SCHEMI DI COLLEGAMENTO – CONNECTION DIAGRAM - SCHALTPLÄNE
5
Vemer S.p.A.
I - 32032 Feltre (BL) • Via Camp Lonc, 16
e-mail: info@vemer.it - web site: www.vemer.it
V3IS01127-010
Mod. Sens-IR DUO
Manuals
download
PDF
2MODELLI – MODELS – MODELLE
Code DescriptionModel
VE790900 Sens IR DUO Argento
- Rilevatore di movimento con crepuscolare da incasso 2 moduli*
- Flush-mounting 2 modules motion detector with built-in twilight-sensor**
- Unterputz-Bewegungsmelder mit 2 Modulen und eingebautem Dämmerungs***
VE791000 Sens IR DUO Grigio
- Rilevatore di movimento con crepuscolare da incasso 2 moduli*
- Flush-mounting 2 modules motion detector with built-in twilight-sensor**
- Unterputz-Bewegungsmelder mit 2 Modulen und eingebautem Dämmerungs***
VE791100 Sens IR DUO Bianco
- Rilevatore di movimento con crepuscolare da incasso 2 moduli*
- Flush-mounting 2 modules motion detector with built-in twilight-sensor**
- Unterputz-Bewegungsmelder mit 2 Modulen und eingebautem Dämmerungs***
* Inclusi i supporti plastici per adattabilità alla placche delle principali serie civili di ABB, AVE, BTICINO, GEWISS e VIMAR.
** Including plastic supports for adaptability to the plates and the main domestic ranges of ABB, AVE, BTICINO, GEWISS.
*** Einschließlich Kunststoff halterungen zur Anpassung an die Platten und die wichtigsten Haushaltssortimente von
ABB, AVE, BTICINO, GEWISS und VIMAR. and VIMAR.
Code DescriptionModel
VE793200 Sens IR DUO.NOW Nero
- Rilevatore di movimento con crepuscolare da incasso 2 moduli*
- Flush-mounting 2 modules motion detector with built-in twilight-sensor**
- Unterputz-Bewegungsmelder mit 2 Modulen und eingebautem Dämmerungs***
VE793300 Sens IR DUO.NOW Sabbia
- Rilevatore di movimento con crepuscolare da incasso 2 moduli*
- Flush-mounting 2 modules motion detector with built-in twilight-sensor**
- Unterputz-Bewegungsmelder mit 2 Modulen und eingebautem Dämmerungs***
VE791102 Sens IR DUO.NOW Bianco
- Rilevatore di movimento con crepuscolare da incasso 2 moduli*
- Flush-mounting 2 modules motion detector with built-in twilight-sensor**
- Unterputz-Bewegungsmelder mit 2 Modulen und eingebautem Dämmerungs***
*Incluso il supporto plastico per adattabilità alla placca BTICINO Living Now.
** Plastic support for adaptability to BTICINO Living Now plate included.
*** Kunststoff halterung zur Anpassung an die BTICINO Living Now-Platte im Lieferumfang enthalten.
Sens IR DUO.NOW
Code DescriptionModel
VE791001 Sens IR DUO-INT Grigio
- Rilevatore di movimento con crepuscolare da incasso 2 moduli*
- Flush-mounting 2 modules motion detector with built-in twilight-sensor**
- Unterputz-Bewegungsmelder mit 2 Modulen und eingebautem Dämmerungs****
VE791101 Sens IR DUO-INT Bianco
- Rilevatore di movimento con crepuscolare da incasso 2 moduli*
- Flush-mounting 2 modules motion detector with built-in twilight-sensor**
- Unterputz-Bewegungsmelder mit 2 Modulen und
eingebautem Dämmerungs***
* Incluso il supporto plastico per adattabilità alla placche delle principali serie civili di BERKER, BUSCH-JAEGER,
GIRA, JUNG e MERTE
** Including plastic support for adaptability to the plates and the main domestic ranges of BERKER, BUSCH-JAEGER,
GIRA, JUNG e MERTEN
***Einschließlich Kunststoff halterung zur Anpassung an die Platten der wichtigsten Haushaltssortimente von
BERKER, BUSCH-JAEGER, GIRA, JUNG e MERTEN.
Sens IR DUO-INT
Sens IR DUO
3DESCRIZIONE - DESCRIPTION – BESCHREIBUNG
10-2022
NORME DI RIFERIMENTO
La conformità con le Direttive Comunitarie:
2014/35/UE (LVD) 2014/30/UE (EMCD)
è dichiarata in riferimento alle seguenti norme armonizzate: • CEI EN 60669-2-1
ai sensi dell’art. 26 del Decreto Legislativo 14 marzo 2014, n. 49
