EasySolar
12 | 1600 | 70-16 230V MPPT 100 | 50
24 | 1600 | 40-16 230V MPPT 100 | 50
4
Preventing damage due to excessive gassing: the BatterySafe mode
If, in order to quickly charge a battery, a high charge current in combination with a high
absorption voltage has been chosen, the MultiPlus Compact will prevent damage due to
excessive gassing by automatically limiting the rate of voltage increase once the gassing
voltage has been reached.
Less maintenance and aging when the battery is not in use: the Storage mode
The storage mode kicks in whenever the battery has not been subjected to discharge during
24 hours. In the storage mode float voltage is reduced to 2,2V/cell (13,2V for a 12V battery) to
minimize gassing and corrosion of the positive plates. Once a week the voltage is raised back
to the absorption level to ‘equalize’ the battery. This feature prevents stratification of the
electrolyte and sulphation, a major cause of early battery failure.
To increase battery life: temperature compensation
Every MultiPlus Compact comes with a battery temperature sensor. When connected, charge
voltage will automatically decrease with increasing battery temperature. This feature is
especially recommended for sealed batteries and/or when important fluctuations of battery
temperature are expected.
Learn more about batteries and battery charging
To learn more about batteries and charging batteries, please refer to our book ‘Electricity on
Board’ (available free of charge from Victron Energy and downloadable from
www.victronenergy.com). For more information about adaptive charging please look under
Technical Briefs on our website.
2.4 Charge Controller MPPT 100/50
Charge current up to 50A and PV voltage up to 100V
The BlueSolar MPPT 100/50 charge controller is able to charge a lower nominal-voltage
battery from a higher nominal voltage PV array.
Ultra-fast Maximum Power Point Tracking (MPPT)
Especially in case of a clouded sky, when light intensity is changing continuously, an ultra fast
MPPT controller will improve energy harvest by up to 30% compared to PWM charge
controllers and by up to 10% compared to slower MPPT controllers.
Advanced Maximum Power Point Detection in case of partial shading conditions
If partial shading occurs, two or more maximum power points may be present on the power-
voltage curve.
Conventional MPPTs tend to lock to a local MPP, which may not be the optimum MPP.
The innovative BlueSolar algorithm will always maximize energy harvest by locking to the
optimum MPP.
Outstanding conversion efficiency
No cooling fan. Maximum efficiency exceeds 98%. Full output current up to 40°C (104°F).
Flexible charge algorithm
Eight preprogrammed algorithms, selectable with a rotary switch.
Extensive electronic protection
Over-temperature protection and power derating when temperature is high.
17
EN NL FR DE ES IT Appendix
WeakAC
Strong distortion of the input voltage can result in the charger hardly operating or not
operating at all. If WeakAC is set, the charger will also accept a strongly distorted voltage,
at the cost of greater distortion of the input current.
Recommendation: Turn WeakAC on if the charger is hardly charging or not charging at all
(which is quite rare!). Also turn on the dynamic current limiter simultaneously and reduce
the maximum charging current to prevent overloading the generator if necessary.
Not adjustable with DIP switches.
BoostFactor
Change this setting only after consulting with Victron Energy or with an engineer trained
by Victron Energy!
Not adjustable with DIP switches.
Programmable relay
By default, the programmable relay is set as an alarm relay, i.e. the relay will de-energise
in the event of an alarm or a pre-alarm (inverter almost too hot, ripple on the input almost
too high, battery voltage almost too low).
Not adjustable with DIP switches.
Near the connection terminals an LED illuminates when the relay is activated.
VEConfigure
With VEConfigure software the relay can also be programmed for other purposes, for
example to provide a generator starting signal.
5.3 Configuration by computer
All settings can be changed by means of a computer. Some settings can be changed with
DIP switches (see Section 5.2).
For changing settings with the computer, the following is required:
- VEConfigureII software or the appropriate Assistant(s): can be downloaded free of charge at
www.victronenergy.com.
- A RJ45 UTP cable and the MK2.2b RS485-to-RS232 interface. If the computer has no
RS232 connection, but does have USB, a RS232-to-USB interface cable is needed.
