Vemer Trillo Manual


Læs nedenfor 📖 manual på dansk for Vemer Trillo (3 sider) i kategorien Ikke kategoriseret. Denne guide var nyttig for 4 personer og blev bedømt med 4.5 stjerner i gennemsnit af 2 brugere

Side 1/3
Vemer S.p.A.
I - 32032 Feltre (BL) • Via Camp Lonc, 16
Tel +39 0439 80638 • Fax +39 0439 80619
e-mail: info@vemer.it - web site: www.vemer.it
DIMENSIONS
WIRING DIAGRAMS
DEVICE STATUS
Mod. TRILLO
V3IS00556-101-042016
• The status of the device is segnalated by the bicolor led :
OFF system not fed
BLINKING RED sim not inserted or pin code in activity
FIXED RED GSM field insufficient
FIXED GREEN starting system/network research
BLINKING GREEN connected to GSM network
QUICKLY BLINKING GREEN arriving in command (ring or sms)
GREEN/RED BLINKING programming mode active
QUICKLY BLINKING RED modem error or failure (if still flashing)
BLINKING YELLOW connected to GSM field but low level battery
Note: blinking = 1 lamp / second
quickly blinking = 5 lamps / second
User manual
GSM COMMUNICATION INTERFACE
Read all instructions carefully
Trillo is a device gsm technology based that executes 1B type actions.
It permits the remote management of an electric service by sending sms or ring from your
telephone.
The backup battery permits to the device to operate for an hour in the case of power fail.
SAFETY WARNINGS
During the installation and operation of the device observe the following instructions:
1) The device must be installed by a qualified person
2) The device must be installed and activated in compliance with current electric systems
standards
3) After installation, inaccessibility to the terminals and to the terminal screws that secure
the wires (power supply and relay) without appropriate tools must be granted
4) Do not use the device for purposes other than indicated
5) The device must be installed in a electric closed panel well protected
6) A two-pole disconnect device with a separation of at least 3 mm between contacts shall be
provided as part of the building installation
7) A protection device against over-currents should be installed in the electrical system,
upstream of the device (maximum 16A)
8) Carefully respect the wiring diagrams to install the device
9) Before accessing the connection terminals, verify that the leads are not live
10)
Do not power or connect the device if any part of it is damaged
11)
The use of a GSM device can cause interference with the functioning of electronic devices
non-screened from radiofrequency signals (electromedical devices, pacemakers, hearing
aids etc.)
12)
In case of fault, do not service the device yourself but contact the after-sales service
13)
The device is aimed for use in place with over-voltage category II and pollution degree 2,
as per standards EN 60950-1.
Code Model Description
VE245700 Trillo GSM communication interface 230V ac
TECHNICAL CHARACTERISTICS
Power supply: 230V ac (-15% ÷ +10%) 50/60Hz
Consumption: 4 VA
Connection:
− cables with max 6 mm2 section
Output:
− a bistable relay with exchange contact
− breaking capacity: 8(5)A / 250V ac
− red led for signal output status
Signalling device status:
− multicolour green/red/yellow led (see box “DEVICE STATUS”)
GSM Qual Band module (900-950-1800-1900 MHz)
SMA-F connector for external aerial (included in the box)
You can store up to 100 numbers
Operating temperature: 0 ÷ 50 °C
Operating humidity: 10 ÷ 90% noncondensing
Storage temperature: -10 ÷ +45°C
Protection: IP20/IP40 if correctly installed in an electric closed panel that guarantee IP40
protection level
Insulation class: II
Container: 4 DIN modules
Backup battery capacity: about 1 hour
INSTALLATION
Getting a sim card enabled for phone traffic, with the required pin code and the
answering machine disabled (to disable the pin code, to use a mobile phone and follow the
steps described in the relative user’s guide).
Remove the flip cover of the housing using a screwdriver.
Insert the sim card into the slot (push-push type). The direction of insertion provides that the
bevel of the sim card goes inside in the left.
Attention: ensure the device is switched OFF before inserting/remove the sim card
(see box “TURN ON/OFF DEVICE”).
Fix the cover.
Screw the supplied antenna into its connector on the side of the device.
Note. Ensure that the power cables are disconnected before replace the antenna.