“Attuazione della direttiva 2012/19/UE
sui rifiuti di apparecchiature elettriche ed elettroniche (RAEE)”
Il simbolo del cassonet to barrato riport ato sullapparecchiatura
o sulla sua confezione indica che il prodotto alla fine
della propria vita utile deve essere raccolto separatamente dagli altri rifiuti.
Lutente dovrà, pertanto, conferire l’apparecchiatura giunta a fine vita
agli idonei centri comunali di raccolta differenziata dei rifiuti elett rotecnici ed elettronici.
In alternativa alla gestione autonoma, è possibile consegnare gratuit amente
l’apparecchiatura che si desidera smaltire al distributore, al momento dellacquisto
di una nuova apparecchiatura di tipo equivalente.
Presso i distributori di prodotti elettronici con superficie di vendita di almeno 400 m
2
è inoltre possibile consegnare gratuitamente, senza obbligo di acquisto,
i prodotti elettronici da smaltire con dimensioni inferiori a 25 cm.
L’adeguata raccolta differenziata per lavvio successivo dell’apparecchiatura dismessa
al riciclaggio, al trattamento e allo smaltimento ambientalmente compatibile
contribuisce ad evitare possibili effetti negativi sull’ambiente e sulla salute e favorisce
il reimpiego e/o riciclo dei materiali di cui è composta l’apparecchiatura.
1Manuale d’Uso
RILEVATORE DI MOVIMENTO DA INCASSO
Leggere attentamente tutte le istruzioni
Sens IR DUO è un rilevatore di movimento crepuscolare da incasso a 2 moduli
che rileva i movimenti dentro il proprio campo d’azione e attiva, per il periodo
di tempo impostato e solo se il livello di luminosi è inferiore alla soglia
impostata, l’impianto di illuminazione. Il dispositivo svolge azioni di tipo 1B ed
è destinato ad operare in ambienti con grado di inquinamento 2 e categoria di
sovratensione III (EN 60730-1).
AVVERTENZE DI SICUREZZA
Durante l’installazione ed il funzionamento del prodotto è necessario rispettare
le seguenti indicazioni:
1) Il prodotto deve essere installato da persona qualificata rispettando
scrupolosamente gli schemi di collegamento.
2) Non alimentare o collegare il dispositivo se qualche parte di esso risulta
danneggiata.
3) Il prodotto deve essere installato e messo in funzione in conformità con la
normativa vigente in materia di impianti elettrici.
4) In caso di malfunzionamento del prodotto non eseguire interventi di riparazione
e contattare direttamente l’assistenza tecnica.
5) Nell’impianto elettrico a monte del prodotto deve essere installato un dispositivo
di protezione contro le sovracorrenti.
6) Dopo l’installazione deve essere garantita l’inacessibilità ai morsetti di
collegamento senza l’uso di appositi utensili.
7) Prima di accedere ai morsetti di collegamento verificare che i conduttori non
siano in tensione.
CARATTERISTICHE TECNICHE
Alimentazione: 230 Vac (-10% ÷ +10%) 50/60 Hz
Assorbimento massimo: 5 VA (1 W)
Uscita: relè NA 5A/250V
Tempo di intervento: 5 secondi (test), 30 secondi ÷ 15 minuti
Luminosità di intervento: 5 ÷ 100 lux
Angolo di rilevamento: 110° a 20°C
Campo di rilevamento: 7 metri a 20°C
Installazione su scatola da incasso con altezza 45 mm (dimensioni: 2 moduli)
Morsettiera per cavi con sezione da 1,5 mm
2
Temperatura di funzionamento: 0°C ÷ 35°C
Temperatura di immagazzinamento: -10°C ÷ 60°C
Umidi di funzionamento: 20÷90% non condensante
Grado di protezione: IP40 (sulle parti accessibili)
Isolamento: rinforzato tra parti accessibili (frontale) e tutti gli altri morsetti
Tipo di azioni: 1B
5A/250V~
NL
REFERENCE STANDARDS
Conformity to the EU directives:
2014/35/EU (LVD) 2014/30/EU (EMCD)
is declared with reference to the following harmonized standard: • EN 60669-2-1
information to users pursuant to art. 14 of the directive
