Victron BlueSolar MPPT 150 85-Tr Manual
Victron
Solpaneler
BlueSolar MPPT 150 85-Tr
Læs nedenfor 📖 manual på dansk for Victron BlueSolar MPPT 150 85-Tr (103 sider) i kategorien Solpaneler. Denne guide var nyttig for 32 personer og blev bedømt med 4.5 stjerner i gennemsnit af 2 brugere
Side 1/103

Manual
EN
Handleiding
NL
Manuel
FR
Anleitung
DE
Manual
ES
Användarhandbok
SE
Appendix
BlueSolar charge controllers
MPPT 150/45-Tr MPPT 150/45-MC4
MPPT 150/60-Tr MPPT 150/60-MC4
MPPT 150/70-Tr MPPT 150/70-MC4
MPPT 150/85-Tr MPPT 150/85-MC4
MPPT 150/100-Tr MPPT 150/100-MC4

1
EN NL FR DE ES SE Appendix
1. General Description
1.1 Ultra-fast Maximum Power Point Tracking (MPPT)
Especially in case of a clouded sky, when light intensity is
changing continuously, an ultra fast MPPT controller will
improve energy harvest by up to 30% compared to PWM charge
controllers and by up to 10% compared to slower MPPT
controllers.
1.2 Advanced Maximum Power Point Detection in case of
partial shading conditions
If partial shading occurs, two or more maximum power points
may be present on the power-voltage curve.
Conventional MPPTs tend to lock to a local MPP, which may not
be the optimum MPP.
The innovative BlueSolar algorithm will always maximize energy
harvest by locking to the optimum MPP.
1.3 Outstanding conversion efficiency
No cooling fan. Maximum efficiency exceeds 98%. Full output
current up to 40°C (104°F).
1.4 Extensive electronic protection
Over-temperature protection and power derating when
temperature is high.
PV short circuit and PV reverse polarity protection.
PV reverse current protection.
1.5 Internal temperature sensor
Compensates absorption and float charge voltages for
temperature.
1.6 Automatic battery voltage recognition
The controllers will automatically adjust to a 12V, 24V or a 48V
system one time only. If a different system voltage is required at
a later stage, it must be changed manually, for example with the
Bluetooth app, see section 1.10.

4
2. IMPORTANT SAFETY INSTRUCTIONS
SAVE THESE INSTRUCTIONS - This manual contains
important instructions that shall be followed during
installation and maintenance.
● Please read this manual carefully before the product is
installed and put into use.
● This product is designed and tested in accordance with
international standards. The equipment should be used for the
designated application only.
● Install the product in a heatproof environment. Ensure
therefore that there are no chemicals, plastic parts, curtains or
other textiles, etc. in the immediate vicinity of the equipment.
● The product is not allowed to be mounted in a user accessible
area.
● Ensure that the equipment is used under the correct operating
conditions. Never operate it in a wet environment.
● Never use the product at sites where gas or dust explosions
could occur.
● Ensure that there is always sufficient free space around the
product for ventilation.
● Refer to the specifications provided by the manufacturer of the
battery to ensure that the battery is suitable for use with this
product. The battery manufacturer's safety instructions should
always be observed.
● Protect the solar modules from incident light during
installation, e.g. cover them.
● Never touch uninsulated cable ends.
● Use only insulated tools.
● Connections must always be made in the sequence described
in section 3.5.
● The installer of the product must provide a means for cable
strain relief to prevent the transmission of stress to the
connections.
Danger of explosion from sparking
Danger of electric shock

5
EN NL FR DE ES SE Appendix
● In addition to this manual, the system operation or service
manual must include a battery maintance manual applicable to
the type of batteries used.
● Use flexible multistranded copper cable for the battery and PV
connections.
The maximum diameter of the individual strands is
0,4mm/0,125mm² (0.016 inch/AWG26).
A 25mm² cable, for example, should have at least 196 strands
(class 5 or higher stranding according to VDE 0295, IEC 60228
and BS6360).
An AWG2 gauge cable should have at least 259/26 stranding
(259 strands of AWG26).
Maximum operating temperature: ≥ 90°C.
Example of suitable cable: class 5 “Tri-rated” cable (it has three
approvals: American (UL), Canadian (CSA) and British (BS))
In case of thicker strands the contact area will be too small
and the resulting high contact resistance will cause severe
overheating, eventually resulting in fire.
● The grounding terminal is located in the wiring compartment
and is identified by the symbol below:
Produkt Specifikationer
Mærke: | Victron |
Kategori: | Solpaneler |
Model: | BlueSolar MPPT 150 85-Tr |
Har du brug for hjælp?
Hvis du har brug for hjælp til Victron BlueSolar MPPT 150 85-Tr stil et spørgsmål nedenfor, og andre brugere vil svare dig
Solpaneler Victron Manualer

25 August 2024

24 August 2024

24 August 2024

24 August 2024

24 August 2024

24 August 2024

24 August 2024

24 August 2024

24 August 2024

24 August 2024
Solpaneler Manualer
Nyeste Solpaneler Manualer

28 Juni 2024

28 Juni 2024

28 Juni 2024

28 Juni 2024