Vimar 01488 Manual


Læs nedenfor 📖 manual på dansk for Vimar 01488 (2 sider) i kategorien overvåge. Denne guide var nyttig for 8 personer og blev bedømt med 4.5 stjerner i gennemsnit af 2 brugere

Side 1/2
Viale Vicenza 14
36063 Marostica VI - Italy
www.vimar.com
01488 01 1906
01488
Home automation control device with four push buttons and 240 V~ 50/60Hz
phase-cut dimmer, for incandescent lamps 40-200 W, electronic transformers
40-300 VA 240 V~, 20-150 VA 120 V~, CFL lamps 10-200 W 240 V~, 5-100 W 120
V~, LED lamps 3-200 W 240 V~, 3-100 W 120 V~, visible in darkness with RGB
LEDs with intensity adjustment, to be completed with interchangeable half-but-
ton caps comprising 1 or 2 modules (Eikon) or 2 modules (Arkè or Plana).
The device controls the load directly. It should be used as a double or single push button
depending on the chosen button; the push buttons can also be configured independently
from the dimmer actuation part and can be pressed either at the top or bottom. For the
Eikon and Arkè series, all the button covers, whether from the catalogue or customised,
have symbols which can be backlit with customisable RGB colours.
IMPORTANT: Lamps controllable from a single output must all be the same. All con-
trollable loads must be declared DIMMABLE by the manufacturer. Check the type of
compatible dimming on the lamp packaging: LE (Leading Edge) or TE (Trailing Edge).
Where not specified, the lamp works in both modes, at the discretion of the installer;
choose the type of dimming that ensures the best lamp operation.
FEATURES.
TP BUS Rated supply voltage: 29 V
Mains rated supply voltage: 240 V~, 50 Hz/60 Hz
Absorption from TP bus: 15 mA
Combinable buttons: double or 1 single
Terminals: L, dimmer output, TP bus
Output protected against overload or overcurrent
Max device-load distance 100 m
Operating temperature -5 °C +45 °C (indoor)
IP20 protection degree
Device 01488 should be configured with the Automation Gateway 01410-01411 and
App VIEW Pro.
Not compatible with By-me control panels 21509 and EasyTool Professional.
CONTROLLABLE LOADS.
Controllable loads with load adaptor 01873 connected in parallel:
Controllable RGB loads with load adaptor 01873 connected in parallel:
Plug&Play.
CAUTION: The plug&play mode requires the system to include only plug&play devic-
es and not devices configured in the By-me Plus system.
For operation in Plug&Play mode, only install the 1-module fixed half-button caps on
the device.
In the absence of a configuration, the device is pre-configured as follows:
- briefly press to B turn on the load;
- press for a prolonged time to make the (increase);B upwards adjustment
- briefly press to C turn off the load;
- press for a prolonged time to make the (decrease);C downwards adjustment
- press to send a ” scenario over the bus;F Lights OFF
- press to send a E Lights OFF and roller shutters DOWNscenario over the bus.
When push buttons are pressed, the LEDs are on for 3 s.
Important: in plug&play mode the output does not manage the RGB load
SETTING THE COLOUR OF THE LEDS.
PLUG&PLAY mode.
Procedure activation: simultaneously press push buttons E and F for a prolonged time;
the LEDs will all illuminate in the colour currently set.
E F Colour selection: briefly press push button or to view the next colour.
Saving the colour and exiting the procedure: press push button or for a prolonged F E
time.
Exiting the procedure without saving the colour: automatic after a timeout of 5 s.
B y-me Plus SYSTEM.
The colour is set from the App using the respective menus.
L ED indications
The flashing of any of the LEDs of push buttons B and C is an indication of an alarm.
If both the B and C LEDs are flashing, the electrical power supply output is absent.
Flashing LED C indicates the device’s thermal protection has been triggered.
Check the connections of the corresponding load; also make sure it is not excessive
or unsuitable.
To silence the alarm, briefly press push button B or C (ON/OFF of the corresponding
dimmer).
If the flashing continues, wait for the protection to cool down and then repeat the
command.
OPERATION.
Home automation device acting as a dimmer actuator.
Possible functions of the buttons:
- ON/OFF switch
- roller shutter control
- dimmer control
- scenario activation
Possible functions of the dimmer:
- lights on, lights off and light control
- “flash startmode for CFL lamps
- “ramp” operation
- off delay and “warning” function
- phase control: LE/TE
Possible functions of the dimmer with dedicated RGB loads:
- lights on, lights off and light control
- absolute colour change
- fading show operation
CONFIGURATION.
For the configuration operations, see the By-me Plus system manual.
We recommend you configure the device with the load turned off.
Configuration must be done with the device without the button to be able to press the
configuration push button A.
Functional units: 7 (4 push buttons, 2 rocker buttons and 1 dimmer actuator)
Functional unit selection during configuration:
- press push button and wait 3 s to select the dimmer functional unit;A
- press push button again followed by the desired button ( ) to select the A B C E F, , ,
related push button or rocker button functional unit.
Configuration begins with the turning on of the red LED and ends with it being turned off.D
INSTALLATION RULES.
Installation must be carried out by qualified persons in compliance with the current
regulations regarding the installation of electrical equipment in the country where the
products are installed.
The lamps connected to it must all be the same. White LEDs and RGB LEDs cannot be
controlled simultaneously using the same device.
Not suitable for controlling motors (e.g. fans, ventilators).
Never exceed the rated power.
If installing 2 dimmers in a single box, the controllable loads by each dimmer must be
reduced so that their total does not exceed the maximum power that can be controlled
by a single device.
Overloads, electric arcs and short-circuits cause irreparable damage to the dimmer.
Before installation check the circuit carefully and eliminate any of the above causes.
The dimmer does not have a mechanical 1-way switch in the main circuit and so is not
galvanically separated. The circuit load should be considered always powered.
REGULATORY COMPLIANCE.
LV Directive. EMC directive.
Standards EN 60669-2-5, EN 50491.
REACH (EU) Regulation no. 1907/2006 Art.33. The product may contain traces of lead.
Dimming with leading edge LE
phase control
Dimming with trailing edge TE
phase control
Controllable loads LE TE
40 - 200 W 40 - 200 W
10 - 100 W 10 - 200 W (max 5 lamps) (max 10 lamps)
5 - 100 W 10 - 200 W (max 5 lamps) (max 10 lamps)
40 - 200 VA
(max 3
L
type transformers)
40 - 200 VA
(max 5
C
type transformers)
Controllable loads LE TE
Power supply units
01874-01875
max 10 power supply units Not applicable
Lamps 02662
max 10 lamps Not applicable
RGB lamps 02663
max 10 lamps