Both are available from Victron Energy.
5.3.1 VE.Bus Quick Configure Setup
VE.Bus Quick Configure Setup is a software program with which one Compact unit or
systems with a maximum of three Compact units (parallel or three phase operation) can be
configured in a simple manner. VEConfigureII forms part of this program.
The software free can be downloaded free of charge at www.victronenergy.com.
For connection to the computer, a RJ45 UTP cable and the MK2.2b RS485-to-RS232
interface is required.
If the computer has no RS232 connection, but does have USB, a RS232-to-USB interface
cable is needed. Both are available from Victron Energy.
5.3.2 VE.Bus System Configurator
For configuring advanced applications and/or systems with four or more MultiPlus units,
VE.Bus System Configurator software must be used. The software can be downloaded free
of charge at www.victronenergy.com. VEConfigureII forms part of this program.
28
11. TECHNICAL DATA
EasySolar EasySolar 12/1600/70 EasySolar 24/1600/40
Inverter/charger
PowerControl / PowerAssist
Yes
Transfer switch
16A
INVERTER
Input voltage range 9,5 17V 19 33V
Heavy dutyoutput AC 0 16A
Output AC1, 2, 3 Output voltage: 230VAC ± 2%
Frequency: 50Hz ± 0,1% (1)
Cont. output power at 25 °C (3)
1600VA / 1300W
Cont. output power at 40 °C 1200W
Peak power
3000W
Maximum efficiency
92%
94%
Zero-load power
8W
10W
Zero-load power in search mode
2W
3W
CHARGER
AC Input Input voltage range: 187-265 VAC
Input frequency: 45 65 Hz Power factor: 1
Charge voltage 'absorption' 14,4 / 28,8V
Charge voltage 'float'
13,8 / 27,6V
Storage mode
13,2 / 26,4V
Charge current house battery (4)
70A
40A
Battery temperature sensor
yes
Programmable relay (5) yes
Protection (2)
a - g
Solar Charge Controller
Maximum battery current
50A
Maximum PV power, 6a,b)
700W
1400W
Maximum PV open circuit voltage 100V 100V
Maximum efficiency 98%
Self-consumption
10mA
Charge voltage 'absorption', default
setting
14,4V 28,8V
Charge voltage 'float', default setting 13,8V 27,6V
Charge algorithm
multi-stage adaptive
Temperature compensation
-16mV / °C resp. -32mV / °C
Protection a – g
2
Zorg ervoor dat de apparatuur wordt gebruikt in de juiste omgevingsomstandigheden. Gebruik
het product nooit in een vochtige of stoffige omgeving. Zorg ervoor dat er altijd voldoende vrije
ruimte rondom het product is voor ventilatie en dat de ventilatieopeningen niet worden
geblokkeerd.
Verzeker u ervan dat de vereiste spanning niet hoger is dan de capaciteit van het product.
Vervoer en opslag
Zorg ervoor dat de netspanning en batterijkabels zijn losgekoppeld bij opslag of vervoer van
het product.
Er kan geen aansprakelijkheid worden aanvaard voor transportschade indien de apparatuur
wordt vervoerd in een andere dan de originele verpakking.
Sla het product op in een droge omgeving; de opslagtemperatuur moet tussen de -40°C en
60°C liggen.
Raadpleeg de handleiding van de fabrikant van de accu met betrekking tot vervoer, opslag,
opladen, opnieuw opladen en verwijderen van de accu.
2. BESCHRIJVING
2.1 Algemeen
Alles-in-één stroomoplossing op zonne-energie
De EasySolar combineert een MPPT zonne-laadcontroller, een omvormer/lader en
wisselstroomverdeling in één behuizing.
Het product is eenvoudig te installeren, met een minimum aan bedrading.
Zonne-laadcontroller: BlueSolar MPPT 100/50
Tot drie sets PV-panelen kunnen met drie sets MC4 (PV-ST01) PV-stekkers worden
aangesloten.
Omvormer/lader: MultiPlus Compact 12/1600/70 of 24/1600/40
De MPPT laadcontroller en de EasyPlus omvormer/lader delen de gelijkstroom-accukabels
(meegeleverd). De accu's kunnen worden opgeladen met zonne-energie (MPPT) en/of met
wisselstroom (omvormer/lader) via het elektriciteitsnet of een reeks aggregaten.
Wisselstroomverdeling
De wisselstroomverdeling bestaat uit een aardlekschakelaar (30mA/16A) en vier
wisselstroomuitgangen die van twee 10A- en twee 16A-contactverbrekers zijn voorzien.
Een 16A-uitgang wordt aangestuurd door de wisselstroomingang: deze wordt alleen
ingeschakeld als er wisselstroom beschikbaar is.
PowerAssist
De unieke PowerAssist-technologie beschermt het apparaat of de aggregaatvoeding tegen
overbelasting door, indien nodig, extra omvormvermogen toe te voegen.


Produkt Specifikationer

Mærke: Victron
Kategori: Batterioplader
Model: EasySolar 12 1600 70 MPPT 100 50

Har du brug for hjælp?

Hvis du har brug for hjælp til Victron EasySolar 12 1600 70 MPPT 100 50 stil et spørgsmål nedenfor, og andre brugere vil svare dig




Batterioplader Victron Manualer

Batterioplader Manualer

Nyeste Batterioplader Manualer