeg KIT6CX Manual

23 December 2024
Smeg

Smeg GTA-6 Manual

23 December 2024