Produkt Specifikationer

Mærke: Vimar
Kategori: overvåge
Model: 01488

Har du brug for hjælp?

Hvis du har brug for hjælp til Vimar 01488 stil et spørgsmål nedenfor, og andre brugere vil svare dig




overvåge Vimar Manualer

Vimar

Vimar ZSEM/L24 Manual

3 September 2024
Vimar

Vimar 01488 Manual

17 August 2024
Vimar

Vimar ELVOX 661C Manual

16 August 2024
Vimar

Vimar ELVOX 7549 Manual

16 August 2024
Vimar

Vimar ELVOX 6721 Manual

15 August 2024
Vimar

Vimar 01515.1 Manual

15 August 2024
Vimar

Vimar ELVOX 6720 Manual

14 August 2024
Vimar

Vimar ELVOX 6029 Manual

14 August 2024

overvåge Manualer

Nyeste overvåge Manualer

Bauhn

Bauhn APMTR-0624 Manual

15 Oktober 2024
Acer

Acer K272HUL Dbmidpx Manual

14 Oktober 2024
Acer

Acer EK220QB Manual

13 Oktober 2024
Asus

Asus VP249HR Manual

12 Oktober 2024
Asus

Asus VB178TL Manual

10 Oktober 2024
Asus

Asus VE208N Manual

10 Oktober 2024
Asus

Asus XG258Q Manual

9 Oktober 2024
AOC

AOC C27G2Z3 Manual

7 Oktober 2024