2012/19 / EU of the european parliament and of the council
of 4 july 2012 on waste electrical and electronic equipment (WEEE)
If the crossed-out bin symbol appears on the equipment or packaging,
this means the product must not be included with other general waste
at the end of its working life.
The user must take the worn product to a sorted waste center,
or return it to the retailer when purchasing a new one.
Products for disposal can be consigned free of charge (without any new purchase obligation)
to retailers with a sales area of at least 400 m
2, if they measure less than 25 cm.
An efficient sorted waste collection for the environmentally friendly disposal of the used device, or its
subsequent recycling, helps avoid the potential negative effects on the environment and people’s health,
and encourages the re-use and/or recycling of the construction materials.
1
User manual
FLUSH-MOUNTED MOTION DETECTOR
Read all istructions carefully
Sens IR DUO is a 2-module flush-mounted twilight motion detector that detects
movements within its own range of action and activates the system for the set
period of time and only if the brightness level is lower than the set threshold.
lighting. The device performs type 1B actions and is intended to operate
in environments with pollution degree 2 and overvoltage category III
(EN 60730-1).
SAFETY WARNINGS
During installation and operation of the device it is necessary to comply
with the following instructions:
1) The device must be installed by a qualified person in strict compliance
with the connection diagrams.
2) Do not power on or connect the device if any part of it is damaged.
3) The device must be installed and activated in compliance with current
electris systems standards.
4) In case of product malfunction do not perform repairs and contact technical
assistance directly.
5) An overcurrent protection device must be installed in the electrical system
upstream of the product.
6) After installation, inaccessibility to the connection terminals must be
guaranteed without the use of special tools.
7) Before accessing the connection terminals, verify that the leads
are not live.
TECHNICAL SPECIFICATIONS
Power supply: 230 Vac (-10% ÷ +10%) 50/60 Hz
Max absorption: 5 VA (1 W)
Output: relay NO 5A/250V
Intervention time: 5 seconds (test), 30 seconds ÷ 15 minutes
Intervention brightness: 5 ÷ 100 lux
Detection angle: 110° to 20°C
Detection range: 7 meters at 20°C
Installation on flush-mounted box with 45mm height (dimensions: 2 modules)
Terminal block for cables with max section of 1,5 mm
2
Operating temperature: 0°C ÷ 35°C
Storage temperature: -10°C ÷ 60°C
Operating humidity: 20 ÷ 90% non-condensing
Protection degree: IP40 (on accessible parts)
Insulation: reinforced among accessible parts (front) and all other terminals
Type of actions: 1B
REFERENZSTANDARDS
Die Konformität mit den Gemeinschaftsrichtlinien:
2014/35/UE (LVD) 2014/30/UE (EMCD) wird unter Bezugnahme auf die
folgenden harmonisierten Normen erklärt: • CEI EN 60669-2-1
1Bedienungsanleitung
UNTERPUTZ-BEWEGUNGSMELDER
Alle Anweisungen sorgfältig lesen
Sens IR DUO ist ein 2-Module Unterputz-Dämmerungs-Bewegungsmelder,
der Bewegungen in seinem eigenen Wirkungsbereich erkennt und das
System für die eingestellte Zeit und nur dann aktiviert, wenn die Helligkeit
niedriger als die eingestellte Schwelle ist. Das Gerät führt Aktionen des Typs
1B aus und ist für den Betrieb in Umgebungen mit Verschmutzungsgrad 2
und Überspannungskategorie III (EN 60730-1) vorgesehen.
SICHERHEITSHINWEISE
hrend der Installation und des Betriebs des Gerätes ist es notwendig,
sich an die folgenden Anweisungen zu halten:
1) Das Produkt muss von einer qualifizierten Person installiert werden,
die sich strikt an die Schaltpläne lt.
2) Das Gerät nicht versorgen oder verbinden, wenn Teile des Geräts
beschädigt sind.
3) Das Gerät muss gemäß den geltenden Vorschriften für elektrische Anlagen
installiert und in Betrieb genommen werden.
4) Im Falle einer Produktstörung, nicht reparieren und sich direkt an den
technischen Support wenden.
5) In der elektrischen Anlage muss vor dem Zeitschaltthermostat eine
Überstromschutzvorrichtung installiert werden
6) Nach der Installation muss gewährleistet sein, dass die Verbindungsklemmen
ohne die Benutzung von geeigneten Werkzeugen nicht zugänglich sind.
7) Vor dem Zugriff auf die Verbindungsklemmen prüfen, ob die Leiter nicht
unter Spannung stehen.
TECHNISCHE EIGENSCHAFTEN
Versorgung: 230 Vac (-10% ÷ +10%) 50/60 Hz
Maximale Absorption: 5 VA (1 W)
Ausgang: relay NO 5A/250V
Interventionszeit: 5 Sekunden (test), 30 Sekunden ÷ 15 Minuten
Intervention Helligkeit: 5 ÷ 100 lux
Erfassungswinkel: 110° bis 20°C
Erfassungsbereich: 7 Meter bei 20°C
Montage auf Einbaudose mit einer Höhe von 45 mm (Maße: 2 Module)
Anschlussblock für Kabel mit einem maximalen Querschnitt von 1,5 mm
2
Betriebstemperatur : 0°C ÷ 35°C
Speicherungstemperatur : -10°C ÷ 60°C
Betriebsfeuchtigkeit : 20 ÷ 90% keine Kondensbildung
Schutzgrad: IP40 (an zugänglichen Stellen)
Isolierung: Verstärkt zwischen zugänglichen Teilen (vorne) und allen
anderen Klemmen
Art von Aktionen: 1B
Information für die Nutzer gemäß Art. 14 der Richtlinie 2012/19/EU
des Europäischen Parlaments und des Rates vom 4. Juli 2012
über Elektro- und Elektronik-Altgeräte.
Das Symbol der durchgestrichenenlltonne auf dem Gerät
oder seiner Verpackung weist darauf hin, dass das Produkt am Ende seiner
Nutzungsdauer getrennt von den anderen Abfällen zu entsorgen ist.
Nach Ende der Nutzungsdauer obliegt es dem Nutzer, das Produkt in einer
geeigneten Sammelstelle für getrenntellentsorgung zu deponieren oder es
demndler bei Ankauf eines neuen Produkts zu übergeben.
Bei Händlern mit einer Verkaufsfläche von mindestens 400 p1-m2 können
zu entsorgende Produkte mit Abmessungen unter 25 cm kostenlos
und ohne Kaufzwang abgegeben werden.
Die angemessenelltrennung für das dem Recycling, der Behandlung
und der umweltverträglichen Entsorgung zugeführten Gerätes trägt dazu bei,
mögliche negative Auswirkungen auf die Umwelt und die Gesundheit
zu vermeiden und begünstigt den Wiedereinsatz und/oder das Recyceln der
Materialien, aus denen das Gerat besteht.
DIMENSIONI – DIMENSIONS – MASSE
4
Sensore crepuscolare per la misurazione della luminosità
Twilight sensor for brightness measurement
Dämmerungssensor zur Helligkeitsmessung
Sensore di movimento
Motion sensor
Bewegungssensor
Trimmer di regolazione
Adjustment trimmer
Einstelltimer
44
43
43


Produkt Specifikationer

Mærke: Vemer
Kategori: Ikke kategoriseret
Model: Sens IR DUO

Har du brug for hjælp?

Hvis du har brug for hjælp til Vemer Sens IR DUO stil et spørgsmål nedenfor, og andre brugere vil svare dig




Ikke kategoriseret Vemer Manualer

Vemer

Vemer TCR Manual

2 Oktober 2024
Vemer

Vemer Set PC RF8 Manual

1 Oktober 2024
Vemer

Vemer ADR-D Vision Manual

22 September 2024
Vemer

Vemer ES Manual

10 September 2024
Vemer

Vemer Thalos RF Manual

3 September 2024
Vemer

Vemer VE 502E Manual

1 September 2024
Vemer

Vemer VE LAN Manual

10 August 2024
Vemer

Vemer LCR048 Manual

10 August 2024
Vemer

Vemer PSR400 Manual

8 August 2024

Ikke kategoriseret Manualer

Nyeste Ikke kategoriseret Manualer

Smeg

Smeg KIT6PX Manual

23 December 2024
Smeg

Smeg KIT6CX Manual

23 December 2024
Smeg

Smeg GTA-6 Manual

23 December 2024