Victron BlueSolar PWM-Light 12 24V-20A Manual

Victron Batterioplader BlueSolar PWM-Light 12 24V-20A

Læs nedenfor 📖 manual på dansk for Victron BlueSolar PWM-Light 12 24V-20A (1 sider) i kategorien Batterioplader. Denne guide var nyttig for 22 personer og blev bedømt med 4.5 stjerner i gennemsnit af 2 brugere

Side 1/1
BlueSolar PWM Light Charge Controller 12/24V
(with light turn-off timer)
Victron Energy bv / De Paal 35 / 1351 JG ALMERE / The Netherlands
Phone: (+31) (0)36 535 97 00 / Fax: (+31) (0)36 535 97 40 / www.victronenergy.com / e-mail: sales@victronenergy.com
Revision : Rev 07
Date : 02-05-2017
1. DESCRIPTION
Programmable load output with lighting control mode.
Three stage battery charging (bulk absorption float).
Protected against over current.
Protected against short circuit.
Protected against reverse polarity connection of the battery or solar array.
Low voltage load disconnect.
Easy to set up thanks to two digit seven segment display.
2. INSTALLATION
The display will show a ‘’12’’ if the Controller detects a 12V battery, and a “24” if
it detects a 24V battery
Do not exceed Solar and Load ratings
3. LED INDICATORS
Green LED:
Off: No sunlight or not enough sunlight. Charger off.
Fast flashing: Bulk charge.
On: Absorption charge.
Slow flashing: Float charge.
LED=Green: battery fully charged (> 12,7V)
LED=Orange: battery ok (12,4V - 12,7V)
LED=Red: battery low (11,2V - 12,4V)
LED=Flashing Red: battery fully discharged (< 11,2V)
(load output cut off level: 11,2V)
LED=ON: load output is on.
LED=OFF: load output is off.
LED=Slow flashing: Overload.
LED=Fast flashing: Short Circuit
Please note:
1. The load output will cut off in case of over load or short circuit. The load output
will attempt to restart after 30 seconds.
2. After over discharge, the load will reconnect automatically when the battery is
recharged to 13,1V / 26,2V.
3. After over discharge, the load can be reconnected manually by pressing the
on/off push button, if the battery voltage exceeds 12,6V / 25,2V.
4. SETTING THE LOAD OUTPUT
4.1 Settings
4.2 Settings description
0 Charger only
The load output is switched off permanently.
1-13 Light control + delay
The load output automatically turns on after sunset (array voltage < 4V) and the
built-in timer starts counting.
When the timer reaches the set time, or when the low voltage limit is reached,
the load output will turn off.
H Manual
The load output can be turned on and off manually with the push button.
(low voltage shutdown remains active)
C Load output controlled by battery voltage only
Load disconnect and load reconnect will be based only on battery voltage, see
section 3
L Dusk to dawn mode
Turn on delay (array voltage < 4V): 10 seconds.
Turn off delay (array voltage > 4V): 1 minute.
No timer function.
d Debug mode
Same as L mode but without delay of 10s/1min
5. SPECIFICATIONS
BlueSolar PWM-Light 12/24-5 12/24-10 12/24-20 12/24-30
Battery Voltage 12/24V with automatic system voltage detection*
Rated charge current 5 A 10 A 20 A 30 A
Recommended solar array
36 cell for 12 V / 72 cell for 24 V
Automatic low voltage load
disconnect Yes
Maximum solar voltage 28 V for a 12 V system and 55 V for a 24 V system (1)
Self-consumption < 10 mA
Overload protection
Shut down after 60 s in case of 130% load
Shut down after 5 s in case of 160% load
Short circuit: immediate shut down
Grounding Common positive
Operating temp. range -20 to +50°C (full load)
Humidity (non condensing) Max 95 %
Settings
Charge voltage 'absorption' 14.2 V / 28,4 V
Charge voltage 'float' 13.8 V / 27,6 V
Load disconnect 11,2V / 22,4V
Load reconnect 12,6V / 25,2V (manual)
13,1V / 26,2V (automatic)
Enclosure
Protection class IP20
Terminal size 5 mm² / AWG10
Weight 0,13 kg 0,15 kg
Dimension (h x w x d) 70 x 133 x 33,5 mm (2.8 x 5.3 x 1.3 inch)
Mounting Vertical wall mount Indoor only
Humidity (non condensing) Max. 95%
Operating temperature -20°C to +50°C (full load)
Cooling Natural convection
Standards
Safety IEC 62109-1
EMC EN 61000-6-1, EN 61000-6-3, ISO 7637-2
1) For 12V use 36 cell solar panels
For 24V use 72 cell solar panels
or 2x 36 cell in series
2) The controller switches to the lower float
voltage level 2 hours after the absorption voltage
has been reached.
Whenever the battery voltage becomes lower
than 13 V, a new charge cycle is triggered.
0 Load output permanently off 9
Load output turned on during 9
hours after sunset
1
Load output turned on during 1
hour after sunset
10
Load output turned on during 10
hours after sunset
2
Load output turned on during 2
hours after sunset
11
Load output turned on during 11
hours after sunset
3
Load output turned on during 3
hours after sunset
12
Load output turned on during 12
hours after sunset
4
Load output turned on during 4
hours after sunset
13
Load output turned on during 13
hours after sunset
5
Load output turned on during 5
hour after sunset
H Manual load control
6
Load output turned on during 6
hours after sunset
C
Load output controlled by battery
voltage only
7
Load output turned on during 7
hours after sunset
L Dusk to dawn mode
8
Load output turned on during 8
hours after sunset
d Debug mode
Always connect the batteries first, in order to allow the
Controller to recognize system voltage
Use a 12V (36 cells) solar array for a 12V battery system.
Use a 24V (72 cells) solar array for a 24V battery system.


Produkt Specifikationer

Mærke: Victron
Kategori: Batterioplader
Model: BlueSolar PWM-Light 12 24V-20A

Har du brug for hjælp?

Hvis du har brug for hjælp til Victron BlueSolar PWM-Light 12 24V-20A stil et spørgsmål nedenfor, og andre brugere vil svare dig




Batterioplader Victron Manualer

Batterioplader Manualer

Nyeste Batterioplader Manualer

Einhell

Einhell BT-BC-12 D-SE Manual

23 November 2024
Huslog

Huslog OW-3912 Manual

21 November 2024
SWIT

SWIT S-3822S Manual

20 November 2024
SWIT

SWIT S-3602C Manual

20 November 2024
Celly

Celly PC2TC20WLIGHTCA Manual

20 November 2024
Celly

Celly PC2TCUSBA20WWH Manual

20 November 2024
Celly

Celly PC2TC20WUSBCCAB Manual

20 November 2024
Celly

Celly GHOSTSUPERMAGCH Manual

19 November 2024