Connect the power and the load as shown in the “wiring diagrams”.
Once the device has been connected, the led will remain green fix for about 30 seconds;
then the led begins to blinking once at second, indicating the correct reception of the
gsm network. If the battery is fully charged, the led will flash yellow.
If this is not the case, see box “Device status”.
STORE ADMIN NUMBER
For the proper functioning of the device it is necessary to set the number admin who has
full control of the device.
-
hold the “set” button for 5 seconds until the led begins to flash alternately red / green
- make a ring with the number you want to set as many admins.
The caller will receive an sms confirmation of activation.
MANAGEMENT ENABLED NUMBERS
Managing user numbers
You can create a phone book containing up to 100 phone numbers (user numbers) the
which may act on the state of relay by sending sms or phone rings.
There are two ways to add a user number:
via phone ring
Hold for 5 seconds the “Set” button until the led begins to flash
alternating red / green.
Make a ring with the number concerned. This number will be inserted
(removed) from the list of user if not present (present) in the phonebook. An sms
confirmation will be sent to caller with an indication of the phrases employed
total available.
via Sms
The number admin can add or remove at any time the user numbers by sending
the following commands:
USERADD [list of numbers to be added]
USERDEL [list of numbers to be removed]
Numbers add / remove should be separated from each other by a empty space.
Edit number admin (for admin only)
The admin number can be changed by sending (from the current admin number) the
following command:
ADMIN [new admin number]
The new admin will receive an sms number to confirm your transaction.
Note. If the number admin lose it, you can change only forcing a reset,
losing all the numbers previously enabled. For avoid having to reload
manually, please refer to “Manage sim card”.
Manage SIM card (for admin only)
The telephone numbers are stored in the enabled device. This implies, in the case
of a reset, the loss of all authorized users. To avoid having manually refresh all the
numbers, you can make a backup copy of the sim card using the following commands:
STORE creates a copy sim card all the numbers saved user
RESTORE restores previously saved with only the numbers STORE
It is therefore recommended that, once empowered all telephone users, perform a
heading backup.
Display stored user (for admin only)
You can view a list of user numbers stored in blocks of 8 with the command:
USERVIEW [begin] where:
[begin] indicates the first memory location to be displayed.
For example, the command USERVIEW 2 will answer as a list of numbers saved in
memory locations 2 through 9.
OPERATION
TURN ON/OFF DEVICE
Trillo can be turn off without unlink the power cables simply pressing for at least 10
seconds for the key “Set” while all leds turn off. During the pression of the key, the output
led blinks quickly and the led blinks green (or yellow) for the first 5 seconds and green/
red for the other 5 seconds.
To turn on the device, press the key “Set”.
COMMANDS
It is possible to work on the output as follows:
with the key present on the front panel
with ring from a certified number
with a sms from a certified number (without password) or not certified number (with
password)
1 2 7 8 9
2
3
0
V
5
0
-
6
0
H
z
OUT
8 A/250 V~
72 6
45
87
0


Produkt Specifikationer

Mærke: Vemer
Kategori: Ikke kategoriseret
Model: Trillo

Har du brug for hjælp?

Hvis du har brug for hjælp til Vemer Trillo stil et spørgsmål nedenfor, og andre brugere vil svare dig




Ikke kategoriseret Vemer Manualer

Vemer

Vemer TCR Manual

2 Oktober 2024
Vemer

Vemer Set PC RF8 Manual

1 Oktober 2024
Vemer

Vemer ADR-D Vision Manual

22 September 2024
Vemer

Vemer ES Manual

10 September 2024
Vemer

Vemer Thalos RF Manual

3 September 2024
Vemer

Vemer VE 502E Manual

1 September 2024
Vemer

Vemer VE LAN Manual

10 August 2024
Vemer

Vemer LCR048 Manual

10 August 2024
Vemer

Vemer PSR400 Manual

8 August 2024

Ikke kategoriseret Manualer

Nyeste Ikke kategoriseret Manualer

Smeg

Smeg KIT6PX Manual

23 December 2024
Smeg

Smeg KIT6CX Manual

23 December 2024
Smeg

Smeg GTA-6 Manual

23 December 2024